HomeMy WebLinkAboutFile Documents.621 W Francis St.0008-2021-BRES (16) aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com web: www.aec-vail.com April 30, 2021 Will Otte Rowland + Broughton 1830 Blake St. Denver, CO 80202 Re: Shuford Residence Garage Will, This document is intended to show compliance of the new construction garage located at 621 W. Francis St. in Aspen, CO with the 2015 International Energy Conservation Code (2015 IECC). We propose to use a prescriptive approach per sections R402.1-R402.3 and R403.2.1 of the 2015 IECC. The project is a new garage built on an existing foundation with a total floor area of 803 sf. For heat load calculations, please refer to the following pages of this document. The heat load calculations are performed using the Carrier Hourly Analysis Program and provides a more detailed and accurate load than Manual J. A dewpoint calculation is not included in these permit documents, as the roof assembly meets the requirements of section R806.5 of the 2015 IRC. Building Envelope The following table lists the mandatory minimum insulation and fenestration requirements for the project in climate zone (7). All new assemblies will meet the following requirements. Fenestration U-factor Skylight U-factor Ceiling R-value Wood frame wall U-value Floor R-value Basement wall R-value Slab R-value Code Minimums 0.28 (1) 0.55 49 0.045 38 (2) 15/19 (3) 10 (4) Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7) 2) Or insulation sufficient to fill the framing cavity, R-19 minimum 3) R-15 continuous insulation on the interior or exterior or R-19 cavity insulation on the interior of the wall. Can be satisfied with R-13 cavity plus R-5 continuous. 4) Existing slab to remain Sincerely, Mark Sorensen 05/09/2021 8/12/21 MCG/DAM Zone Sizing Summary for Garage Project Name: 20075 - 621 W Francis St 04/30/2021 Prepared by: AEC 02:45PM Air System Information Air System Name Garage Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 750.0 ft² Location Aspen, Colorado Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft² Zone 1 11.0 1068 1068 Jul 1600 19.9 750.0 1.42 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name / Sensible of Flow Load Area Space Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft² Zone 1 110 - GARAGE 1 4.3 Jul 1600 569 13.7 435.0 1.31 206 - GARAGE BED 1 5.5 Aug 1500 407 5.4 280.0 1.45 207 - GARAGE BATH 1 1.3 Jul 1700 93 0.9 35.0 2.65 Hourly Analysis Program v4.50 Page 1 of 1 05/09/2021 8/12/21 MCG/DAM OUTDOOR TEMPERATURE -15 °F OUTDOOR TEMPERATURE 88 °F INDOOR TEMPERATURE 70 °F INDOOR TEMPERATURE 75 °F TOTAL HEAT LOSS 19,949 BTU/HR SENSIBLE HEAT GAIN 11,108 BTU/HR LATENT HEAT GAIN 13 BTU/HR TOTAL HEAT GAIN 11,121 BTU/HR MANUAL J DESIGN CONDITIONS WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS 05/09/2021