HomeMy WebLinkAboutFile Documents.621 W Francis St.0076-2021-BCHO (2)Flare Front High Glass
Metal Frame
Rev 4
Model 30 45 50 60 70 80 100
A- Inch 32 10/16 45 9/16 52 5/16 62 2/16 72 3/16 84 9/16 101 8/16
B- Inch 28 5/16 41 5/16 48 57 13/16 67 11/16 80 1/16 97 3/16
F- Inch 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16
D- Inch 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16
E- Inch 4x6 4x6 5x8 5x8 5x8 5x8 5x8
35
7
"
8
91
2
24
"
61
0
39
7
"
8
10
1
3
2"
51
B
4"
10
2
10
"
25
4
D
F
Telescopic Leg Range
From bottom of glass:10''-19''
9"
22
9A
Fireplace Dimensions
11/22/2021
Appliance Location
4"min.
102 min.
1"min.
25 min.2 "min.
51 min.
Clearances below are to non-combustible materials.
Chimney Installation
Horizontal Termination Vertical Termination
For 5 x 8 vent size create 10'' x 12'' vent termination opening For 5 x 8 vent size create 10'' x 10''
vent termination opening
10"
254
12"
305
10"
254
4"
ma
x
.
10
2
ma
x
.
2"
mi
n
.
51
mi
n
.
10"
25 4
11/22/2021
Flat Vs. L Shape Installation For Flare Front Fireplace
Flat Installation Example L Shape Installation Example
4"
102 Max. Shelf Width
Heat Release and Air Intakes
The following sizes MUST be maintained for the upper heat
release:
For fireplaces sized 80” & 100”–vent area must be at least 200
square inches.
For fireplaces sized 60” & 70” -vent area must be at least 140
square inches.
For fireplace sized 50” and below -vent area must be at least 100
square inches.
The following sizes MUST be maintained for the lower air intake:
For fireplaces sized 80” & 100” –vent area must be at least 100
square inches.
For fireplaces sized 60” & 70” -vent area must be at least 70
square inches.
For fireplaces sized 50” and below -vent area must be at least 50
square inches.
For See Through and Room Definer fireplaces, the air intake
requirements are double.
NOTE: Openings above for Heat Release and Air Intake are
measured for open air space.
NOTE: On all See Through and Room Definer units the air intake
must be doubled 11/22/2021
Metal Framing Dimensions
Rev 04
NOTE: Dimension ‘Y’ uses legs at default lowest height 4” below the unit with glass beginning 10” above the
floor. Increase leg height and Y dimension for higher viewing window.
Z
Y
X
Metal stud with Non-
Combustible Back Wall
Inch 33 10/16 40 6/16
mm 854 1026
Inch 46 9/16 40 6/16
mm 1169 1026
Inch 53 5/16 40 6/16
mm 1354 1026
Inch 63 2/16 40 6/16
mm 1603 1026
Inch 73 3/16 40 6/16
mm 1859 1026
Inch 85 9/16 40 6/16
mm 2173 1026
Inch 102 8/16 40 6/16
mm 2604 1026
30 20 1/16 24 1/16
510 611
X Y Z
Flat Installation Recess Installation ( 4" Max)
50 20 1/16 24 1/16
510 611
45 20 1/16 24 1/16
510 611
70 20 1/16 24 1/16
510 611
60 20 1/16 24 1/16
510 611
100 20 1/16 24 1/16
510 611
80 20 1/16 24 1/16
510 611
11/22/2021
Metal Framing Materials &
Clearances
Rev 04
CLEARANCES TO SIDE AND BACK
11/22/2021