Loading...
HomeMy WebLinkAboutFile Documents.315 E Dean St.0032-2023-BCOM (20)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shallnot relieve the applicant of theirresponsibility to comply with therequirements of the City of AspenMunicipal Code. Pursuant toSec.26.104.050, any permit or approvalissued in error or otherwise not inconformity with the requirements of thisTitle, shall be void. Similarly, any permitor approval issued in reliance upon oras a result of, a materially falsestatement or representation made inthe process of obtaining the permit ordevelopment approval shall, likewise,be void. Any person having received avoid or voidable permit or approvalshall not be relieved from having tocomply with all applicable terms andconditions of this Title and the City shallnot be estopped from fully enforcingsame. APPLICATION ACCEPTED DATE: 2023-06-21 PERMIT NUMBER: 0032-2023-BCOM COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 315 E DEAN ST UNIT: PARCEL ID: 273718285032 LEGAL DESCRIPTION: ASPEN RESIDENCE CLUB & HOTEL OWNER: ASPEN OWNER LLC PERMIT CONTRACTOR: Ironstar Construction, Inc. DESCRIPTION OF WORK Interior remodel of spa consisting of new flooring (tile and carpet), new tile on shower floors, new furniture, new reception desk, new plaster in hot tubs, new sliding doors to oxygen room, some new lighting. USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Commercial FIRE SPRINKLER TYPE BUILDING TYPE (IRC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE COMCheck UA Alternative OCCUPANCY GROUP (IBC) A-1 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2021 IEBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? Yes READ THIS OR FAIL YOUR INSPECTION! Dropped Ceilings and Soffits beneath fire rated assemblies 2021 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. 1. Dropped Ceilings & Soffits: If dropped 1 ¾ inches or less, do one of the following: -Fill spaces with Class A material. -Fill spaces with inorganic or non-combustible material. -Fire block 8 feet in all directions. 2. Dropped Ceilings & Soffits: If dropped greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 3. Dropped Ceilings & Soffits below Heavy Timber T&G ceilings, do all of the following: -One layer 5/8” type X gypsum board directly attached with minimum level one finish. -Drop ceiling according to item 1 or 2 above as applicable. (City Policy) Dwelling Separation Required - 2021 IBC -708 Fire Partitions, 711 Horizontal Assemblies: Walls and floor/ceilings separating dwelling units shall have a fire-resistance rating of at least 1 hour. Walls shall extend from the top of the floor assembly below to the underside of the floor or roof slab or deck above or to the fire-resistance-rated floor/ceiling assembly above. -714: Penetrations must be protected by a through-penetration firestop system. Recessed fixtures shall not reduce the required fire resistance by use of a listed fixture, a listed firehood, or a drywall assembly meeting the required fire resistance. Exhaust fans require ceiling radiation damper. -1207 Sound Transmission: Separating walls and floor/ceilings shall have an STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50. FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2) Existing Fireplaces and Woodstoves: -If you propose to alter the firebox of a fireplace or move a fireplace, it shall be removed or replaced with a gas direct vent or electric appliance. -Conversion to or replacement with gas log is prohibited. -New or replacement gas fireplaces are subject to REMP. -If you propose to move or alter a woodstove, it shall be removed or replaced with a department certified woodstove. IF FRAMING CAVITIES ARE EXPOSED: QUALITY INSULATION REQUIRED If finish materials are removed to expose framing cavities in the thermal envelope, those cavities must be filled with insulation installed to Grade I quality standard (ICC/RESNET 301). Ordinance 1, 2023 Batts/loose fill: Insulation shall be closely fitted wiring, pipes, etc. and avoid substantial gaps, voids or compression. No more than 2% of the total insulated area shall be compressed or contain gaps or voids in the insulation. These areas shall not be compressed more than 3/4 inch. IF YOU EXCEED YOUR APPROVED SCOPE, YOU COULD TRIGGER ADDITIONAL REQUIREMENTS If basement walls in the thermal envelope are altered (removal of finish for example), you must provide the following basement wall minimum insulation unless you can document that it is already present: Residential: R-13 cavity or R-10 continuous Commercial: R-19 cavity or R-20 continuous Ordinance 1, 2023 2021 IBC Code References L 100% of lamps in permanently installed lights must be high efficacy, Ordinance 1, 2023. AS Access and service space for maintenance required, 2021 IMC 306 CO Carbon monoxide detector required per Aspen Municipal Code 8.15 DE Clothes dryer exhaust, 2021 IMC 504. Makeup air required if over 200 CFM SE Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, Ordinance 1, 2023 DV Direct vent sealed combustion required, Ordinance 1, 2023 EP Electric panel happy space: 30in x 36in x 78in, not in storage, NEC 110.26 EE Emergency escape and rescue opening required 2021 IBC 1031 ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2021 IMC 501.3.1 GR Guards, 42in min high, 4in max opening. Guards within dwelling unit 36in min high 2021 IBC 1015 HR Handrails 34in-38in high, 2021 IBC 1014 IT Intake openings 10ft from lot line & contaminant sources (vents, streets), 2021 IMC 401.4 MA Make up air required if hood exhausts greater than 400 CFM, 2021 IMC 505.4 V Mechanical ventilation required, Ordinance 1, 2023 F New or replacement fenestration in existing residential buildings shall not exceed 0.28 U-factor, NFRC label required, Ordinance 1, 2023 SG Safety glazing required, 2021 IBC 2406 SA Smoke alarm per NFPA 72 required, 2021 IBC 907.2.11 WFP Window fall protection- operable window less than 24in AFF and greater than 72in above exterior grade: use opening control device listed to ASTM F2090, 2021 IBC 1015.8 09/11/2023 jimp May 17, 2023 Joel Hocknell Aspen Owner LLC 315 E Dean St Aspen, CO 81611 joelhocknell@gmail.com RE: St Regis Spa Remodel 315 E Dean Street Aspen, Colorado 81611 ESD Project #: 23.068C Joel, As requested, we have been engaged to review the potential structural impact of the proposed remodel at the location noted above. We have received the Spa Demolition Plan D2.1 by Rowland Broughton, dated March 7, 2023. The current proposed scope of work includes modifications to interior walls. Once demolition can begin, the wall and ceiling finishes in these areas, shall be at least partially removed in order to verify the potential effects to the existing structure. We shall be contacted to visually observe the conditions and will then work to define the structural impact of the proposed. This shall be done prior to proceeding with the removal or modification of any framing members, while also allowing sufficient time for the scope of structural engineering to be defined and completed. Please note, no interior partition walls nor ceiling framing shall be removed or modified prior to our observation. Please note that verifications and subsequent recommendations may have a significant impact on the project direction and schedule. Should you have any further questions regarding this matter, please feel free to contact our office. We look forward to working with you through the completion of your remodel. Sincerely, Evolve Structural Design LLC Reviewed By: Steve Edmiston, P.E., S.E. Principal Chris Bridges, E.I. Project Engineer 05/17/2023 06/08/2023 07/20/2023 jimp Page 1 of 2 St. Regis Aspen Spa Remodel Project: 22209.00 – RAKxa Aspen Spa Subject: Fire Protection Letter Date: 19 April 2023 To whom this may concern, This letter is to state that there will be no damage to the existing fire rated assemblies as part of the Interior remodel for St Regis Spa. Property: St. Regis Hotel Area of Remodel: Lower Level Spa Construction Type: 1A The proposed spa remodel will include minor demolition on non-bearing interior partitions and new finishes throughout including the replacement of existing decorative lighting in ceiling. Per IBC Table 601,a Type 1A construction requires no fire rating for nonbearing interior partitions but does require floor assemblies to be 2 hour fire rated. The existing floor/ceiling assembly as seen in previous remodel construction document plan sets, and as shown below, shows the assembly as a 2 Hour fire rated post tension concrete slab. Existing Floor/Ceiling Assembly Detail: 06/08/2023 07/25/2023 jimp Page 2 of 2 Reference Table 601: The interior remodel of the Spa is proposing replacement of finishes and decorative light fixtures, in their current location. Both of these will affect the finish layer of the floor/ ceiling assembly but not penetrate the existing concrete assembly. Please reach out with any questions. Sincerely, Corrie Kowalinski Corrie.kowalinski@rowlandbroughton.com (970)429-8704 Ext 207 06/08/2023 07/25/2023 jimp FIRE SPRINKLERS REQUIRED The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK COMcheck Software Version COMcheckWeb Interior Lighting Compliance Certificate Project Title: 2021 IECC Project Type:Alteration Construction Site: 315 E Dean St Aspen, Colorado 81611 Owner/Agent: Stephane De Baets Elevated Returns 594 Broadway, suite 1106 New York, New York 11012 stephane@elevatedreturns.com Designer/Contractor: Corrie Kowalinski Rowland+Broughton 1830 Blake Street Denver, Colorado 80202 303-308-1373 corrie.kowalinski@rowlandbroughto n.com Project Information Energy Code: RAKxa Wellness Spa At St. Regis Aspen Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 1-Spa Reception #135 (Hotel:Hotel Lobby)670 0.51 342 2-Retail #134 (Retail:Sales Area)310 1.05 326 3-Shower Vestibule #112 (Common Space Types:Restrooms)58 0.63 37 4-Men's Locker Room #138 (Common Space Types:Locker Room)296 0.52 154 5-Men's Hot Tub #109 (Gymnasium/Fitness Center:Playing Area)386 0.85 328 6-Pool Cave #116 (Gymnasium/Fitness Center:Playing Area)428 0.85 364 7-Women's Hot Tub #118 (Gymnasium/Fitness Center:Playing Area)386 0.85 328 8-Women's Restroom (Common Space Types:Restrooms)242 0.63 152 9-Women's Locker Room (Common Space Types:Locker Room)257 0.52 134 10-Employee #131 (Common Space Types:Laundry/Washing Area)52 0.53 28 11-Men's Restroom #139 (Common Space Types:Restrooms)113 0.63 71 12-Tesla Forming Treatment Room #137 (Healthcare Facility:Exam/Treatment) 124 1.40 174 13-Treatment Room #142 (Healthcare Facility:Exam/Treatment)124 1.40 174 14-Treatment Room #143 (Healthcare Facility:Exam/Treatment)126 1.40 176 15-Treatment Room #145 (Healthcare Facility:Exam/Treatment)126 1.40 176 16-Treatment Room #147 (Healthcare Facility:Exam/Treatment)135 1.40 189 17-Hall #146 (Healthcare Facility:Corridor/Transition >=8 ft wide)278 0.71 197 18-Hall #166 (Healthcare Facility:Corridor/Transition >=8 ft wide)403 0.71 286 19-Lounge #156 (Common Space Types:General Seating Area)998 0.23 230 20-Treatment Room #158 (Healthcare Facility:Exam/Treatment)166 1.40 232 21-Treatment Room #160 (Healthcare Facility:Exam/Treatment)149 1.40 209 22-Treatment Room #161 (Healthcare Facility:Exam/Treatment)142 1.40 199 23-Treatment Room #162 (Healthcare Facility:Exam/Treatment)259 1.40 363 24-Treatment Room #164 (Healthcare Facility:Exam/Treatment)125 1.40 175 25-Treatment Room #165 (Healthcare Facility:Exam/Treatment)142 1.40 199 26-Treatment Room#168 (Healthcare Facility:Exam/Treatment)122 1.40 171 27-Treatment Room #169 (Healthcare Facility:Exam/Treatment)143 1.40 200 28-Treatment Room #170 (Healthcare Facility:Exam/Treatment)137 1.40 192 29-Treatment Room #171 (Healthcare Facility:Exam/Treatment)194 1.40 272 30-Treatment Room #173 (Healthcare Facility:Exam/Treatment)112 1.40 157 Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 112 ofPage06/08/2023 07/25/2023 jimp A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 31-Cryo Therapy Treatment Room #136 (Healthcare Facility:Exam/Treatment) 138 1.40 193 32-Employee #133 (Common Space Types:Office - Open Plan)87 0.61 53 33-Shower Vestibule #125 (Common Space Types:Restrooms)36 0.63 23 6501Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture Spa Reception #135 (Hotel: Hotel Lobby, 670 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 11 20 220 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 74 3 222 LED: P-01: New Pendant Light: LED Other Fixture Unit 60W:7 1 60 60 LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 1 4 4 Retail #134 (Retail: Sales Area, 310 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 25 3 75 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 LED: P-02: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60 LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 3 4 14 LED: UC-02: New Vertical Recessed Light Cha: LED Undercabinet Unit 12W:1 10 12 120 Shower Vestibule #112 (Common Space Types: Restrooms, 58 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4 Men's Locker Room #138 (Common Space Types: Locker Room, 296 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 8 20 160 LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17 LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 6 5 30 Men's Hot Tub #109 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36 LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13 LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17 Pool Cave #116 (Gymnasium/Fitness Center: Playing Area, 428 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: UC-03: New Soffit Perimeter Light: LED Linear 15W:1 64 3 192 Women's Hot Tub #118 (Gymnasium/Fitness Center: Playing Area, 386 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 12 3 36 LED: EX-05: Existing Recessed Step Light: LED Undercabinet Unit 4W:1 7 2 13 LED: F-01: New Flush Mount: LED Other Fixture Unit 60W:1 1 17 17 Women's Restroom (Common Space Types: Restrooms, 242 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 9 20 180 LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9 LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10 Women's Locker Room (Common Space Types: Locker Room, 257 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 LED: P-03: New Pendant Light: LED Other Fixture Unit 25W:1 1 17 17 Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 113 ofPage06/08/2023 07/25/2023 jimp E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 4 5 20 Employee #131 (Common Space Types: Laundry/Washing Area, 52 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 2 20 40 LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 1 4 4 Men's Restroom #139 (Common Space Types: Restrooms, 113 sq.ft.) LED: F-03: New Flush Mount Fixture: LED Other Fixture Unit 6.5W:1 2 4 9 LED: S-03: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 5 10 Tesla Forming Treatment Room #137 (Healthcare Facility: Exam/Treatment, 124 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 7 3 21 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 9 15 135 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 Track Lighting: EX-04: Existing Track Light: Wattage based on 8 feet of track 0 0 64 64 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 2 5 10 Treatment Room #142 (Healthcare Facility: Exam/Treatment, 124 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #143 (Healthcare Facility: Exam/Treatment, 126 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #145 (Healthcare Facility: Exam/Treatment, 126 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 4 3 12 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #147 (Healthcare Facility: Exam/Treatment, 135 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 5 3 15 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Hall #146 (Healthcare Facility: Corridor/Transition >=8 ft wide, 278 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 6 20 120 LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 1 26 26 Hall #166 (Healthcare Facility: Corridor/Transition >=8 ft wide, 403 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 7 20 140 LED: F-02: New Flush Mount Fixture: LED Other Fixture Unit 28W:1 3 26 78 Lounge #156 (Common Space Types: General Seating Area, 998 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 21 20 420 LED: EX-03: Existing Soffit Perimeter Light: LED Linear 15W:1 28 15 420 LED: S-01: New Wall Sconce: LED Other Fixture Unit 6.5W:1 2 4 9 LED: P-04: New Pendant Light: LED Other Fixture Unit 60W:4 1 60 60 LED: F-04: New Decorative Light: LED Other Fixture Unit 25W:1 1 17 17 Treatment Room #158 (Healthcare Facility: Exam/Treatment, 166 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20 LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #160 (Healthcare Facility: Exam/Treatment, 149 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #161 (Healthcare Facility: Exam/Treatment, 142 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Treatment Room #162 (Healthcare Facility: Exam/Treatment, 259 sq.ft.) LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 3 5 15 Treatment Room #164 (Healthcare Facility: Exam/Treatment, 125 sq.ft.) LED: EX-01: Existing Recessed Can Light: LED Other Fixture Unit 25W:1 1 20 20 LED: EX-02: Existing Under Cabinet Dimmable: LED Undercabinet Unit 4W:1 6 3 18 LED: S-02: New Treatment Room Wal Sconce: LED Other Fixture Unit 25W:1 1 5 5 Project Title: Data filename: RAKxa Wellness Spa At St. Regis Aspen 05/01/23Report date: 114 ofPage06/08/2023 07/25/2023 jimp 06/08/2023 07/25/2023 jimp