Loading...
HomeMy WebLinkAboutFile Documents.621 W Francis St.0008-2021-BRES (15) aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com web: www.aec-vail.com April 30, 2021 Will Otte Rowland + Broughton 1830 Blake St. Denver, CO 80202 Re: Shuford Residence Will, This document is intended to show compliance of the remodel construction residence located at 621 W. Francis St. in Aspen, CO with the 2015 International Energy Conservation Code (2015 IECC). We propose to follow the prescriptive requirements for alterations approach per sections R503.1-R503.2 of the 2015 IECC. The project is an existing residence with a total floor area of 3,478 sf. For heat load calculations, please refer to the following pages of this document. The heat load calculations are performed using the Carrier Hourly Analysis Program and provides a more detailed and accurate load than Manual J. A dewpoint calculation is not included in these permit documents, as the roof assembly meets the requirements of section R806.5 of the 2015 IRC. Building Envelope The following table lists the mandatory minimum insulation and fenestration requirements for the project in climate zone (7). All new or altered assemblies will meet the following requirements. Fenestration U-factor Skylight U-factor Ceiling R-value Wood frame wall R-value Floor R-value Basement wall R-value Slab R- value Code Minimums 0.28 (1) 0.55 (2) (3) 38 (4) 15/19 10, 4 ft Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7) 2) R-49 cavity insulation in new or insulation sufficient to fill the existing framing cavity 3) U-0.045 in new or insulation sufficient to fill the existing framing cavity 4) Or insulation sufficient to fill the framing cavity, R-19 minimum Sincerely, Mark Sorensen 05/09/2021 8/12/21 MCG/DAM Zone Sizing Summary for Duplex Project Name: 20075 - 621 W Francis St 04/30/2021 Prepared by: AEC 02:48PM Air System Information Air System Name Duplex Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 3495.0 ft² Location Aspen, Colorado Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft² Zone 1 66.7 5406 5406 Aug 1500 57.4 3495.0 1.55 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name / Sensible of Flow Load Area Space Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft² Zone 1 100 - LIVING ROOM B 1 6.4 Nov 1500 470 5.7 530.0 0.89 101 - MUDROOM 1 1.8 Nov 1400 131 2.1 115.0 1.14 102 - LAUNDRY 1 1.4 Jul 1700 104 1.1 55.0 1.88 103 - POWDER B 1 0.1 Jul 1500 10 0.1 20.0 0.48 104 - ENTRY 1 1.4 Jul 1500 155 3.7 105.0 1.48 105 - BEDROOM 1B 1 2.1 Jul 1700 157 2.5 180.0 0.87 106 - BATHROOM 1B 1 0.3 Jul 1500 19 0.1 40.0 0.48 107 - BEDROOM 2B 1 1.9 Jul 1500 140 2.4 180.0 0.78 108 - BATHROOM 2B 1 0.5 Jul 1700 35 0.8 40.0 0.89 109 - MECHANICAL 1 0.5 Jul 1500 75 1.8 55.0 1.37 200 - LIVING ROOM A 1 21.0 Oct 1500 1540 7.8 775.0 1.99 201 - BEDROOM 1A 1 2.5 Jul 1700 182 2.5 180.0 1.01 202 - BATHROOM 1A 1 0.3 Jul 1500 19 0.1 40.0 0.48 203 - BEDROOM 2A 1 2.2 Jul 1500 164 2.4 180.0 0.91 204 - BATHROOM 2A 1 0.5 Jul 1700 36 0.6 40.0 0.89 205 - POWDER A 1 0.3 Sep 1500 19 0.3 25.0 0.77 300 - MASTER BEDROOM 1 14.7 Sep 1400 1079 10.8 380.0 2.84 301 - OFFICE 1 3.3 Jul 1700 244 1.9 75.0 3.25 302 - STAIRS 1 2.7 Jul 1400 198 2.6 145.0 1.37 303 - MASTER BATH 1 5.1 Jul 1500 373 5.7 225.0 1.66 304 - MASTER WC 1 0.2 Jul 1200 15 0.2 20.0 0.74 305 - MASTER CLOSET 1 3.2 Jul 1700 238 2.3 90.0 2.64 Hourly Analysis Program v4.50 Page 1 of 1 05/09/2021 8/12/21 MCG/DAM OUTDOOR TEMPERATURE -15 °F OUTDOOR TEMPERATURE 88 °F INDOOR TEMPERATURE 70 °F INDOOR TEMPERATURE 75 °F TOTAL HEAT LOSS 57,398 BTU/HR SENSIBLE HEAT GAIN 72,478 BTU/HR LATENT HEAT GAIN 2,406 BTU/HR TOTAL HEAT GAIN 74,884 BTU/HR MANUAL J DESIGN CONDITIONS WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS 05/09/2021