Loading...
HomeMy WebLinkAboutFile Documents.621 W Francis St.0076-2021-BCHO (2)Flare Front High Glass Metal Frame Rev 4 Model 30 45 50 60 70 80 100 A- Inch 32 10/16 45 9/16 52 5/16 62 2/16 72 3/16 84 9/16 101 8/16 B- Inch 28 5/16 41 5/16 48 57 13/16 67 11/16 80 1/16 97 3/16 F- Inch 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 18 9/16 D- Inch 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 18 1/16 E- Inch 4x6 4x6 5x8 5x8 5x8 5x8 5x8 35 7 " 8 91 2 24 " 61 0 39 7 " 8 10 1 3 2" 51 B 4" 10 2 10 " 25 4 D F Telescopic Leg Range From bottom of glass:10''-19'' 9" 22 9A Fireplace Dimensions 11/22/2021 Appliance Location 4"min. 102 min. 1"min. 25 min.2 "min. 51 min. Clearances below are to non-combustible materials. Chimney Installation Horizontal Termination Vertical Termination For 5 x 8 vent size create 10'' x 12'' vent termination opening For 5 x 8 vent size create 10'' x 10'' vent termination opening 10" 254 12" 305 10" 254 4" ma x . 10 2 ma x . 2" mi n . 51 mi n . 10" 25 4 11/22/2021 Flat Vs. L Shape Installation For Flare Front Fireplace Flat Installation Example L Shape Installation Example 4" 102 Max. Shelf Width Heat Release and Air Intakes The following sizes MUST be maintained for the upper heat release: For fireplaces sized 80” & 100”–vent area must be at least 200 square inches. For fireplaces sized 60” & 70” -vent area must be at least 140 square inches. For fireplace sized 50” and below -vent area must be at least 100 square inches. The following sizes MUST be maintained for the lower air intake: For fireplaces sized 80” & 100” –vent area must be at least 100 square inches. For fireplaces sized 60” & 70” -vent area must be at least 70 square inches. For fireplaces sized 50” and below -vent area must be at least 50 square inches. For See Through and Room Definer fireplaces, the air intake requirements are double. NOTE: Openings above for Heat Release and Air Intake are measured for open air space. NOTE: On all See Through and Room Definer units the air intake must be doubled 11/22/2021 Metal Framing Dimensions Rev 04 NOTE: Dimension ‘Y’ uses legs at default lowest height 4” below the unit with glass beginning 10” above the floor. Increase leg height and Y dimension for higher viewing window. Z Y X Metal stud with Non- Combustible Back Wall Inch 33 10/16 40 6/16 mm 854 1026 Inch 46 9/16 40 6/16 mm 1169 1026 Inch 53 5/16 40 6/16 mm 1354 1026 Inch 63 2/16 40 6/16 mm 1603 1026 Inch 73 3/16 40 6/16 mm 1859 1026 Inch 85 9/16 40 6/16 mm 2173 1026 Inch 102 8/16 40 6/16 mm 2604 1026 30 20 1/16 24 1/16 510 611 X Y Z Flat Installation Recess Installation ( 4" Max) 50 20 1/16 24 1/16 510 611 45 20 1/16 24 1/16 510 611 70 20 1/16 24 1/16 510 611 60 20 1/16 24 1/16 510 611 100 20 1/16 24 1/16 510 611 80 20 1/16 24 1/16 510 611 11/22/2021 Metal Framing Materials & Clearances Rev 04 CLEARANCES TO SIDE AND BACK 11/22/2021