Loading...
HomeMy WebLinkAboutFile Documents.975 King St.0043-2020-BRES (25) aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24,Suite 214,Eagle-Vail, CO 81620 Post Office Box 8489,Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com:www.aec-vail.com Wall Insulation Calc – 975 King Street Below is a U-Value calculation for an exterior wall for 975 King Street. The calculation is based off of the U-Factor Alternative (R402.1.4). Component Cavity Studs R-Value R-Value Outside air Film 0.17 0.17 Wood Siding 0.34 0.34 Plywood 1/2" 0.63 0.63 Continuous Insulation - - Insulation 36 - Wood Studs - 6.875 5/8" Gyp. Board 0.56 0.56 Inside Air Film 0.68 0.68 R-Value Total 38.38 9.255 U-Factor Total 0.026055 0.10805 Framing Factor 0.77 0.23 U-value with Framing Factor 0.020063 0.024851 Total U-Value (Cavity + Stud U-value) 0.044913964 With a cavity insulation of R-36 and no continuous insulation, we are below the required .045 u- value which verifies compliance. Date: 01/11/2021 Client: DJArchitects Project: 975 King Street Prepared by: Dan Findley Project No.: 19073