Loading...
HomeMy WebLinkAboutFile Documents.315 E Dean St.0032-2023-BCOM (10)COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Title: 2021 IECC Project Type:Alteration Location:Aspen, Colorado Climate Zone:7 Construction Site: 315 E Dean St Aspen, Colorado 81611 Owner/Agent: Stephane De Baets Elevated Returns 594 Broadway, suite 1106 New York, New York 11012 stephane@elevatedreturns.com Designer/Contractor: Corrie Kowalinski Rowland+Broughton 1830 Blake Street Denver, Colorado 80202 303-308-1373 corrie.kowalinski@rowlandbroughto n.com Project Information Energy Code: RAKxa Wellness Spa At St. Regis Aspen Building Area Floor Area 1-Spa (Hotel) : Nonresidential 13452 Envelope Assemblies Envelope TBD: No envelope assemblies specified Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 111 ofPage06/08/2023 07/25/2023 jimp COMcheck Software Version COMcheckWeb Interior Lighting Compliance Certificate Project Title: 2021 IECC Project Type:Alteration Construction Site: 315 E Dean St Aspen, Colorado 81611 Owner/Agent: Stephane De Baets Elevated Returns 594 Broadway, suite 1106 New York, New York 11012 stephane@elevatedreturns.com Designer/Contractor: Corrie Kowalinski Rowland+Broughton 1830 Blake Street Denver, Colorado 80202 303-308-1373 corrie.kowalinski@rowlandbroughto n.com Project Information Energy Code: RAKxa Wellness Spa At St. Regis Aspen Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 1-Spa Reception #135 (Hotel:Hotel Lobby)670 0.51 342 2-Retail #134 (Retail:Sales Area)310 1.05 326 3-Shower Vestibule #112 (Common Space Types:Restrooms)58 0.63 37 4-Men's Locker Room #138 (Common Space Types:Locker Room)296 0.52 154 5-Men's Hot Tub #109 (Gymnasium/Fitness Center:Playing Area)386 0.85 328 6-Pool Cave #116 (Gymnasium/Fitness Center:Playing Area)428 0.85 364 7-Women's Hot Tub #118 (Gymnasium/Fitness Center:Playing Area)386 0.85 328 8-Women's Restroom (Common Space Types:Restrooms)242 0.63 152 9-Women's Locker Room (Common Space Types:Locker Room)257 0.52 134 10-Employee #131 (Common Space Types:Laundry/Washing Area)52 0.53 28 11-Men's Restroom #139 (Common Space Types:Restrooms)113 0.63 71 12-Tesla Forming Treatment Room #137 (Healthcare Facility:Exam/Treatment) 124 1.40 174 13-Treatment Room #142 (Healthcare Facility:Exam/Treatment)124 1.40 174 14-Treatment Room #143 (Healthcare Facility:Exam/Treatment)126 1.40 176 15-Treatment Room #145 (Healthcare Facility:Exam/Treatment)126 1.40 176 16-Treatment Room #147 (Healthcare Facility:Exam/Treatment)135 1.40 189 17-Hall #146 (Healthcare Facility:Corridor/Transition >=8 ft wide)278 0.71 197 18-Hall #166 (Healthcare Facility:Corridor/Transition >=8 ft wide)403 0.71 286 19-Lounge #156 (Common Space Types:General Seating Area)998 0.23 230 20-Treatment Room #158 (Healthcare Facility:Exam/Treatment)166 1.40 232 21-Treatment Room #160 (Healthcare Facility:Exam/Treatment)149 1.40 209 22-Treatment Room #161 (Healthcare Facility:Exam/Treatment)142 1.40 199 23-Treatment Room #162 (Healthcare Facility:Exam/Treatment)259 1.40 363 24-Treatment Room #164 (Healthcare Facility:Exam/Treatment)125 1.40 175 25-Treatment Room #165 (Healthcare Facility:Exam/Treatment)142 1.40 199 26-Treatment Room#168 (Healthcare Facility:Exam/Treatment)122 1.40 171 27-Treatment Room #169 (Healthcare Facility:Exam/Treatment)143 1.40 200 28-Treatment Room #170 (Healthcare Facility:Exam/Treatment)137 1.40 192 29-Treatment Room #171 (Healthcare Facility:Exam/Treatment)194 1.40 272 30-Treatment Room #173 (Healthcare Facility:Exam/Treatment)112 1.40 157 Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 112 ofPage06/08/2023 07/25/2023 jimp A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 31-Cryo Therapy Treatment Room #136 (Healthcare Facility:Exam/Treatment) 138 1.40 193 32-Employee #133 (Common Space Types:Office - Open Plan)87 0.61 53 33-Shower Vestibule #125 (Common Space Types:Restrooms)36 0.63 23 6501Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture Spa Reception #135 (Hotel: Hotel Lobby, 670 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 11 20 220 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 74 3 222 LED: P-01: New Pendant Light: LED Other Fixture Unit 60W:7 1 60 60 LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 1 4 4 Retail #134 (Retail: Sales Area, 310 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 25 3 75 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 LED: P-02: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60 LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 3 4 14 LED: UC-02: New Vertical Recessed Light Cha: LED Undercabinet Unit 12W:1 10 12 120 Shower Vestibule #112 (Common Space Types: Restrooms, 58 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4 Men's Locker Room #138 (Common Space Types: Locker Room, 296 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 8 20 160 LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17 LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 6 5 30 Men's Hot Tub #109 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36 LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13 LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17 Pool Cave #116 (Gymnasium/Fitness Center: Playing Area, 428 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: UC-03: New Soffit Perimeter Light: LED Linear 15W:1 64 3 192 Women's Hot Tub #118 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36 LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13 LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17 Women's Restroom (Common Space Types: Restrooms, 242 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 9 20 180 LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9 LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10 Women's Locker Room (Common Space Types: Locker Room, 257 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17 Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 113 ofPage06/08/2023 07/25/2023 jimp E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 4 5 20 Employee #131 (Common Space Types: Laundry/Washing Area, 52 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4 Men's Restroom #139 (Common Space Types: Restrooms, 113 sq.ft.) LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9 LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10 Tesla Forming Treatment Room #137 (Healthcare Facility: Exam/Treatment, 124 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 7 3 21 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 9 15 135 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 2 5 10 Treatment Room #142 (Healthcare Facility: Exam/Treatment, 124 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #143 (Healthcare Facility: Exam/Treatment, 126 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #145 (Healthcare Facility: Exam/Treatment, 126 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 4 3 12 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #147 (Healthcare Facility: Exam/Treatment, 135 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Hall #146 (Healthcare Facility: Corridor/Transition >=8 ft wide, 278 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 6 20 120 LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 1 26 26 Hall #166 (Healthcare Facility: Corridor/Transition >=8 ft wide, 403 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140 LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 3 26 78 Lounge #156 (Common Space Types: General Seating Area, 998 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 21 20 420 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 28 15 420 LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 4 9 LED: P-04: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60 LED: F-04: New Decorative Light: LED Other Fixture Unit 25W:1 1 17 17 Treatment Room #158 (Healthcare Facility: Exam/Treatment, 166 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20 LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #160 (Healthcare Facility: Exam/Treatment, 149 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #161 (Healthcare Facility: Exam/Treatment, 142 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #162 (Healthcare Facility: Exam/Treatment, 259 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 3 5 15 Treatment Room #164 (Healthcare Facility: Exam/Treatment, 125 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20 LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 114 ofPage06/08/2023 07/25/2023 jimp 06/08/2023 07/25/2023 jimp COMcheck Software Version COMcheckWeb Exterior Lighting Compliance Certificate Project Title: 2021 IECC Project Type:Alteration Construction Site: 315 E Dean St Aspen, Colorado 81611 Owner/Agent: Stephane De Baets Elevated Returns 594 Broadway, suite 1106 New York, New York 11012 stephane@elevatedreturns.com Designer/Contractor: Corrie Kowalinski Rowland+Broughton 1830 Blake Street Denver, Colorado 80202 303-308-1373 corrie.kowalinski@rowlandbroughto n.com Project Information Energy Code: RAKxa Wellness Spa At St. Regis Aspen 0 (Unspecified)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / D Tradable Wattage E Allowed Watts (B X C) Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 0 0 350 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power Exterior Lighting TBD: Exterior lighting zone not specified (see project screen) Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 116 ofPage06/08/2023 07/25/2023 jimp 06/08/2023 07/25/2023 jimp Inspection Checklist Requirements: 16.0% were addressed directly in the COMcheck software COMcheck Software Version COMcheckWeb Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2021 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A3.0 Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 118 ofPage06/08/2023 07/25/2023 jimp Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.3. 1 [EL22]1 Spaces required to have light- reduction controls have a manual control that allows the occupant to reduce the connected lighting load in a reasonably uniform illumination pattern >= 50 percent. Complies Does Not Not Observable Not Applicable C405.2.1, C405.2.1. 1 [EL18]1 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, corridors, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable C405.2.1. 2 [EL19]1 Occupancy sensors control function in warehouses: In warehouses, the lighting in aisleways and open areas is controlled with occupant sensors that automatically reduce lighting power by 50% or more within 20 minutes of when the areas are unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. Lights not turned off by occupant sensors is done so by time- switch. Complies Does Not Not Observable Not Applicable C405.2.1. 3 [EL20]1 Occupant sensor control function in open plan office areas: Occupant sensor controls in open office spaces >= 300 sq.ft. have controls 1) configured so that general lighting can be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) general lighting in each zone permitted to turn on upon occupancy in control zone, 3) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 4) are configured so that general lighting power in each control zone is reduced by >= 80% of the full zone general lighting power within 20 minutes of all occupants leaving that control zone. Complies Does Not Not Observable Not Applicable C405.2.2, C405.2.2. 1 [EL21]2 Each area not served by occupancy sensors (per C405.2.1.1) have time- switch controls and functions detailed in sections C405.2.2.1. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 119 ofPage06/08/2023 07/25/2023 jimp Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.4, C405.2.4. 1, C405.2.4. 2 [EL23]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. See code section C405.2.3 Daylight-responsive controls for applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. Complies Does Not Not Observable Not Applicable C405.2.5 [EL27]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable C405.7 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.8 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable C405.9.1, C405.9.2 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable C405.10 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable C405.1.1 [EL30]2 At least 90% of dwelling unit permanently installed lighting shall have lamp efficacy >= 65 lm/W or luminaires with efficacy >= 45 lm/W or comply with C405.2.4 or C405.3. Complies Does Not Not Observable Not Applicable C405.11, C405.11.1 [EL31]2 50% of 15/20 amp receptacles installed in enclosed offices, conference rooms, copy rooms, break rooms, classrooms and workstations and > 25% of branch circuit feeders for modular furniture will have automatic receptacle control in accordance with C405.11.1. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 1110 ofPage06/08/2023 07/25/2023 jimp Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C408.1.1 [FI57]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable C408.2.5 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 1111 ofPage06/08/2023 07/25/2023 jimp