HomeMy WebLinkAboutFile Documents.315 E Dean St.0032-2023-BCOM (10)COMcheck Software Version COMcheckWeb
Envelope Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Location:Aspen, Colorado
Climate Zone:7
Construction Site:
315 E Dean St
Aspen, Colorado 81611
Owner/Agent:
Stephane De Baets
Elevated Returns
594 Broadway, suite 1106
New York, New York 11012
stephane@elevatedreturns.com
Designer/Contractor:
Corrie Kowalinski
Rowland+Broughton
1830 Blake Street
Denver, Colorado 80202
303-308-1373
corrie.kowalinski@rowlandbroughto
n.com
Project Information
Energy Code:
RAKxa Wellness Spa At St. Regis Aspen
Building Area Floor Area
1-Spa (Hotel) : Nonresidential 13452
Envelope Assemblies
Envelope TBD: No envelope assemblies specified
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
111 ofPage06/08/2023
07/25/2023
jimp
COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Construction Site:
315 E Dean St
Aspen, Colorado 81611
Owner/Agent:
Stephane De Baets
Elevated Returns
594 Broadway, suite 1106
New York, New York 11012
stephane@elevatedreturns.com
Designer/Contractor:
Corrie Kowalinski
Rowland+Broughton
1830 Blake Street
Denver, Colorado 80202
303-308-1373
corrie.kowalinski@rowlandbroughto
n.com
Project Information
Energy Code:
RAKxa Wellness Spa At St. Regis Aspen
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
1-Spa Reception #135 (Hotel:Hotel Lobby)670 0.51 342
2-Retail #134 (Retail:Sales Area)310 1.05 326
3-Shower Vestibule #112 (Common Space Types:Restrooms)58 0.63 37
4-Men's Locker Room #138 (Common Space Types:Locker Room)296 0.52 154
5-Men's Hot Tub #109 (Gymnasium/Fitness Center:Playing Area)386 0.85 328
6-Pool Cave #116 (Gymnasium/Fitness Center:Playing Area)428 0.85 364
7-Women's Hot Tub #118 (Gymnasium/Fitness Center:Playing Area)386 0.85 328
8-Women's Restroom (Common Space Types:Restrooms)242 0.63 152
9-Women's Locker Room (Common Space Types:Locker Room)257 0.52 134
10-Employee #131 (Common Space Types:Laundry/Washing Area)52 0.53 28
11-Men's Restroom #139 (Common Space Types:Restrooms)113 0.63 71
12-Tesla Forming Treatment Room #137 (Healthcare
Facility:Exam/Treatment)
124 1.40 174
13-Treatment Room #142 (Healthcare Facility:Exam/Treatment)124 1.40 174
14-Treatment Room #143 (Healthcare Facility:Exam/Treatment)126 1.40 176
15-Treatment Room #145 (Healthcare Facility:Exam/Treatment)126 1.40 176
16-Treatment Room #147 (Healthcare Facility:Exam/Treatment)135 1.40 189
17-Hall #146 (Healthcare Facility:Corridor/Transition >=8 ft wide)278 0.71 197
18-Hall #166 (Healthcare Facility:Corridor/Transition >=8 ft wide)403 0.71 286
19-Lounge #156 (Common Space Types:General Seating Area)998 0.23 230
20-Treatment Room #158 (Healthcare Facility:Exam/Treatment)166 1.40 232
21-Treatment Room #160 (Healthcare Facility:Exam/Treatment)149 1.40 209
22-Treatment Room #161 (Healthcare Facility:Exam/Treatment)142 1.40 199
23-Treatment Room #162 (Healthcare Facility:Exam/Treatment)259 1.40 363
24-Treatment Room #164 (Healthcare Facility:Exam/Treatment)125 1.40 175
25-Treatment Room #165 (Healthcare Facility:Exam/Treatment)142 1.40 199
26-Treatment Room#168 (Healthcare Facility:Exam/Treatment)122 1.40 171
27-Treatment Room #169 (Healthcare Facility:Exam/Treatment)143 1.40 200
28-Treatment Room #170 (Healthcare Facility:Exam/Treatment)137 1.40 192
29-Treatment Room #171 (Healthcare Facility:Exam/Treatment)194 1.40 272
30-Treatment Room #173 (Healthcare Facility:Exam/Treatment)112 1.40 157
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
112 ofPage06/08/2023
07/25/2023
jimp
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
31-Cryo Therapy Treatment Room #136 (Healthcare
Facility:Exam/Treatment)
138 1.40 193
32-Employee #133 (Common Space Types:Office - Open Plan)87 0.61 53
33-Shower Vestibule #125 (Common Space Types:Restrooms)36 0.63 23
6501Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
Spa Reception #135 (Hotel: Hotel Lobby, 670 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 11 20 220
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 74 3 222
LED: P-01: New Pendant Light: LED Other Fixture Unit 60W:7 1 60 60
LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 1 4 4
Retail #134 (Retail: Sales Area, 310 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 25 3 75
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
LED: P-02: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60
LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 3 4 14
LED: UC-02: New Vertical Recessed Light Cha: LED Undercabinet Unit 12W:1 10 12 120
Shower Vestibule #112 (Common Space Types: Restrooms, 58 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4
Men's Locker Room #138 (Common Space Types: Locker Room, 296 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 8 20 160
LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 6 5 30
Men's Hot Tub #109 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36
LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13
LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17
Pool Cave #116 (Gymnasium/Fitness Center: Playing Area, 428 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: UC-03: New Soffit Perimeter Light: LED Linear 15W:1 64 3 192
Women's Hot Tub #118 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36
LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13
LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17
Women's Restroom (Common Space Types: Restrooms, 242 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 9 20 180
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10
Women's Locker Room (Common Space Types: Locker Room, 257 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
113 ofPage06/08/2023
07/25/2023
jimp
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 4 5 20
Employee #131 (Common Space Types: Laundry/Washing Area, 52 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4
Men's Restroom #139 (Common Space Types: Restrooms, 113 sq.ft.)
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10
Tesla Forming Treatment Room #137 (Healthcare Facility: Exam/Treatment, 124 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 7 3 21
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 9 15 135
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 2 5 10
Treatment Room #142 (Healthcare Facility: Exam/Treatment, 124 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #143 (Healthcare Facility: Exam/Treatment, 126 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #145 (Healthcare Facility: Exam/Treatment, 126 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 4 3 12
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #147 (Healthcare Facility: Exam/Treatment, 135 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Hall #146 (Healthcare Facility: Corridor/Transition >=8 ft wide, 278 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 6 20 120
LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 1 26 26
Hall #166 (Healthcare Facility: Corridor/Transition >=8 ft wide, 403 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140
LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 3 26 78
Lounge #156 (Common Space Types: General Seating Area, 998 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 21 20 420
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 28 15 420
LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 4 9
LED: P-04: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60
LED: F-04: New Decorative Light: LED Other Fixture Unit 25W:1 1 17 17
Treatment Room #158 (Healthcare Facility: Exam/Treatment, 166 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #160 (Healthcare Facility: Exam/Treatment, 149 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #161 (Healthcare Facility: Exam/Treatment, 142 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #162 (Healthcare Facility: Exam/Treatment, 259 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 3 5 15
Treatment Room #164 (Healthcare Facility: Exam/Treatment, 125 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
114 ofPage06/08/2023
07/25/2023
jimp
06/08/2023
07/25/2023
jimp
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Construction Site:
315 E Dean St
Aspen, Colorado 81611
Owner/Agent:
Stephane De Baets
Elevated Returns
594 Broadway, suite 1106
New York, New York 11012
stephane@elevatedreturns.com
Designer/Contractor:
Corrie Kowalinski
Rowland+Broughton
1830 Blake Street
Denver, Colorado 80202
303-308-1373
corrie.kowalinski@rowlandbroughto
n.com
Project Information
Energy Code:
RAKxa Wellness Spa At St. Regis Aspen
0 (Unspecified)Exterior Lighting Zone
Allowed Exterior Lighting Power
A
Area/Surface Category
B
Quantity
C
Allowed
Watts /
D
Tradable
Wattage
E
Allowed Watts
(B X C)
Total Tradable Watts (a) =
Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
0
0
350
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
Exterior Lighting TBD: Exterior lighting zone not specified (see project screen)
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
116 ofPage06/08/2023
07/25/2023
jimp
06/08/2023
07/25/2023
jimp
Inspection Checklist
Requirements: 16.0% were addressed directly in the COMcheck software
COMcheck Software Version COMcheckWeb
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2021 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: A3.0
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
118 ofPage06/08/2023
07/25/2023
jimp
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.3.
1
[EL22]1
Spaces required to have light-
reduction controls have a manual
control that allows the occupant to
reduce the connected lighting load in
a reasonably uniform illumination
pattern >= 50 percent.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1,
C405.2.1.
1
[EL18]1
Occupancy sensors installed in
classrooms/lecture/training rooms,
conference/meeting/multipurpose
rooms, copy/print rooms,
lounges/breakrooms, enclosed offices,
open plan office areas, restrooms,
storage rooms, locker rooms,
corridors, warehouse storage areas,
and other spaces <= 300 sqft that are
enclosed by floor-to-ceiling height
partitions. Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1.
2
[EL19]1
Occupancy sensors control function in
warehouses: In warehouses, the
lighting in aisleways and open areas is
controlled with occupant sensors that
automatically reduce lighting power
by 50% or more within 20 minutes of
when the areas are unoccupied. The
occupant sensors control lighting in
each aisleway independently and do
not control lighting beyond the
aisleway being controlled by the
sensor. Lights not turned off by
occupant sensors is done so by time-
switch.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1.
3
[EL20]1
Occupant sensor control function in
open plan office areas: Occupant
sensor controls in open office spaces
>= 300 sq.ft. have controls 1)
configured so that general lighting can
be controlled separately in control
zones with floor areas <= 600 sq.ft.
within the space, 2) general lighting in
each zone permitted to turn on upon
occupancy in control zone, 3)
automatically turn off general lighting
in all control zones within 20 minutes
after all occupants have left the
space, 4) are configured so that
general lighting power in each control
zone is reduced by >= 80% of the full
zone general lighting power within 20
minutes of all occupants leaving that
control zone.
Complies
Does Not
Not Observable
Not Applicable
C405.2.2,
C405.2.2.
1
[EL21]2
Each area not served by occupancy
sensors (per C405.2.1.1) have time-
switch controls and functions detailed
in sections C405.2.2.1.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
119 ofPage06/08/2023
07/25/2023
jimp
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.4,
C405.2.4.
1,
C405.2.4.
2
[EL23]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting. See code section C405.2.3
Daylight-responsive controls for
applicable spaces, C405.2.3.1 Daylight
responsive control function and
section C405.2.3.2 Sidelit zone.
Complies
Does Not
Not Observable
Not Applicable
C405.2.5
[EL27]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
C405.7
[EL26]2
Low-voltage dry-type distribution
electric transformers meet the
minimum efficiency requirements of
Table C405.6.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.8
[EL27]2
Electric motors meet the minimum
efficiency requirements of Tables
C405.7(1) through C405.7(4).
Efficiency verified through certification
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist).
Complies
Does Not
Not Observable
Not Applicable
C405.9.1,
C405.9.2
[EL28]2
Escalators and moving walks comply
with ASME A17.1/CSA B44 and have
automatic controls configured to
reduce speed to the minimum
permitted speed in accordance with
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
Complies
Does Not
Not Observable
Not Applicable
C405.10
[EL29]2
Total voltage drop across the
combination of feeders and branch
circuits <= 5%.
Complies
Does Not
Not Observable
Not Applicable
C405.1.1
[EL30]2
At least 90% of dwelling unit
permanently installed lighting shall
have lamp efficacy >= 65 lm/W or
luminaires with efficacy >= 45 lm/W
or comply with C405.2.4 or C405.3.
Complies
Does Not
Not Observable
Not Applicable
C405.11,
C405.11.1
[EL31]2
50% of 15/20 amp receptacles
installed in enclosed offices,
conference rooms, copy rooms, break
rooms, classrooms and workstations
and > 25% of branch circuit feeders
for modular furniture will have
automatic receptacle control in
accordance with C405.11.1.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
1110 ofPage06/08/2023
07/25/2023
jimp
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3,
C408.2.5.
2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
C408.1.1
[FI57]1
Building operations and maintenance
documents will be provided to the
owner. Documents will cover
manufacturers' information,
specifications, programming
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
Complies
Does Not
Not Observable
Not Applicable
C408.2.5
[FI16]3
Furnished as-built drawings for
electric power systems within 90 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
C408.3
[FI33]1
Lighting systems have been tested to
ensure proper calibration, adjustment,
programming, and operation.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
1111 ofPage06/08/2023
07/25/2023
jimp