HomeMy WebLinkAboutLand Use Case.630 E Hyman Ave.0005.2010.AHPCA (' 2
F E D A5.1 B A6.13 A
59'-5"
15'-2" 10'-3" 8'-0" 10'-3" 15'-9"
BUILDING SECTION - PROPOSED
SCALE: 1/4" = 1'-0"
I
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A5-1.dwg
SHEET TITLE
PROPOSED
BUILDING
SECTION B
SCALE: 1/4" = T-0"
A5.2
COPYRIGHT 2010 ROWLAND-BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
�I
0
'i
s 7
n
AB.2 \ ' /
70
A4.4 SCALE: 1/4" = 1'-0" I I I I DASHED
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A4-1.dwg
SHEET TITLE
PROPOSED
WEST ELEVATION
SCALE: 1/4" = 1'-0"
A4m4
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLANO+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTONARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
94'-3"
7'-6"
TO FACE OF
TO FACE OF
10'-3"
8'-0"
10'-3"
15'-4" SECOND LEVEL BEAM
SECOND LEVEL BEA 20'-0"
17-11
A4.4 SCALE: 1/4" = 1'-0" I I I I DASHED
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A4-1.dwg
SHEET TITLE
PROPOSED
WEST ELEVATION
SCALE: 1/4" = 1'-0"
A4m4
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLANO+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTONARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
OF
nE
D a ncA5.1
NORTH ELEVATION - PROPOSED
SCALE: 1/4" = 1
ALLEY
......................................... ..........................
........................................ ..........................
......................................... ..........................
........................................ ......................
......................................... _ ..........................
....................................... ..............................
...................................._ .........................
..................................... .....................
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
59'-5"
970.544.9006 v
303.308.1373 v
15'-2"
10'-3"
8'-0"
10'-3"
NORTH ELEVATION - PROPOSED
SCALE: 1/4" = 1
ALLEY
......................................... ..........................
........................................ ..........................
......................................... ..........................
........................................ ......................
......................................... _ ..........................
....................................... ..............................
...................................._ .........................
..................................... .....................
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A4-1. dwg
SHEET TITLE
PROPOSED
NORTH ELEVATION
SCALE: 1/4" = 1'-0"
A4.3
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND*BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND*BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
L_ _j L- -J L- -J L- -J L_ -J L_J L
r7� EAST ELEVATION - PROPOSED
A4.2 j SCALE: 1T4" = V-0"
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRAN DALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A4-1.dwg
SHEET TITLE
PROPOSED
EAST ELEVATION
SCALE: 1/4" = V-0"
A4.2
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+SROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
.............
s'
..... .... ..
.....
. .
.. . -..? =.... . .. .
rowland
+ broughton
architecture
and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRAN DALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A4-1.dwg
SHEET TITLE
PROPOSED
EAST ELEVATION
SCALE: 1/4" = V-0"
A4.2
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+SROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
ROOF TOP MECHANICAL
EQUIPMENT-T.B.D.
CYLINDRICAL METAL
CLAD ELEVATOR
OVER RUN BEYOND
36' HEIGHT LIMIT
nA nB D nE
nc n
CONCRETE PANELS WITH
VERTICAL CONTROL
JOINTS OR REVEALS
METAL FASCIA
TAMARAWOOD
BUILDING
N
I �
— — — — — — — — — — — — — — —
SOUTH ELEVATION - PROPOSED
SCALE: 1/4" = 1'-0"
rZ—�� ----- �Z—T--------- —�—��
_J L_ - - _l
METAL CHIMNEY
METAL FASCIA
ALUMINUM CLAD WINDOWS
AND DOORS
METAL PANELS WITH
VERTICAL CONTROL
JOINTS OR REVEALS
42" GLASS
GUARDRAIL
EXISTING STAINED
SIDING
EXISTING C.M.U. /
CONCRETE COLUMN
TO REMAIN
EXISTING SITE WALL
TO REMAIN
SPRING
STREET
T.O. ROOF dk
132'-6 1/4"
120'-7"
T.O. SLAB
90'-5"
......................................... ......I...................
............................ ...................
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
59'-5"
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
15'-9"
10'-3"
8'-0"
10'-3"
15'-2"
CONCRETE PANELS WITH
VERTICAL CONTROL
JOINTS OR REVEALS
METAL FASCIA
TAMARAWOOD
BUILDING
N
I �
— — — — — — — — — — — — — — —
SOUTH ELEVATION - PROPOSED
SCALE: 1/4" = 1'-0"
rZ—�� ----- �Z—T--------- —�—��
_J L_ - - _l
METAL CHIMNEY
METAL FASCIA
ALUMINUM CLAD WINDOWS
AND DOORS
METAL PANELS WITH
VERTICAL CONTROL
JOINTS OR REVEALS
42" GLASS
GUARDRAIL
EXISTING STAINED
SIDING
EXISTING C.M.U. /
CONCRETE COLUMN
TO REMAIN
EXISTING SITE WALL
TO REMAIN
SPRING
STREET
T.O. ROOF dk
132'-6 1/4"
120'-7"
T.O. SLAB
90'-5"
......................................... ......I...................
............................ ...................
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920 A4-1.dwg
SHEET TITLE
PROPOSED
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
A401
COPYRIGHT 2010 ROWLAND-BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
0
CP
Lo
T
A
ih
1 0
A4.1.1 T
E
F
M
0
T
E
7'-6"
15'-4"
2
10'-3"
1
A4.4
3
MIA
11I
94'-3"
10'-3"
G'1
17'-11"
1.9
20'-0"
7
5'-0"
9
PLAN NOTES
• GRID LINES ARE TO
BEAMS AND FACE 0
• DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF
STUD OR CONCRETE WALLS.
• PLAN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DIMENSIONAL DISCREPANCIES. DO NOT SCALE DRAWINGS.
• EQDESIGNATED AT DOORS AND WINDOWS DENOTES MEANS OF
EGRESS PER I.R.C. R310.
• BUILDING ELEVATION 100'-0" = SITE ELEVATION 7923.84'
• FIRE SPRINKLES ARE REQUIRED THROUGHOUT BUILDING.
• ALL BATHROOM AND LAUNDRY AREAS TO BE EQUIPPED WITH
MECH. VENTILATION.
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
APPLICABLE LOCATIONS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
LOCATIONS.
• ALL ROOF AND DECKS TO SLOPE A MIN. a'/FT TO DRAINS.
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
3
SPRING STREET
BELOW
1 ROOF LEVEL PLAN
A2.4 SCALE: 1/4" = V-0"
1 21 Lei
L4 PJ -A I L#74* -),j
8'-0" 10'-3" 17'-11" 20'-0"
94'-3" 11
M
5
0
0
e
-.,.,.,.
......... .
...: .
:.......
f . ... -Y"
rowland + broughton
architecture and urban design
117 s. monarch st. 3377 blake st, 106
aspen, co 81611 denver, co 80205
970.544.9006 v 303.308.1373 v
970.544.3473 f 303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRAN DALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A2-4.dwg
SHEET TITLE
PROPOSED
ROOF PLAN
SCALE: 1/4" = 1'-0"
A2.4
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO,
B
EXISTING
PARAPET WALL
BELOW
M
1 '
a
L5
F
C?
0
1
7'-6"
1
2 Aa.a 3
10'-3"
8'-0"
94'-3"
10'-3"
TAMARAWOOD
5
BUILDING
3 CYLINDRICAL METAL CLADW3 PARAPET WALL TO COMPLY WITH
A7 3 ELEVATOR OVER RUN ABOVE Ap 2003 IBC SECTION 704.11.5.2
D
20'-0"
1
A6.2
7
U
PLAN NOTES
• GRID LINES ARE TO CENTER LINE OF EXISTING COLUMNS AND
BEAMS AND FACE OF CONCRETE AT FOUNDATION.
• DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF
STUD OR CONCRETE WALLS.
• PLAN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DIMENSIONAL DISCREPANCIES. DO NOT SCALE DRAWINGS.
• EIDESIGNATED AT DOORS AND WINDOWS DENOTES MEANS OF
EGRESS PER I.R.C. R310.
• BUILDING ELEVATION 100'-0" = SITE ELEVATION 7923.84'
• FIRE SPRINKLES ARE REQUIRED THROUGHOUT BUILDING.
• ALL BATHROOM AND LAUNDRY AREAS TO BE EQUIPPED WITH
MECH. VENTILATION.
r
• ALL EXTERIOR STAIRS TO BE EQUIPPED WITH ILLUMINATION.
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
APPLICABLE LOCATIONS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
LOCATIONS.
• ALL ROOF AND DECKS TO SLOPE A MIN. a'/FT TO DRAINS.
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
I 3 I I I
I A7.3 I I I I I
CMU/CONC. EXISTING 1
COLUMN BELOW, PARAPET A6.1
TYP.
SPRING STREET
(BELOW) 1 THIRD LEVEL PLAN - PROPOSED
A2.3 SCALE: 1/4" = 1'-0" PLAN TRUE
NORTH NORTH
M mqzz:!!�
k -A km
8'-0" 10'-3" 17'-11 " 20'-0" 5'-0"
94'-3"
0
B
A5.2
5
0
7
2
A6.2
M
0
0
B
3
A7.3
C?
0
/ E
F
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
GUARDRIAL IBC SECTION 1012 W
.7
970.544.3473 f
303.308.1375 f
o
BENCH
W3
A7.1
I
_ r
TILE
1s
4
14
z5
O
24 F.D
DECK
STUDY
312
GUEST
BATH
a
F-
0
�.--
---- ----�—
---- ----�
--�—
— --
2/311
! 311
I
GUEST
w
— — —
CPT ! STN 1/311
z `
63 0ED 2
a I
O
84 SF PA—�'
_
—_ —
of
1 1
7/011
1
O I
UF.D.
1
1
IISTAIR
OOD C tPT
2/310
I
I
1
011
m
ELEVATOR
i
= — — —
BENCH
HANGING
DESK
Q
(
I 1
O I
9 R @
9/ 6" DN w
1
HALL CUBBIES ABOV
— — HP —
TV
I DRESSER
II
1
6"
I 1
w
8T@
1 zo
1
317
y O R.
I 1
w
HA Q AI PER IBC S
C 10 1009.11
Q
�
1 1
— — —
1
!
BENCH
-�
ISI o �I�
W4
--------
_REF/
FRZ.
tU1
A7.1
o
CD
-------------�
n
--I—���-�� .._---
1
1 I
l LOBBY
- —
I I
( uj
NDRY
I 313 �---- ,
`'' I MECH.
FT309308
GUEST
I
0
�-
I
(
II I I II II I II : II !I 11 i) .I II
1 ! I II i)
STONE
II II II II II II ' ! INSETC
F OOR WIT
CO'MAl�ll 302
I
I
Y
z I ACCESS I
GUES
BATH 1 z
BED 1
�I
w
.I II li !!
!! II !! !! !I !! I ! !! 1! I!
: ! II !! !i 11 I! II 11 !1 !i II
`n I L I
Is
vl
/1
! 1 !L I1 !' III !
°
0�L
! II!!LIIIi.11!Illifl11lI�II II':IIII!1111li11ii!I'I'
FLOOR
WID DRAIN STONE
! WOOD
- -
wl
p
w
I
11 11 11 11 11 11 11 li II II . II II II
!I III !! ii 11 11 l! r
WINE
I- _ J
N
11 'ILII
I
I=
WOOD I_ CPT
I I
al
!I ¢
I' !I
li !I�il ! II
!
1
z/3oa
I ! I
!I N
! it
I I w
! I
J
g
1
1/30
I II II II II II II 'I !I !! I! II II L II it
it !'! I! !! !I !!
O
!' !! I. !! it i! 11 li 't w
I1 I! II I!
I ! ! �' II I,
! �! !. I. li it I I o I
1' !I 11 ! !! II �I !! �' I I U
POWDER
° 30730.
®
DRESSER
I
':I
— HANGING
_LTV
DESK —
— — — — —
Q
I
I
!
I
I. II I! n I! it li li I. II
REF. ! U
ih II it !i it !
!I !! i1 i' I! I! j!
I
I
I
1/307
1/317 CLOSET
— —
HP
o
II 11 :I .I
L _-
u it rt` ' u�J L'—'� d � I� LI—
— —
z/3os
O [� P
L LL
1 j
I
n FFA FFFFrinnnF:
I „
nnnnnF ART
- e
is
rlrInnr
- -n P. n-
F rIrn
I
N
>AI I�A i
I
O
m
I a
W
1w
I
NUTE,!
! Ii ! II !! !I
I �I LOCATION & tJUMB,ER o
POWER SHADES /DRAPES
II !I . II ;I II 11
li II it !I I!�' '' 'I li I!
I i! it II II I� "I�§Ai�! SI IT II
OiV,
II II 11 I! !! I. III
it II II !! it II I! i! I
1 I.
! II II II :HALL I! n I! ! II !! I! I
!I il. '! 306! !I li it I! I! !I I! I
n l' I III it ',, , i,
I II II II II .1 III ;I !! ! !I II
I I! 11 '! '! '! II !I II II it I! !! II il. I
I! I! I I1 11 I1 11 11
I !! !I !I !I II I! I! II.
I1 WOODI
II !I 1
I I STONE
'I I~ DN
R @ .1 5"
8 � 10'
F.D.
Q
I
II T.B.D.
i!I !I II I! I
.
I II u
,
7/012
---I
W
I
U U U U U U U U U U U U U U U L
U U U U U U U L —
�U J L U U U U U U U J U
u U ._ U U
U J U
WOOD PANELWAL_L -
U I
MIRROR - -
I a '..! �.
U L L y
---
TILE I
I I
STAIR
DECK I
I I
012
—
! !
REF.
OVEN/ —
CU IES
DRA ERS
MIRROR
DRAWERS
2/3141
Jlg 1
I
I ROOF I
8 @ 8.125"
MICRO
DOORI
ACCESS I
T 1 "
A7.3
I
I
I
MASTER
HATCH I
AN R IL E I C SECTION
1009.11
-
— I 0
I I
MECH. CLOSET _
ACCESS
_
_1
L - - _ -
-
I
I
1
L ---J HANGING
�
---------------I
-----
I
I
TILE
WOOD
L
I
J
z
WOOD
�
WOOD
I I
I Q
I w o 00,1
I
I
I
I
I LIVING
304
I
J
J O Lu 17
°
I
KITCHEN
®
~
w
I
305 1
MASTER �I
1/3oa
I
I
I
I
(
WC WOOD CEILING
MASTER
BATH
BED ° 1
314 W i
zo
I 1
DWI
ABOVE
315
Q
I!
I
u11
WARM�I
DRAWER
I
(I
I
!
L —
J
W1
—
— I —
WOOD SOFFIT
I — f•— —
WOOD CEILING
I 1
— — —TV IN NICHE— —
— — —•, —
1
—
— APP
_
STEAM
O
_
WOO CEILING
1
l
ABOVE
I
ABOVE
_ —
FIREPLACE
PANT
O
0
O
BOVE
I
1 R.D.
-- ---- -1
_
--------�
-- 1- - -
-- - - -
------ _ _-.Q\
BENCH �
E 0
POCKET
I
0---
--------
--- ---
SHADE POCKET
---SHADE
1
2/304 t
-- ---- --
�►
1
1 /305
w
17 }
18 W
W -X �
1/314
.D.
1------
— — — — — — — — — — —
BBQ
— — — — —
WOOD SOFFIT
ABOVE
EAVE ABOVE
I
I
I
A-
7
GUARDRIAL IB SECTION 1012 &1607.7
F.D.
F.D.-----__GUARDRIAL
IBC S CTION 1012
&1607.7
F.D.
co
PLAN NOTES
• GRID LINES ARE TO CENTER LINE OF EXISTING COLUMNS AND
BEAMS AND FACE OF CONCRETE AT FOUNDATION.
• DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF
STUD OR CONCRETE WALLS.
• PLAN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DIMENSIONAL DISCREPANCIES. DO NOT SCALE DRAWINGS.
• EIDESIGNATED AT DOORS AND WINDOWS DENOTES MEANS OF
EGRESS PER I.R.C. R310.
• BUILDING ELEVATION 100'-0" = SITE ELEVATION 7923.84'
• FIRE SPRINKLES ARE REQUIRED THROUGHOUT BUILDING.
• ALL BATHROOM AND LAUNDRY AREAS TO BE EQUIPPED WITH
MECH. VENTILATION.
r
• ALL EXTERIOR STAIRS TO BE EQUIPPED WITH ILLUMINATION.
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
APPLICABLE LOCATIONS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
LOCATIONS.
• ALL ROOF AND DECKS TO SLOPE A MIN. a'/FT TO DRAINS.
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
I 3 I I I
I A7.3 I I I I I
CMU/CONC. EXISTING 1
COLUMN BELOW, PARAPET A6.1
TYP.
SPRING STREET
(BELOW) 1 THIRD LEVEL PLAN - PROPOSED
A2.3 SCALE: 1/4" = 1'-0" PLAN TRUE
NORTH NORTH
M mqzz:!!�
k -A km
8'-0" 10'-3" 17'-11 " 20'-0" 5'-0"
94'-3"
0
B
A5.2
5
0
7
2
A6.2
M
0
0
B
3
A7.3
C?
0
/ E
F
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRAN DALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A2-3.dwg
SHEET TITLE
PROPOSED
THIRD LEVEL
PLAN
SCALE: 1/4" = 1'-0"
A2.3
COPYRIGHT 2010 ROWLAND-BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
0
C
a
L
It
19
M
0
r
EXISTING R(
OPENING T
INFILLED V
OPERABLE R
WINDOb
M
0
PLAN NOTES
E
2
3
6i
u
7
94'-3"
7'-6" 154" 1 10'-3" 1 8'-0" 1 1 10'-3" 1 17'-11" 1 20'-0" 1 _ 5'-0"
• GRID LINES ARE TO CENTER LINE OF EXISTING COLUMNS AND
BEAMS AND FACE OF CONCRETE AT FOUNDATION.
• DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF
STUD OR CONCRETE WALLS.
• PLAN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DIMENSIONAL DISCREPANCIES. DO NOT SCALE DRAWINGS.
•ElDESIGNATED AT DOORS AND WINDOWS DENOTES MEANS OF
EGRESS PER I.R.C. R310.
• BUILDING ELEVATION 100'-0" = SITE ELEVATION 7923.84'
• FIRE SPRINKLES ARE REQUIRED THROUGHOUT BUILDING.
• ALL BATHROOM AND LAUNDRY AREAS TO BE EQUIPPED WITH
MECH. VENTILATION.
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
APPLICABLE LOCATIONS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
LOCATIONS.
• ALL ROOF AND DECKS TO SLOPE A MIN. a'/FT TO DRAINS.
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
K
1 SECOND LEVEL PLAN - PROPOSED
SPRING STREET �.2SCALE: 1/4" = 1'-0"
BELO PLAN TRUE
(' M NORTH NORTH
8'-0" 10'-3" 17'-11 " 20'-0" 5'-0"
94'-3"
rd
5
R
7
0
E•�
......................................... _. _ . . .............I............
..................
......................................... .....I..............__..
..........................
............................_ ..........................
......................._....
rowfand + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
FLAT
SKY LIGHT
E: STRUCT & GLASS
MANUFACTURE
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
APPLICABLE LOCATIONS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
LOCATIONS.
• ALL ROOF AND DECKS TO SLOPE A MIN. a'/FT TO DRAINS.
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
K
1 SECOND LEVEL PLAN - PROPOSED
SPRING STREET �.2SCALE: 1/4" = 1'-0"
BELO PLAN TRUE
(' M NORTH NORTH
8'-0" 10'-3" 17'-11 " 20'-0" 5'-0"
94'-3"
rd
5
R
7
0
E•�
......................................... _. _ . . .............I............
..................
......................................... .....I..............__..
..........................
............................_ ..........................
......................._....
rowfand + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A2-2. dwg
SHEET TITLE
PROPOSED
SECOND LEVEL
PLAN
SCALE: 1/4" = 1'-0"
A2.2
COPYRIGHT 2010 ROWLAND-BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
:j
1 Cl) BENT STEEL
COUNTER T(
EXISTING SI1
WALL TO RE
C
3377 blake st, 106
2/101
94'-3"
970.544.9006 v
303.308.1373 v
7'-6" 164"
10'-3" 8'-0"
1
10'-3"
17'-11 " 20'-0"
z
A4.1
Cn
C�
It
TAMARA WOOD
�
0
o
80
Q
z
A
0 I I
JI I I
Q
A5.1
I
I
FIRE CONTROL (e)
(
D
PANEL LOCATION
M
0
4
in
1
A4.4 3
n4 B
A5.2 n
n n
BUILDING
EGRESS PATH HiIi 1/108 UNIT
1/10 107
4/011105
VESTIBULE
Q. _ ---F 108
z T. O. CONC.
100'-0"
15-< I
w I
I 1!106
I
01
UNIT
106
I
I (e)
T. O. CONC.
100'-0"
(e)
' 9R@ v 1016 UP
' 8T@ 111'
STAIR
011
ELEVATOR
9R@ 6 3/6"
DN
HANDRAIL PER IBC SECTICN 1 09 11
a---------------------------------�
RD RD 2
T. O. CONIC A6.14
100'-0"
W1
2/106
r----- ——�--- A7.1
I ------ ------ -- --71, IL
I I I I
NAM
UNIT
104
OPEN TO BELOW
& ABOVE I oa
I I
I I I THIN COAT CONCRETE WITH
I i i I I i I CONTROL JOINTS OVER
EXISTING SUBFLOOR
WX
I Ax.X W1
C= COURTYARD I A7.2
100 I (e)
—
I I I I
I I I I
I I I I
--- ------ -- — — — — I
L--------1�- - - - - - - -I------� I
UAR RIAL IBC SECTION 1012 1637.
(e)
W1 W1
ORD A7.2 A7.2 RDS
(e)
3377 blake st, 106
2/101
94'-3"
970.544.9006 v
303.308.1373 v
7'-6" 164"
10'-3" 8'-0"
Li
10'-3"
17'-11 " 20'-0"
71,
C�
It
TAMARA WOOD
I
BUILDING
EGRESS PATH HiIi 1/108 UNIT
1/10 107
4/011105
VESTIBULE
Q. _ ---F 108
z T. O. CONC.
100'-0"
15-< I
w I
I 1!106
I
01
UNIT
106
I
I (e)
T. O. CONC.
100'-0"
(e)
' 9R@ v 1016 UP
' 8T@ 111'
STAIR
011
ELEVATOR
9R@ 6 3/6"
DN
HANDRAIL PER IBC SECTICN 1 09 11
a---------------------------------�
RD RD 2
T. O. CONIC A6.14
100'-0"
W1
2/106
r----- ——�--- A7.1
I ------ ------ -- --71, IL
I I I I
NAM
UNIT
104
OPEN TO BELOW
& ABOVE I oa
I I
I I I THIN COAT CONCRETE WITH
I i i I I i I CONTROL JOINTS OVER
EXISTING SUBFLOOR
WX
I Ax.X W1
C= COURTYARD I A7.2
100 I (e)
—
I I I I
I I I I
I I I I
--- ------ -- — — — — I
L--------1�- - - - - - - -I------� I
UAR RIAL IBC SECTION 1012 1637.
(e)
W1 W1
ORD A7.2 A7.2 RDS
(e)
9
AM
CI
(e)
SPRING STREET
10'-3"
94'-3"
61
(e)
17'-11"
A6.2
I I I
F_ — — —
I
I I
I I II
I
I
i F.D.
W2 2
A7.1 —
I I
I
i I
1 II T. O. ASPHALT
3/103 I 98'-3"
UNIT I I
103 II
I F.D. I
_ I
T. O. CONIC
98'-3" 1 I
4 @ 7"
z o DN 3 @ 11„ \\
O
1/104 O
X.
C
(e) — — — O I EXISTING
012 DN 9 R@ 7.1 5" I GARBAGE /
8 T @ 10" I RECYCLING 1
' I HAN R IL E IB S C 10 1 09.11
EXIT I A4.3
I � 4r012 i J o
IQ
Co A
9 @ 7"
UP 8 T @ 117'
z
(e) --- ov ....
ELECTRIC METER
---------- -----
Z5/012 2
O A6.12
U EXIT DISCHARGE
I
T. O. CONC. _
1 100'-0" I o
— I
— I
1/102
UNIT W1
102 LAA7tL1j
(e)
I I
— — — — E
I
I
Iw
(e)>
I I1 m
Iw
Iw
lz
CV
21102 U '
I III II(D 'r
Ix
Iw
W1
A7.1
I I (e) I
I
0 LOW EXHAUST
- F
(e) HIGH SUPPLY DN
I 1 I 1 I
A6.1
1 MAIN LEVEL PLAN - PROPOSED
A2.1 SCALE: 1/4" = 1'-0" PLAN TRUE
NORTH NORTH
20'-0"
iJ
rl
5'-0"
0
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
2/101
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Li
UNIT
C�
I
101
0 I I
JI I I
I
I
FIRE CONTROL (e)
(
PANEL LOCATION
T.B.D.
I
(e) (e)
PLAN NOTES
• GRID LINES ARE TO CENTER LINE OF EXISTING COLUMNS AND
• ALL EXTERIOR STAIRS TO BE EQUIPPED WITH ILLUMINATION.
BEAMS AND FACE OF CONCRETE AT FOUNDATION.
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
• DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
STUD OR CONCRETE WALLS.
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• PLAN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE OVER
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
SCALED DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
APPLICABLE LOCATIONS.
DIMENSIONAL DISCREPANCIES. DO NOT SCALE DRAWINGS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
• E❑DESIGNATED AT DOORS AND WINDOWS DENOTES MEANS OF
LOCATIONS.
EGRESS PER I.R.C. R310.
• ALL ROOF AND DECKS TO SLOPE A MIN. 17FT TO DRAINS.
• BUILDING ELEVATION 100'-0" = SITE ELEVATION 7923.84'
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
• FIRE SPRINKLES ARE REQUIRED THROUGHOUT BUILDING.
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• ALL BATHROOM AND LAUNDRY AREAS TO BE EQUIPPED WITH
MECH. VENTILATION.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
9
AM
CI
(e)
SPRING STREET
10'-3"
94'-3"
61
(e)
17'-11"
A6.2
I I I
F_ — — —
I
I I
I I II
I
I
i F.D.
W2 2
A7.1 —
I I
I
i I
1 II T. O. ASPHALT
3/103 I 98'-3"
UNIT I I
103 II
I F.D. I
_ I
T. O. CONIC
98'-3" 1 I
4 @ 7"
z o DN 3 @ 11„ \\
O
1/104 O
X.
C
(e) — — — O I EXISTING
012 DN 9 R@ 7.1 5" I GARBAGE /
8 T @ 10" I RECYCLING 1
' I HAN R IL E IB S C 10 1 09.11
EXIT I A4.3
I � 4r012 i J o
IQ
Co A
9 @ 7"
UP 8 T @ 117'
z
(e) --- ov ....
ELECTRIC METER
---------- -----
Z5/012 2
O A6.12
U EXIT DISCHARGE
I
T. O. CONC. _
1 100'-0" I o
— I
— I
1/102
UNIT W1
102 LAA7tL1j
(e)
I I
— — — — E
I
I
Iw
(e)>
I I1 m
Iw
Iw
lz
CV
21102 U '
I III II(D 'r
Ix
Iw
W1
A7.1
I I (e) I
I
0 LOW EXHAUST
- F
(e) HIGH SUPPLY DN
I 1 I 1 I
A6.1
1 MAIN LEVEL PLAN - PROPOSED
A2.1 SCALE: 1/4" = 1'-0" PLAN TRUE
NORTH NORTH
20'-0"
iJ
rl
5'-0"
0
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRAN DALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_A2-1.dwg
SHEET TITLE
PROPOSED
MAIN LEVEL
PLAN
SCALE: 1/4" = 1'-0"
A2.1
COPYRIGHT 2010 ROW LAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAYBE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
L€
a�SS
1L S
1
2
1
A4.4
3
El
5
[:1
7
94'-3"
7'-6" 15'-4" 10'-3..
8'-0" 10'-3" ol 17'-11" 20'-0" 5'-0"
• UMU LINtJ HKt I V IiCIV 1 CR LIING Vr Gn10I IIVv vvLvlviiw ruvv
BEAMS AND FACE OF CONCRETE AT FOUNDATION.
• DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF
STUD OR CONCRETE WALLS.
• PLAN DIMENSIONS SHALL ALWAYS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DIMENSIONAL DISCREPANCIES. DO NOT SCALE DRAWINGS.
• EEIDESIGNATED AT DOORS AND WINDOWS DENOTES MEANS OF
EGRESS PER I.R.C. R310.
• BUILDING ELEVATION 100'-0" = SITE ELEVATION 7923.84'
• FIRE SPRINKLES ARE REQUIRED THROUGHOUT BUILDING.
• ALL BATHROOM AND LAUNDRY AREAS TO BE EQUIPPED WITH
MECH. VENTILATION.
• SMOKE AND CO ALARMS TO BE INSTALLED IN ALL SLEEPING
AREAS, OUTSIDE EACH SEPARATE SLEEPING AREA AND ON EACH
ADDITIONAL STORY. ALL ALARMS TO BE INTERCONNECTED.
• CONTRACTOR TO INSTALL PRESSURE TREATED WOOD AT ALL
APPLICABLE LOCATIONS.
• HEAT TAPE TO BE PROVIDED AT ALL ROOF DRAINS AND SCUPPER
LOCATIONS.
• ALL ROOF AND DECKS TO SLOPE A MIN. 17FT TO DRAINS.
• TEMPERED GLASS IS REQUIRED WITHIN 12" OF ALL DOORS, 18"
A.F.F. AND IN ALL STAIRWAYS AND BATHROOM SHOWER
ENCLOSURES.
• REFER TO BASE BUILDING CODE PLANS FOR ALL FIRE
SEPARATIONS.
M
FAM
M
SPRING STREET 1 BASEMENT LEVEL PLAN - PROPOSED
(ABOVE)
SCALE: 1/4" = 1'-0" PLAN TRUE
NORTH NORTH
10'-3
17'-11 " 20'-0"
94'-3"
A5.2
7
5'-0"
N
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920 A2-O.dwg
SHEET TITLE
PROPOSED
BASEMENT LEVEL
PLAN
SCALE: 1/4" = V-0"
A2.0
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWlAND-BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
N
HytijgNq
A44EY
T RANSFORMR
R
SITE PLAN - PROPOSED
SCALE: 1/8" = 1'-0"
/ N
AREA/6F BUILDING
ENCROACHMENT PER
ENCROACHMENT
AGREEMENT BK. 426 PG. 527
,AND PLAT BK. 13 PG. 86
(TITLE EXC. #9,13)
APPROXIMATE LOCATION OF
WATER QUALITY VAULT.
PERMANENT ENCROACHMENT !'
PERMIT REQUIRED FOR
LOCATION OF VAULT IN R.O.W.
RE: CIVIL
ALL LANDSCAPING OCCURS
WITHIN THE CITY OF ASPEN
R.O.W.-FINAL LANDSCAPE
PLAN TO BE DESIGNED AND
VERIFIED WITH PARKS
DEPARTMENT, CITY STAFF
AND HPC MONITOR.
i
.................................. ........................
...................................
.................................. ...........
.................................
........................................ ..........................
........................................
...............I........................ ..........................
.................. .......
......................................... ..........................
..........................
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
/ Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920 Al-1.dwg
SHEET TITLE
PROPOSED
SITE PLAN
SCALE: 1/8" = T-0"
A1. 1
COPYRIGHT 2010 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN, NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.
O
y
RENDERING IS FOR INFORMATION ONLY AND MAY NOT FULLY REPRESENT THE FINAL PRODUCT
CRANDALL BUILDING
24 MARCH 201 0 -HPC FINAL APPLICATION
29 MARCH 2010 -FINAL REVISIONS
s
UI
rowland + broughton
architecture and urban design
117 s. monarch st.
3377 blake st, 106
aspen, co 81611
denver, co 80205
970.544.9006 v
303.308.1373 v
970.544.3473 f
303.308.1375 f
Consultants
Issue:
29 MARCH 2010
HPC FINAL -APPROVED REVISIONS
C ..
�'' F '`oJa'i)
THE CRANDALL
BUILDING
630 E. HYMAN AVENUE
ASPEN, CO 81611
PROJECT NO:
2920
DWG FILE:
2920_AO-O.dwg
SHEET TITLE
COVER
SHEET
SCALE: N.T.S
um
COPYRIGHT 2010 ROWLAND-BROUGHTON ARCHITECTURE AND URBAN DESIGN
THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS
THE PROPERTY OF ROWiAND-BROUGHTON ARCHITECTURE AND URBAN
DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR
WRITTEN PERMISSION OF ROWLAND+�BROUGHTON ARCHITECTURE AND URBAN
DESIGN. ROWlAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL
RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,
INCLUDING COPYRIGHT THERETO.