Loading...
HomeMy WebLinkAboutFile Documents.621 W Francis St.0008-2021-BRES (38)These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 0008,0009,0010-2021-BRES COOK ROBERT C & MARSHA N 621 W FRANCIS STREET A&B 273512426011, 273512426012 06/07/2021 External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ 95 sq ft 8/27/21 dam 0010-2021-BRES 95 % SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. FIRE SPRINKLERS REQUIRED SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 8/12/21 MCG/DAM 49 sq.ft. exempt spa These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SPECIAL INSPECTION AND TESTING AGREEMENT This form is required for projects needing special inspection and/or testing per Chapter 17 of the International Building Code (IBC). Project Address: __________________________________ Permit Number: ______________________ BEFORE A PERMIT CAN BE ISSUED: The owner, or the design professional in responsible charge, acting as the owner’s agent, shall complete two copies of this agreement and the attached Special-inspection and Testing Schedule, including the required acknowledgments. A pre-construction conference with the parties involved may be required to review the special-inspection requirements and procedures. APPROVAL OF SPECIAL INSPECTORS: Special inspectors may have no financial interest in the projects for which they provide special inspections. Special inspectors shall be approved by the building department prior to performing any duties. Special inspectors shall submit their qualifications and are subject to personal interviews for pre-qualification. Special inspectors shall display approved identification, as stipulated by the building official, when performing the function of special inspector. Special inspection and testing shall meet the minimum requirements of the International Building Code Section 1704. The following conditions are also applicable: A. Special Inspector Responsibilities: 1. Signify presence at job site. Special inspectors should notify contractor personnel of their presence and responsibilities at the job site. If required by the building official, they shall sign in on the appropriate form posted with the building permit. 2. Observe assigned work. The special inspector shall observe assigned work for conformance with the building department approved (stamped) design drawings, specifications, and applicable workmanship provisions of the International Building Code. Architect\engineer-reviewed shop drawings may be used only as an aid to inspection. For continuous special-inspection, the special inspector shall be on site at all times observing the work requiring special inspection. Periodic inspections, if any, must have prior approval based on a separate written plan reviewed and approved by the building department and the engineer or architect of record. 3. Report nonconforming items. The special inspector shall bring nonconforming items to the immediate attention of the contractor and note all such items in the daily report. If any item is not resolved in a timely manner or is about to be incorporated in the work, the special inspector shall immediately notify the building department by telephone or in person, notify the engineer or architect, and post a discrepancy notice. 4. Provide timely reports. The special inspector shall complete written inspection reports for each inspection visit and provide the reports on a timely basis determined by the building official. The special inspector or inspection agency shall furnish these reports directly to the building official, engineer or architect of record, and others as designated. [IBC Sec. 1704.1.2] These reports should be organized on a daily format and may be submitted weekly at the option of the building official. These reports should include: a. Description of daily inspections and tests made with applicable locations, b. Listing of nonconforming items, c. Report on how nonconforming items were resolved or unresolved as applicable, d. Itemized changes authorized by the architect, engineer, and building official if not included in nonconforming items 5. Provide Final Inspection Report. The special inspector shall submit a written final report documenting required special inspections and correction of any discrepancies noted in the inspections prior to the final building inspection. 621 W Francis st, Aspen 01/21/2021 B. Owner Responsibilities: 1. The project owner, the design professional in responsible charge, or an agent of the owner is responsible for employing special-inspection services. The special inspector/agency shall not be in the employ of the contractor, subcontractor or material supplier. [IBC Sec 1704.1] In case of an owner/contractor, the special inspector\agency shall be employed as specified by the building official. C. Design Professional in Responsible Charge Responsibilities: Design Professional in Responsible Charge definition: An individual who is registered or licensed to practice their respective design profession as defined by the statutory requirements of the professional registration laws of the state or jurisdiction in which the project is to be constructed; who is engaged by the owner to review and coordinate certain aspects of the project, as determined by the building official, for compatibility with the design of the building or structure. 1. Prepare statement of special inspections. The registered design professional in responsible charge shall prepare a statement of special inspections in accordance with IBC Section 1705 for submittal by the applicant. The statement of special inspections shall identify the following: a. The materials, systems, components and work required to have special inspection or testing by the building official or by the registered design professional responsible for each portion of the work. b. The type and extent of each special inspection. c. The type and extent of each test. d. For each type of special inspection, identification as to whether it will be continuous special inspection or periodic special inspection. D. Contractor Responsibilities: 1. Notify the special inspector. The contractor is responsible for notifying the special inspector or agency regarding individual inspections for items listed on the attached schedule and as noted on the building department approved plans. Adequate notice shall be provided so the special inspector has time to become familiar with the project. 2. Provide access to approved plans. The contractor is responsible for providing the special inspector access to approved plans. 3. Retain special inspection records. Upon request, the contractor is also responsible for retaining, at the job site, all special inspection records completed by the special inspector. E. Inspection of Fabricators: 1. Fabrication of structural assemblies and members. Where fabrication of structural load-bearing members and assemblies is being performed on the premises of a fabricator’s shop, IBC Section 1704.2 shall require special inspection of the fabricated items. 2. Fabrication and implementation procedures. The special inspector shall verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control of the workmanship and the fabricator’s ability to conform to approved construction documents and reference standards. The special inspector shall review the procedures for completeness and adequacy relative to code requirements for fabricator’s scope of work. F. Approved Fabricator Responsibilities: 1. Fabrication exempt inspections. Special inspections are not required where work is done on the premise of a fabricator registered and approved to perform such work without special inspection. If work is done on site that requires special inspection, special inspection will be required. 2. Approval of fabricator. Approval shall be based upon review of the fabricator’s written procedural and quality control manuals and periodic auditing of fabrication practices by an approved special inspection agency. 3. Completion of fabrication. Upon completion of fabrication, the approved fabricator shall submit certificate of compliance to the building official stating that the work was performed in accordance with the approved construction documents. 01/21/2021 aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com web: www.aec-vail.com April 30, 2021 Will Otte Rowland + Broughton 1830 Blake St. Denver, CO 80202 Re: Shuford Residence Garage Will, This document is intended to show compliance of the new construction garage located at 621 W. Francis St. in Aspen, CO with the 2015 International Energy Conservation Code (2015 IECC). We propose to use a prescriptive approach per sections R402.1-R402.3 and R403.2.1 of the 2015 IECC. The project is a new garage built on an existing foundation with a total floor area of 803 sf. For heat load calculations, please refer to the following pages of this document. The heat load calculations are performed using the Carrier Hourly Analysis Program and provides a more detailed and accurate load than Manual J. A dewpoint calculation is not included in these permit documents, as the roof assembly meets the requirements of section R806.5 of the 2015 IRC. Building Envelope The following table lists the mandatory minimum insulation and fenestration requirements for the project in climate zone (7). All new assemblies will meet the following requirements. Fenestration U-factor Skylight U-factor Ceiling R-value Wood frame wall U-value Floor R-value Basement wall R-value Slab R-value Code Minimums 0.28 (1) 0.55 49 0.045 38 (2) 15/19 (3) 10 (4) Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7) 2) Or insulation sufficient to fill the framing cavity, R-19 minimum 3) R-15 continuous insulation on the interior or exterior or R-19 cavity insulation on the interior of the wall. Can be satisfied with R-13 cavity plus R-5 continuous. 4) Existing slab to remain Sincerely, Mark Sorensen 05/09/2021 8/12/21 MCG/DAM aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEED TTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com web: www.aec-vail.com April 30, 2021 Will Otte Rowland + Broughton 1830 Blake St. Denver, CO 80202 Re: Shuford Residence Will, This document is intended to show compliance of the remodel construction residence located at 621 W. Francis St. in Aspen, CO with the 2015 International Energy Conservation Code (2015 IECC). We propose to follow the prescriptive requirements for alterations approach per sections R503.1-R503.2 of the 2015 IECC. The project is an existing residence with a total floor area of 3,478 sf. For heat load calculations, please refer to the following pages of this document. The heat load calculations are performed using the Carrier Hourly Analysis Program and provides a more detailed and accurate load than Manual J. A dewpoint calculation is not included in these permit documents, as the roof assembly meets the requirements of section R806.5 of the 2015 IRC. Building Envelope The following table lists the mandatory minimum insulation and fenestration requirements for the project in climate zone (7). All new or altered assemblies will meet the following requirements. Fenestration U-factor Skylight U-factor Ceiling R-value Wood frame wall R-value Floor R-value Basement wall R-value Slab R- value Code Minimums 0.28 (1) 0.55 (2) (3) 38 (4) 15/19 10, 4 ft Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7) 2) R-49 cavity insulation in new or insulation sufficient to fill the existing framing cavity 3) U-0.045 in new or insulation sufficient to fill the existing framing cavity 4) Or insulation sufficient to fill the framing cavity, R-19 minimum Sincerely, Mark Sorensen 05/09/2021 8/12/21 MCG/DAM G. Building Department Responsibilities: 1. Approve special-inspection program. The building department shall approve all special inspectors and special-inspection requirements. 2. Enforce special inspection. Work requiring special inspection and the building inspector shall monitor the performance of special inspectors. His/Her approval, in addition to that of the special inspector, must be obtained prior to placement of concrete, covering of structural steel, or other similar materials. 3. Review inspection reports. The building official should review special-inspection progress and final reports. 4. Perform final inspection. The building official should perform the final inspection and approval for a project [IBC Sec. 109.3.1] after the final special-inspection report has been reviewed and approved. Project Address: 621 W Francis St, Aspen Permit Number: ACKNOWLEDGMENTS I have readLand agree to compW with the conditions of this agreement. Special Inspectio( Agency*** SignatureOwner* rowland+broughton Design Professional in Signature Responsible Charge*/** HD Construction Contractor Email Signature Printed Name Date Will Qtte Printed Name Hugh Marsh Printed Name Date Email 12/16/20 will@rowlandbroughton.com Date Email 12/16/20 hmarsh@hdaspen.com Email Approved Fabricator*** Inspected Fabricator*** City of Aspen Building Department: Signature Printed Name Date Email *Either the Owner or the Design Professional in Responsible Charge must sign. "The Design Professional in Responsible Charge is not required to sign if they perform the duties as described in item C above. *** Either the Approved Fabricator or Inspected Fabricator must sign. If all work is performed in the shop of an Approved Fabricator, the Special Inspection Agency signature is not required (no field work). •?0.5! 0008-2021-BRES 0009-2021-BRES 0010-2021-BRES Justin Hahn 9/27/21 justin.hahn@cityofaspen.com 8/12/21 MCG/DAM COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT CONTACT SHEET CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP OWNER ___________________________________ _____________________ ________________________Name Phone E-mail FOR PLAN REVIEW QUESTIONS ___________________________________ _____________________ ________________________Name Phone E-mail FOR INSPECTION QUESTIONS ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP OWNER’S AUTHORIZED AGENT ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP APPLICATION BEST CONTACT ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP ARCHITECT OR DESIGNER OF RECORD ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP CIVIL ENGINEER OF RECORD ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP STRUCTUAL ENGINEER OF RECORD I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. It is my responsibility to review the approved plans and any comments that are contained thereon and see that the structure and/or project is built in compliance with all applicable codes. ________________________________________________________ _____________________ContractorSignature Date INSPECTIONS: The General Contractor must schedule inspections online. Please visit www.aspenpitkin.com/Departments/Community-Development-Forms/ to do so. ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP GENERAL CONTRACTOR Check if you are a tested owner builder (single-family homes only). You must take a test and complete the owner/building affidavit. (CITY USE ONLY) Owner builder approved by:________________________Date:______________________ Affidavit on file ADDRESS: ____________________________PERMIT NUMBER: _______________________________ August 2017 621 W. Francis St A & B 0008,0009,0010-2021-BRES Will Otte will@rowlandbroughton.com James and Josie Shuford 621 W. Francis St Aspen CO 81611 jshuford@shurtape.com Will Otte (rowland+broughton)970.379.6962 500 W. Main St.Aspen CO 81611 will@rowlandbroughton.com 970.544.9006Sarah Broughton 500 W. Main St Aspen CO 81611 sarah@rowlandbroughton.com 970.945.8676Roger Neal 1517 Blake Ave, STE 101 Glenwood Springs CO 81601 rneal@hceng.com Dustin Wheatley 319.721.9334 1040 Main Street Carbondale CO 81623 dustin@evolvestruct.com 970 3794009Hugh Marsh, HD Construction 907 3794009 PO Box 4782 aspen co 81611 hmarsh@hdaspen.com 12/23/20 01/21/2021