HomeMy WebLinkAboutFile Documents.315 E Dean St.0032-2023-BCOM (20)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shallnot relieve the applicant of theirresponsibility to comply with therequirements of the City of AspenMunicipal Code. Pursuant toSec.26.104.050, any permit or approvalissued in error or otherwise not inconformity with the requirements of thisTitle, shall be void. Similarly, any permitor approval issued in reliance upon oras a result of, a materially falsestatement or representation made inthe process of obtaining the permit ordevelopment approval shall, likewise,be void. Any person having received avoid or voidable permit or approvalshall not be relieved from having tocomply with all applicable terms andconditions of this Title and the City shallnot be estopped from fully enforcingsame.
APPLICATION ACCEPTED DATE: 2023-06-21 PERMIT NUMBER: 0032-2023-BCOM
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 315 E DEAN ST UNIT:
PARCEL ID: 273718285032 LEGAL DESCRIPTION: ASPEN RESIDENCE CLUB & HOTEL
OWNER: ASPEN OWNER LLC
PERMIT CONTRACTOR: Ironstar Construction, Inc.
DESCRIPTION OF WORK Interior remodel of spa consisting of new flooring (tile and carpet), new tile on shower floors, new furniture,
new reception desk, new plaster in hot tubs, new sliding doors to oxygen room, some new lighting.
USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? Yes
CLASS OF WORK Commercial FIRE SPRINKLER TYPE
BUILDING TYPE (IRC) REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE COMCheck UA Alternative
OCCUPANCY GROUP (IBC) A-1 WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2021 IEBC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? Yes
READ THIS OR FAIL YOUR INSPECTION!
Dropped Ceilings and Soffits beneath fire rated
assemblies
2021 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
1. Dropped Ceilings & Soffits: If dropped 1 ¾
inches or less, do one of the following:
-Fill spaces with Class A material.
-Fill spaces with inorganic or non-combustible material.
-Fire block 8 feet in all directions.
2. Dropped Ceilings & Soffits: If dropped greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
3. Dropped Ceilings & Soffits below Heavy
Timber T&G ceilings, do all of the following:
-One layer 5/8” type X gypsum board directly
attached with minimum level one finish.
-Drop ceiling according to item 1 or 2 above as
applicable.
(City Policy)
Dwelling Separation Required - 2021 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.
FIRE RATED HATS &
CEILING RADIATION DAMPERS
REQUIRED
Where floor/ceiling or roof/ceiling assemblies
are required to have a fire-resistive rating,
recessed fixtures shall be installed such that
the required fire resistance will not be reduced.
Ducts and air transfer openings penetrating the
ceiling of a fire rated ceiling assembly must be
protected with a listed ceiling radiation damper.
This includes bathroom exhaust fans.
(IBC 714.4.2 & 717.6.2)
Existing Fireplaces and Woodstoves:
-If you propose to alter the firebox of a fireplace or move a
fireplace, it shall be removed or replaced with a gas direct
vent or electric appliance.
-Conversion to or replacement with gas log is prohibited.
-New or replacement gas fireplaces are subject to REMP.
-If you propose to move or alter a woodstove, it shall be
removed or replaced with a department certified woodstove.
IF FRAMING CAVITIES ARE EXPOSED:
QUALITY INSULATION REQUIRED
If finish materials are removed to expose
framing cavities in the thermal envelope,
those cavities must be filled with insulation
installed to Grade I quality standard
(ICC/RESNET 301).
Ordinance 1, 2023
Batts/loose fill: Insulation shall be closely
fitted wiring, pipes, etc. and avoid
substantial gaps, voids or compression. No
more than 2% of the total insulated area
shall be compressed or contain gaps or
voids in the insulation. These areas shall
not be compressed more
than 3/4 inch.
IF YOU EXCEED YOUR APPROVED SCOPE,
YOU COULD TRIGGER ADDITIONAL REQUIREMENTS
If basement walls in the thermal envelope are altered
(removal of finish for example), you must provide the following
basement wall minimum insulation unless you can document
that it is already present:
Residential: R-13 cavity or R-10 continuous
Commercial: R-19 cavity or R-20 continuous
Ordinance 1, 2023
2021 IBC Code References
L 100% of lamps in permanently installed lights must be high efficacy, Ordinance 1, 2023.
AS Access and service space for maintenance required, 2021 IMC 306
CO Carbon monoxide detector required per Aspen Municipal Code 8.15
DE Clothes dryer exhaust, 2021 IMC 504. Makeup air required if over 200 CFM
SE Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, Ordinance 1, 2023
DV Direct vent sealed combustion required, Ordinance 1, 2023
EP Electric panel happy space: 30in x 36in x 78in, not in storage, NEC 110.26
EE Emergency escape and rescue opening required 2021 IBC 1031
ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2021 IMC 501.3.1
GR Guards, 42in min high, 4in max opening. Guards within dwelling unit 36in min high 2021 IBC 1015
HR Handrails 34in-38in high, 2021 IBC 1014
IT Intake openings 10ft from lot line & contaminant sources (vents, streets), 2021 IMC 401.4
MA Make up air required if hood exhausts greater than 400 CFM, 2021 IMC 505.4
V Mechanical ventilation required, Ordinance 1, 2023
F New or replacement fenestration in existing residential buildings shall not exceed 0.28 U-factor, NFRC label required, Ordinance 1, 2023
SG Safety glazing required, 2021 IBC 2406
SA Smoke alarm per NFPA 72 required, 2021 IBC 907.2.11
WFP Window fall protection- operable window less than 24in AFF and greater than 72in above exterior grade: use opening control device listed to ASTM F2090, 2021 IBC 1015.8
09/11/2023
jimp
May 17, 2023
Joel Hocknell
Aspen Owner LLC
315 E Dean St
Aspen, CO 81611
joelhocknell@gmail.com
RE: St Regis Spa Remodel
315 E Dean Street
Aspen, Colorado 81611
ESD Project #: 23.068C
Joel,
As requested, we have been engaged to review the potential structural impact of the proposed remodel at the
location noted above. We have received the Spa Demolition Plan D2.1 by Rowland Broughton, dated March 7,
2023. The current proposed scope of work includes modifications to interior walls.
Once demolition can begin, the wall and ceiling finishes in these areas, shall be at least partially removed in
order to verify the potential effects to the existing structure. We shall be contacted to visually observe the
conditions and will then work to define the structural impact of the proposed. This shall be done prior to
proceeding with the removal or modification of any framing members, while also allowing sufficient time for the
scope of structural engineering to be defined and completed. Please note, no interior partition walls nor ceiling
framing shall be removed or modified prior to our observation.
Please note that verifications and subsequent recommendations may have a significant impact on the project
direction and schedule. Should you have any further questions regarding this matter, please feel free to contact
our office. We look forward to working with you through the completion of your remodel.
Sincerely,
Evolve Structural Design LLC Reviewed By:
Steve Edmiston, P.E., S.E.
Principal
Chris Bridges, E.I.
Project Engineer
05/17/2023
06/08/2023
07/20/2023
jimp
Page 1 of 2
St. Regis Aspen Spa Remodel
Project: 22209.00 – RAKxa Aspen Spa
Subject: Fire Protection Letter
Date: 19 April 2023
To whom this may concern,
This letter is to state that there will be no damage to the existing fire rated assemblies as part of the Interior
remodel for St Regis Spa.
Property: St. Regis Hotel
Area of Remodel: Lower Level Spa
Construction Type: 1A
The proposed spa remodel will include minor demolition on non-bearing interior partitions and new finishes
throughout including the replacement of existing decorative lighting in ceiling. Per IBC Table 601,a Type 1A
construction requires no fire rating for nonbearing interior partitions but does require floor assemblies to be 2
hour fire rated. The existing floor/ceiling assembly as seen in previous remodel construction document plan sets,
and as shown below, shows the assembly as a 2 Hour fire rated post tension concrete slab.
Existing Floor/Ceiling Assembly Detail:
06/08/2023
07/25/2023
jimp
Page 2 of 2
Reference Table 601:
The interior remodel of the Spa is proposing replacement of finishes and decorative light fixtures, in their current
location. Both of these will affect the finish layer of the floor/ ceiling assembly but not penetrate the existing
concrete assembly.
Please reach out with any questions.
Sincerely,
Corrie Kowalinski
Corrie.kowalinski@rowlandbroughton.com
(970)429-8704 Ext 207
06/08/2023
07/25/2023
jimp
FIRE
SPRINKLERS
REQUIRED
The City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Construction Site:
315 E Dean St
Aspen, Colorado 81611
Owner/Agent:
Stephane De Baets
Elevated Returns
594 Broadway, suite 1106
New York, New York 11012
stephane@elevatedreturns.com
Designer/Contractor:
Corrie Kowalinski
Rowland+Broughton
1830 Blake Street
Denver, Colorado 80202
303-308-1373
corrie.kowalinski@rowlandbroughto
n.com
Project Information
Energy Code:
RAKxa Wellness Spa At St. Regis Aspen
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
1-Spa Reception #135 (Hotel:Hotel Lobby)670 0.51 342
2-Retail #134 (Retail:Sales Area)310 1.05 326
3-Shower Vestibule #112 (Common Space Types:Restrooms)58 0.63 37
4-Men's Locker Room #138 (Common Space Types:Locker Room)296 0.52 154
5-Men's Hot Tub #109 (Gymnasium/Fitness Center:Playing Area)386 0.85 328
6-Pool Cave #116 (Gymnasium/Fitness Center:Playing Area)428 0.85 364
7-Women's Hot Tub #118 (Gymnasium/Fitness Center:Playing Area)386 0.85 328
8-Women's Restroom (Common Space Types:Restrooms)242 0.63 152
9-Women's Locker Room (Common Space Types:Locker Room)257 0.52 134
10-Employee #131 (Common Space Types:Laundry/Washing Area)52 0.53 28
11-Men's Restroom #139 (Common Space Types:Restrooms)113 0.63 71
12-Tesla Forming Treatment Room #137 (Healthcare
Facility:Exam/Treatment)
124 1.40 174
13-Treatment Room #142 (Healthcare Facility:Exam/Treatment)124 1.40 174
14-Treatment Room #143 (Healthcare Facility:Exam/Treatment)126 1.40 176
15-Treatment Room #145 (Healthcare Facility:Exam/Treatment)126 1.40 176
16-Treatment Room #147 (Healthcare Facility:Exam/Treatment)135 1.40 189
17-Hall #146 (Healthcare Facility:Corridor/Transition >=8 ft wide)278 0.71 197
18-Hall #166 (Healthcare Facility:Corridor/Transition >=8 ft wide)403 0.71 286
19-Lounge #156 (Common Space Types:General Seating Area)998 0.23 230
20-Treatment Room #158 (Healthcare Facility:Exam/Treatment)166 1.40 232
21-Treatment Room #160 (Healthcare Facility:Exam/Treatment)149 1.40 209
22-Treatment Room #161 (Healthcare Facility:Exam/Treatment)142 1.40 199
23-Treatment Room #162 (Healthcare Facility:Exam/Treatment)259 1.40 363
24-Treatment Room #164 (Healthcare Facility:Exam/Treatment)125 1.40 175
25-Treatment Room #165 (Healthcare Facility:Exam/Treatment)142 1.40 199
26-Treatment Room#168 (Healthcare Facility:Exam/Treatment)122 1.40 171
27-Treatment Room #169 (Healthcare Facility:Exam/Treatment)143 1.40 200
28-Treatment Room #170 (Healthcare Facility:Exam/Treatment)137 1.40 192
29-Treatment Room #171 (Healthcare Facility:Exam/Treatment)194 1.40 272
30-Treatment Room #173 (Healthcare Facility:Exam/Treatment)112 1.40 157
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
112 ofPage06/08/2023
07/25/2023
jimp
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
31-Cryo Therapy Treatment Room #136 (Healthcare
Facility:Exam/Treatment)
138 1.40 193
32-Employee #133 (Common Space Types:Office - Open Plan)87 0.61 53
33-Shower Vestibule #125 (Common Space Types:Restrooms)36 0.63 23
6501Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
Spa Reception #135 (Hotel: Hotel Lobby, 670 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 11 20 220
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 74 3 222
LED: P-01: New Pendant Light: LED Other Fixture Unit 60W:7 1 60 60
LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 1 4 4
Retail #134 (Retail: Sales Area, 310 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 25 3 75
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
LED: P-02: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60
LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 3 4 14
LED: UC-02: New Vertical Recessed Light Cha: LED Undercabinet Unit 12W:1 10 12 120
Shower Vestibule #112 (Common Space Types: Restrooms, 58 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4
Men's Locker Room #138 (Common Space Types: Locker Room, 296 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 8 20 160
LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 6 5 30
Men's Hot Tub #109 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36
LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13
LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17
Pool Cave #116 (Gymnasium/Fitness Center: Playing Area, 428 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: UC-03: New Soffit Perimeter Light: LED Linear 15W:1 64 3 192
Women's Hot Tub #118 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36
LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13
LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17
Women's Restroom (Common Space Types: Restrooms, 242 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 9 20 180
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10
Women's Locker Room (Common Space Types: Locker Room, 257 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
113 ofPage06/08/2023
07/25/2023
jimp
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 4 5 20
Employee #131 (Common Space Types: Laundry/Washing Area, 52 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4
Men's Restroom #139 (Common Space Types: Restrooms, 113 sq.ft.)
LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9
LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10
Tesla Forming Treatment Room #137 (Healthcare Facility: Exam/Treatment, 124 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 7 3 21
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 9 15 135
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 2 5 10
Treatment Room #142 (Healthcare Facility: Exam/Treatment, 124 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #143 (Healthcare Facility: Exam/Treatment, 126 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #145 (Healthcare Facility: Exam/Treatment, 126 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 4 3 12
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #147 (Healthcare Facility: Exam/Treatment, 135 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Hall #146 (Healthcare Facility: Corridor/Transition >=8 ft wide, 278 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 6 20 120
LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 1 26 26
Hall #166 (Healthcare Facility: Corridor/Transition >=8 ft wide, 403 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140
LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 3 26 78
Lounge #156 (Common Space Types: General Seating Area, 998 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 21 20 420
LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 28 15 420
LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 4 9
LED: P-04: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60
LED: F-04: New Decorative Light: LED Other Fixture Unit 25W:1 1 17 17
Treatment Room #158 (Healthcare Facility: Exam/Treatment, 166 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #160 (Healthcare Facility: Exam/Treatment, 149 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #161 (Healthcare Facility: Exam/Treatment, 142 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Treatment Room #162 (Healthcare Facility: Exam/Treatment, 259 sq.ft.)
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 3 5 15
Treatment Room #164 (Healthcare Facility: Exam/Treatment, 125 sq.ft.)
LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20
LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18
LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5
Project Title:
Data filename:
RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date:
114 ofPage06/08/2023
07/25/2023
jimp
06/08/2023
07/25/2023
jimp