Loading...
HomeMy WebLinkAboutLand Use Case.500 S Galena Ave.1978-PD-1 . -. , ... ...,.~,.~-----....,.-,------..~.."-,, .-, ___n ____ ___ . ___ Copland Hagma, w Ltd Architects PO Box 2736 Aspen Cola 81611 303 9252867 March 14, 1978 Aspen Planning and Zoning Commission Ci ty Hall 130 South Galena Street Aspen, Colorado 81611 RE: GMP POINT EVALUATION RESIDENTIAL SECTION Dear Sirs: To reserve our option for further discussion with Aspen City Council regarding exceptions we take with methodologies, evaluations and GMP point awards by the Planning Office on GMP residential appli- cations, we wish to place this letter on the record of P and Z proceedings March 14, 1978. The following is a brief itemized discussion of points we wish to be considered by City Council: 1.500 South Galena/925 Durant project This project is a single submission comprised of development on two separate land parcels. Evaluation guidelines do not contemplate review method for this type of project. Planning office evaluated this project by considering a single GMP catagory for both portions of the project simultaneously, thus the total project point award was reduced to the lowest point level given to the individual project portion. This method tends to mask the merits on one part and not give a true evaluation of its worth or deficiency. A more equitable method of evaluation would be to evaluate each of the two development portions of the submission separately and on its own merits in accord- ance with GMP guidelines. The total point award would then be added together and divided by 2 to reach the total project point award. This would allow fair and unbias point awards as contemplated by GMP guidelines, yet would permit the deficiencies or merits of each portion to average out the other. Copland Hagmal N LId Architects Letter to Aspen Planning & Zoning Comm. March 13, 1978 Page 2 2.Water Points not awarded consistant with criteria. 925 Durant Project and Goodnough project location separated by only 2 city lots yet were awarded different points. 3.Fire Protection Points not awarded consistant with criteria. 925 Durant project and Goodnough project location separated by only 2 city lots, yet were awarded different points. 4. Public Transportation Points not awarded consistant with criteria. Only projects that "improve level of Public Transportation Service" should be awarded 2 points: projects that may be handled by existing level of service awarded only 1 point. 5.Recycle Facilities Points not awarded consistant with stated criteria. Goodnough project awarded 2 points for providing recycling material bins: other projects provided identical facilities awarded only 1 point. Park Central project awarded 1 point and did not provide on-site recycle facilities. 6. Handicap provisions Points not awarded consistant with stated criteria. Different point awards to projects that provide identical elements for handicap. No point award recognition of projects that make special (non-required) provision for the handicapped. 7. proximity to Commercial Facilities Points not awarded consistant with criteria. None of the submitted projects "in and of itself improves the level of (commercial proximity) service in a given area", therefore should all be awarded only 1 point. Respectively submitted, La~~, COPLAND HAGMAN YAW LTD JLY/lls REFERRAL TO: Asp'::n Fi re Di s tri ct FROM: -Aspen/Pitkin Planning Office RE: Analysis of Impact on the Aspen Fire Department DATE:: The Aspen/Pitkin Planning OFfice is reviewing a development proposal, and requires an analysis of the proposal's impact on the capacity of thle fi re department faci 1 ity by consi deri ng the abil ity of the Fi re Department to provide fire protection according to the established response standards of the appropriate district without the necessity wff establishing a new station or requiring addition of major equipment tID an existing station. r lJlre attached app 1 i ca ti on form i dentifi es the 1 ocati on, si ze and type 'of development. Please review the application and indicate the category ~f impact below. . 'coj"" 5'a>"i. ~ +- 91S 'P~4..;R- Referra 1 Submission Date:. If( fC-c..# '71 The proposed project will have the following type of impact on the capacity of the Fire Department. 1-:; Negligible impact - substantial excess capacity exists to provide fire protection according to the established response standards of the appropriate district without the necessity of establishing a new station or requiring addition of major equipment (such as hydrants, wet standpipes, etc.) to an existing station. .lJL Moderate impact - only moderate capacity exists to provide fire protection according to the establ'ished response standards of the appropriate district without the necessity of establishing a nel1 station or requiring addition of major equipment (such as hydrants, \'iet standpipes, etc.) to an existing station~ ~, . I~ ~ubstan!.i21J.!11l>.act - thi s development wi 11 over- Durden the capacity of the fire department to provide fire protection according to the established response standards of the appropriate district without the necessity of est.ablishing a new station or requiring addition of major equipment (such as hydl'ants, wet standpipes, etc.) ~o an existing station. Ii' Comment~;;: '" ,-~ ~=-- .~-==---=====.:=.==:===---- - Si""""" _.~~ . ~~=-~-~~l-t.('-_i~~~i& '''' !{[I[!:i"\! 1 0: k'I'.t ~ . r "': ~(lrd tatic(i r,.~ ~ lJ::" i. FI{C::'~ . fl,~~;/r .;tijn f"j2.nn'!tl:J OfC-ice' k~~: /\n(J:Y~>-;.s of lr:l:)(Jct on SC'\"(l~E~ Trcc.lLi::;:-it Capacity 1.1F,TF; February 5, 1978 "--"--"-' -_. ...._.~---_....~-_..----_..__._..._---_._~._--_.._--~. ._---_...~----_._._--_._---- The !\spen/Fitkir: !)I('JJlninCT Office is rC'vi 2'\',,1 i":'_1 c de'lclopnv~nt ptoposal, c_:ncl r(~qui n:;s i:qj i5.r\?i.l 'j s of thr~ nroposa 11 s i ct on th~ cZlpaci ty of the SC',:i'l(!C trc'citr;icnt fete 'iit)' by cU;-ls-iderit:~l exc(::;s c>JP:lcity of the sy~~tern, 'j OCi:: ti 011 of the :learest 'tfWlk li;" COlHH:>ct-j n~_] se'\'!er l'i n2. The .tJ.--- -.1-, (' at)t)'l'c'a')''-'f' f:o',',n'l l,~!<);..,J-l'.r.:C'- J"I~f' lcr-"{-~on ^l'ZP r: L_clL:iL i .t r I I" u,' I : I; U'_,I{~ i !.....~ L::_--: ~,o....l ~.)-~ of develor:ilcnt. P'lc~sc l~eview tl1e application &lld indicnte of impact bel OVi. and type the ca teCjO\'j' Pro'; eel :;;.I2O.SoutlJ..JiaJ.enaJ 925_ Durant.L~J.!bmi Ued by COQl~llil.~.J:!.agman&.J.~W) !(eferrDl Suh';ii ss i on t(-:: _ FebruaryJ,~,,~.91J:L__________. The pr'O:Josed project \',~ill have th'2 follcf,/ing t;/PE: of 'in~i)act on the C(!\l~C";ty of the sewage treatment system. /~ !iQ.gJ.igiblp,-J":~.~J ~ substantial excess capacity ex'ists at the se'\.'Ja~)c: tfb3.nnent plant ar:d at the n(~arest tl~unk or conncct-ing ::e\'.'er' line to accoliFncddtE~ this develoV:lent. /=; Hoderate 'irm~u('t - only r~:ode(atr.: capacity exists ?it "C'"th-;'-s"',;"-n';;-'-:"j-"-l-" ;- ,,1- '1[' 01' i1 " "I"g. t'-Ile 11'0"1"''''' t .,~ ..\.,"u.c ... U l. I' ,('_I. , --'- ~ij ...U,~'_,~, trunk or"conn:-:cti ns; S':;VJC\" 1'] l1e to dCCOilil;lodaie thi s deve 1 cp:nent. t>1 Stlbstant~: ;':1 i~~n\:),_(;t .-, thi s <levelopClcnt \-,.ri 11 over- bu~:'(ft~'n'-.tf)'(;; ~(-_.. - - 'iT" of the SCi';(')Y' tn~Jii.-I~cnent pli1llt or ttlC Ilear'~st t"J11!( Ol~ cun:lpcting s~'wer 1il1e. Coniillen ts: .__c:::.'/l...J\~iJ:::/-_______..s._E.L.iLl-c-~____L$-__.L~_~-~l_I"?.~.c..__l~-------2t:i_E...._____.~ 1'-\ L-e.......1\- . . A4 '7 -'1.'." /)~.~~ A . S:.1:fl. ,;;; P7" ___ ,e..LI:::E:....-I'Y.E.!!.&_.Li-~J-::.Li """,,- ...c.,-_-,_..l='./:i.il:;.iL..L~_..L-fL..--'2-~-. " ,...,^=> .L'-'-...J....JJ.S.,.ALC1:;._..-k.G:.Afl,....--Ztt~'O~,,"'-~~.LL..E.~Ji. rJ_c tJ,g'c_!3:...d...-2e- 11-/ C c.g..~ fOE !LI.:L..____..____.. -.. -.'O----.---- ------.--.---..-.-.-.-.~._--.-- TJl- ~..L'1~}J..!_~.":_'__ TI=' ,"" ?<1.f::?~A ....Ll:A.iZ.E.r:.__.b.Lr,cE._.E.t:i:~J.....l. '-..r <l r H e :)i~ll1;itlJr, _~_~._ .A..i.h ../'if"_~j{L' [liilc ___.L t: /3___.1.':6. /17 I? MI'-'- STilE,;;.' ~/-I~ ~/1IC/~ Af'f>C'/jtc4 Tv,'3t: /-lA-,_C. l'.eu0~(J''7.s tvlll+ A ~"rri-"""C'"':-lG Jvl/6-~e_ IT /'11 Sfe~ TH,e o'-'?- 1+ rHe:. itt..venA~ rAKc?"- I~Y TI-/e (':>I$-7"""<r 70 .s'Vj3!>/v,slO- SIEI'S ;\Ii!-,; I'>?II'-C- //-.Jv~Srt?-t+rE. ,rfl< f'RoJ{';,~ert )J.....~ S o i--......'T I ",..-,5. /0 Co",/!!: vf" i-v,trl fOtJ~>//".>i-e... r?j.A~1 CAf>AC.,"t'/ IS 0'-'rFlCLer-1 '-- .") .: t: f) A. '-tc- F 0 (L C-vr{r1p;-T.'. ov C;'; r- buR-A '-I n[F[Pi~r\\. ---,'~-,~ -'~----.' --....--...---........-.-- ,-_.,._-----_._--,--,.~'_.- -- ---,~.._-----_.--_.~. ._._-_..,_._~. --..-...--.--'-.- ,_._-------' ...- TO: fL;JC:(! Po') icc' rJ(':p;j('tm,,:'1~ F!,Oi.1: !\SVn/Pitk"i rr 1'1 ,.nn i w; Offi cC' r<E: !\nJ.-ly';i:; of Irnpact on thl: Aspen \\).: ice D~2.pzn-tr:lcnt DM [ : February 5, 1978 . -.---.--.---.---.-------'---.-.----- -.. ._. _._._-,-_..._--_._...-----_...__.-'--~.>-"--"- -.------..-..- l-hc r\Sp(~,I/P;tkif! F"lanning O-Ffic(~ is reViC\Finq ;:1 d('j~,:,'lcprlent propose!, 2nd rcql,:itc:-; (,:r! 2;n~,i'l)s'j.r, 0-[: Lh i:')'Opo,:\-;'l'~~ ir~;pdct on the cap:icit,y of the !\~;li{'(: l'ol';ce rt::ncflt l:.:\' cons'idc:'"ilil,l th~~ ab'j'iity of CUY'\,,(:llt pol-ice:" sccut"ity SCT'.!'1CeS to ~)':O\J';d2 pcotc:(~t';un dCCor'c.l-ing to rea~~QnbQle resp(in::,~ stDfic!;-.)!~d::. thout U:2 nccess"ity of (;~dd-iti()n~-il faeiliti(0s~ personnel or equ'i fie The attDc!l:::':d appl iCi:jtion fonl: iduitifies the locat'irJIl ~ sii:!2 and type of development. Plc(.,si2 revic\',' the appliLCiti.on and 'in(licCl1:e the cute0or'y of ilnpact beloA. Project: 500 SO!lth Galena &~~Dur-E-nL(g;bmiJ;J;ed ~9Jlland.L Haqman & Yaw) Referriil Submission Datre: February l4.,..l~ZfL._.___.___________._. The prqJOsed project Vii 11 have the fo11o\'.'ing type of impact on ti,e capacity of the Aspcn Police Department: CJ t~5"DJ.i9ipl~u.il:li).G:t - suhstuitial eXC2SS cap2cHy en, cs consideriL9 the ribility of current pol--ice secu.;""'ity services '[.0 provicie protectioll according to re2soilable l"c;sponsc sta 1".:,15 \"iithout the n2cc~ssity of addi- tional fncili'Lics, p~rsonl'iel or equipmcllt. /~ t~~?~l~rC1_!_~._.1n ct - on-IY mDderat.e c(":rJc\,city e"~cists COil'. sider.ing thc:~ a lity of curr'cnt l,'D'j-icc :-;Gcurity services to provide pro~:ection acccll'ding to reJSOflCble respoiise sL~nd(n'd~~ \:; th;iUt tric' llt::CC:SS i ~S' of acdi.- ti ollill facili ti ('5, pcrc,orlnel or equ"! pnlcn1:- ~y_b...:~_!~~:i2..t.t~L__11:,'.J~~~t - this dcvelorimcnt \',rill over- burden tIll: V,L;-; 'l'j t.v of current po l'j ce securi ty servi c[-~s to provide protection aceol"ding to reasonahle y'eSI)OllSC stalldards \vithc)ut tIle necessity of additioi)al fac:i 1 i ti cs ~ rh~i"'5onne 1 or' equi p:11cnt. Q.Q (; ~ HI>> li~N' l COlnllCIl ts: "&i ecL&a'l___~ .. )'QJL~ ~v..~f.:'_ ~'=,~0~~Lii-l f1oL(l ~{L.l!L{'f _..~}L _JJ,B,___ 0?!::'.Q ,<deL.JL'i-._l11L. ~ / /L,/1-(J.f.-~-~:f13::~'4-~-- I . I .' tt~ ' , 1_.J:t()fh.wull.-.~4_./lPl~.~..AI.L..JlLiR.Iji.c,.<n( . t11:'JCl.,~J6-_._ <1i'5-..k. 14/YlJJ,)L~<e... ~JlIINleR'TL'l JlL _G?HUd"?f1-.--h. _f11'i_ __E C(;,/f~!:ttL___tJ;>{I~(,c4 ~~~:~l::,:~ :1J-~-~U1 !..~f::~: ' ;;')1- ~ ___.IfL(~ ...... . ......1- C! - 1 . . P,E~'r:EHr"L , TO: r(;:I(;1 City Ln~.;i'ie{;r' rhU:-1: r,~ 'Il/P;t~:il': rlliln~:ing Offic;e [\[: f\ti0 "is 01 Impilct Oil SI/)]'llI IJrainuT', i'i:r'kili~1 DcsiUn, and I:oarl, DI\T[ : February 5, 1978 . ---.---,..-.".-.-- _.~-- -~_._-_.._.._-_._..._-", -.-- .--_.~-. .- ---,_..---_.---.-.~.._.--_...>_._~-~----- -.--..' -,--<-,--"-"--'-~- The /\spe;-;/f)'it!~.;:: p'jt:;:i'I'~n(j Off-jc:.; i'-~ l'c'rlc:'./ing i1 d;~vC'lo:-,;ncnt pre;-'Ds;il, -I"rl l~r'~lL'-:'; ~-(. "I) ":'I,~,")'.lc-'c"-'{If 1_\ (.\ Il"-.,,:,n,,,;:,'] \(; "II:")~-!r'" P'I ""fir' C-)'-"~C'-~ ()e,' C.<I-.J . '."j! I. '....' 0.. U .'--, ',j _' I.J ~ L-I.,_ - ~"r"I.~.'u,,- ,Ii-. ~"l, j, ... (~':/"" j . storill c;Y':-;li-:~'qC~ 'iij~j i~jn~ c),-t:J rCiHL, cunsi(~c:i''' Ul(~ caprjCity of th;~ ~,'ii'lage ,r,. !'l';'~";(\::, to u3tc'ly C;i:;PD7.C of trlt~ sutf(;c~ runoff; COilS1 . 'jliG th::: j(i;::)'; l'it,;/" C'T d0siijii ur of'r-"-strc:ct park-inD or-ens;, c<1d cuns"ic!~Tin0 the c;:~;Jc:.c-it,s cf i',-\;jor st:"c:et 1 inkClJc:. ~1-hE; c1ti,ciChc-:d dppl'ic;}i.':-;cn form .i'~ont'ific::s the locaL'io;-\~ s.iz(~ und type of dcv(;l _.nt. Ple(<::[\ rC"I'j(-,;'! -Chi'.: r.lpp1icat'jon and ind-;cat(;; the eCi ory of -imDcct be:lu.-'/. prOj2~rt; 50Q2.oJ11h_2.a,l ena..~__~~Jlbmi tted bY.C9..pJ~...Jiagman..MJLYaw) R.efen'i 1 S ss i en Diite: ...!'.~~ruarYJ~"..J~7!L_____.___._____.__n__.__ lbr::. ,I,.. O~ . , . cd project \',111-1 have Up:,':' fOil ng type of irilp3,c'L on L:hc ccp~cit.\/ STOHl'l: DRP\Ii' ;t! NC:~11i9';hlc iL'!7;d,Ct - subst2nti(i'1 (::>.CCSS C2D=~.'>it.Y.' ex'1:::,tr) T(J1"~-'ai:-(j,~:iil-~"~l-~;~---ri:'Erl'itic:s to oCkqU(it:~'!,\1 d-1 ~i(\:~~; l'y ti,:".~ surf2c:e ,(,ull(d~r of ichc \il"Op:,sE:d ~jcvc--,'jU~-i;;iL::it \, ,';~!1(1:,!t . ' ' l "tl ~ !!' '1' sY~>j.:m CXTE:nSlon~) -)ej.'())"j(J - nose nC1l'rriCli l}' 'l:-l~-c.(~.. 1 the deve 1 op(:.'r'. by r/ f/18C1(T2Itr-' in;[';"! -. 0nly nnder(~i~t-" CL~ ci t,Y l2xi sts for 111'''~~i"i1i-~j"e'7t1.c L:-; 2S t~) i-;l~equi<te'iy d'] spo:.;e of t.hl2 . , i "'I t' " " Sl!Y'!, ace l"Ui'; D-l tlC: V'ODO::,C:(.l CF:ve CO;1Jl?n - \'.11 {1't~IU '.: system extcl,~~ior1s iJ(:~.'>'()nd thuSE: norm:-:lly insta'I';e;j by the d(~vc'l orcr b /] Sll.!~:_St(I~1J..tLt3J.-_~.1~)~..1.0-~t, .- th i s d(~v e 1 oP:!It';'nt vI'i 11 ovcr- Durden the clipacity of the draina~j2 facilities ';:,0 ilucqui1tely eli -'pose of 1 he Slll'fc1ce ITnJff of the p!'opClsed dc;vE' 1 up:I1:~nt vri thout. sys tom extcns i OilS br'yond those IID,'nullyin,tilllcd by the develope'\', Comments: ._~"__.~.~._v_!!!!~--#-..- ff1-- r-Il. ~ ' .. ----JJ.-L--.~--._"._.._.~.-----~-- - --, - -~-..-..-'-' - ...-.- ,~-...".---..~---~-----."...-..-.-.-- ------_.~._-----_._._-~ ---".----, ... ---.-- .'----._----,.. ---- --------.-.,-,------.-.-' ,-_._--.~._.__.- "._.~._-- _______ _,_. .__ ~_o.__._.,._~.__,_._" -.--~- -,,- ..--------.-. ----.-..--. ,~----.,- -.. -.,,-----.-..-.....-'- _._~,----- tt.__ _._ _.___~....__.__ - -"'--" ..... '''...------. --...- -"..---~-,,-.-.,-..-,-- -.-.--.---.-. -.-. - -I ~~ f~' .' ........,....... ['I\I.'f;:.r: I," ".- - ~ - (/ nC:S1.Li!rLh'l.(:j.~\I' (I.~. :,:,:) ~,L;'it-iill cxcr,'~~; (oPdC it)' px-j'_;t:_; '-(or' 1h(~ (i;:_,"ii}!'1 fJ-i rlr' iy'nct, fHY'i~irn ilrCd'; v!ith r~-(i-'-' to v'i~.,u;,l;jI .-;(::"., (,:~:. n-;:- fl;iVLJ ~;u('fu.cc ~ cUllvcn'iclii_J: c!fld ~-;i_dc i y civ" l;J l~or]CI'(,t(' 11', ~1 - (,or 1'. !jOJ')I~{L(' ((1flJ(,it~' l/lS1S for th(\ dC:.:'jf::i off-~~p(::,,-:~ pi -ing ,:rrCi)~, \,!-itf"l YC~;p~":ct to v-i~,u(;'i -;'I':r_i.:-.ct, (d:,i ',i., of IJ(JVc.ci surftlCC, CDIT-.:c:n-jel1':..:C dlld ~-,(J';f: t.y (:/-i ts. I] SIJhstan1:-iiil i ct - this dcvel ~:ill Qver- blJ-i::(]r.'I\ I;~: LC;)(ICr{.~/ -((l~' tl:e dc(;i (In of ofi-"-<:;-~.rcet P;l\ k-inq c':(, ,-...~; ~.iit~1 rec;r:c:ci.. to visuill 'illq-)tlCt., {:!ili.lUnt of l)(.:\.jccl ~_~L;r'fc~(e, conv;~ri'icncc ;:,(1(\ Sc.rC'L':/ (~:.::.-ic:;. ::::.?~~~........._~~ ROf~D3 CJ Neqi i(;i~)lc 'ii'i>1Ct - suL):~.t2ljtic'1 c;<cess cc<_p2c'ity e>:i,:t~'; --_.._---~.,......,~--,_...- ,-~-- ~---- - ---~ io provide for the n s of the r1-oposed d~v~lup~211t viithout ~,ub:.;-l~i:nti()-~'ly ~_ltc\,'-iiig ex.;:)ti;19 tr'i~ffic p2.t.tertIS or o\/c('lo;:,d-it:J tht:; existin~_! stv'~' '~: :-;ystem or tile nE~C(:,sr)-ji_~y of p\'C\/-id-in~~ inCf'f;';SCO 'l_kd i1rj'iE'aq~~ '/'''--' ~. '.-~-..." ~,r.r~ ant! UJ Ilkll!L_\.J(J".....l. p ct - modci~~:.te cap~city exists for the ,-,. "1 ,,, , ' " t' 'I' !J1"OpO.S:Cu C~!V~:-: OP':1::::iil: vnr.rl(;ur St~L1S'Ldn 'li~ IY altcr-;nq cj;-istin'J trcl';--fic pi.i.~-tC\ti~-; Ot~ o\lc(-lo(~d;tI~l th(~ exist'jrl~: S-l.f',-:et ~,ystf:r:! or' the nccc,ss'ity of r:r-ov'idin~1 -!il('ri__'c:'~ed j'"ej3d m~l~: 2.)1d/ot-' L1~;':ili,:c'naf)Ce. i/iCJdrfi:rc; i)e(~'cfs ---(l"f CJ SU1",:',tDnt-; '1 i t "" t,his ch"lvE'1 n t \'f'j '11 C.'I L1Y'- bunk:n the c,'fJ?C fv of the c:-:i ~;i:'j n~J tTi~ 1'\ C' p~;ttern') ~ or the ()vcl>lo'::Ld'in~) of tile e>("i~,t.in0 stXt'c:t \'r'::;tC;;i, or the n2cc~;::ity of pr-o'./-idinS ilic.Te{;,~;ed r\I,:_,.d In-iled~lC' and/or 111aintt'-:iiancc:. Commcnts :~----~~-.~k~<' ~......&.. .0-:!~.cf.....i) &f-;-_~";:~:';2 ,~1:dk--.~~~ ._~..._.b_....____ .~_~~u _____.~ ~---~---:-~_.~.MI~-..~-&f_-. '~~'-'-'--"'-'- $i '1"'" "'c_.._---.!.u:-n-~.- .. [)" i l' J.- !r 3/7 ,P - .~--". -'''.,-- -"-"-f.-~'- ".-...-.,,-,.. '. -,.~---_..- ....._, - ? ' ~-......., '\".. i , rzFr [i{\Z/\L _.~~._----' ,,--~-----~-,._--"--"--"'-" TO: Ci ty 0"1' Ii:) ~<!utcY' , ('~~;:(; Ii t FRO:1: l\spcri/!'itkirl Plcnn-ii"l(i nf-;:'lc(: R[: Analysis of Impo.ct on the: e>.ist.] \<bt:~~'( sY'Jtem and cdpacit.y D!\T[: February 5, 1978 -----~~,--~"'-,.,"..~,_._-----'-_..~--~----"--,... " ---,---'""-,-"'----"-----~._-"----_._.._.._------'- -.. Th(: /\sD0n/PiU',':n P"lannill'-l Off-ice "is 1"2\'-:(:\.' il:rj ,~; a,ncl rCClu'irr:s ;:11) .::1Jl(llssis' of the pr()n(jsd'l'~:, --; of ovai'lab"!r; v::-;tcY' ctnd i ct on \':at',?( !Ht:_'--:;;U('L: [nairl or cOllilectirlg line. d2\'cl(ji)~~2nt i~r'oposrtl t on tii2 C'V(:Y'ij"! 'j C,: OfiJ th0 r~~2rcs1: v:~tel~ The Dttached a!_)p-licotion.fo~'Yl id(;nti1~-ic~:. tl-,? locc:.t-;,(!i-j, s'i~_~ and type of devc:lopn;::nt. P"lci:se rOVle,.) the C;Ppl-](:(-itlOi-! 2.,1:d ltjOiCal.,e tr;C Ci\tC(jD\"Y of inl[J3ct below. IJroj [iCt: 2Q.(L~ou1:h Ga 1 ena_.&..Jlz.!,i_j).l!ran.t.lli.bolU.te(Lby..c.upJ~<L. J:ia~marLLYaw) Hefetrc~ 1 Subm-i 5S.; on Date: ___E~J'-rlljlx.Y_1iI__19}"a._______~_.-___~_ .---"---.------~--~ The Py'oposed pr-oject vii 11 h:l ve the fo! 1 Q\li 119 type of i mpil ct on th(:; cap0.ci ty of the sev,lage trC'i./ciilcric syste':i: 'f!1 .~ ::uhs.t:anticl.'] (~XCGSS \'l0,tC;j' cap'::icity nci, 01~~1}' a rct wate~' pressure of the nf: ares t V:;:,_ ter rno. in m" c:onncc ti ~, ""I' ~,-~\LI_.i~l exists in th2 vicinity water 1 i ,1[', o i't - on']v 1.il~1ited,vrater C2,iJ2citv (-',<-ist~; ~~ , UI"(:. ".,.,'1' 110 '1L::-Q,.--!-,,,"] -'\1 :'-ho '-~-'-CJt ..56.-.. ccA , ,._.) ._ \, I I ", C (., . '.'_'V__U I ,"".....1IIj; 1);;';;;"" O(fe:~l(il1(!p~.~% SlIhstClir.J",-, il1il,'Ct ' th'i, of've,l Iii 11 (1' ('\',Irc':'r! 't'h~;-\<,:;--i":- "~'.:",',.,""cl-~('.:'";",;",r:,-'~.,T,, 1"1' ?Il"i ,"1"{~ s("'~nl!r-l\.' l'l~'!!:Je.~, thr' C .. ,-', <, '_ ., " _' ,..:1 L.- ',II'" ,1' __ c,,~) '"' .~,' .- '- ' .... pi~C~;SU~':: "j )-: -l:h:,: nC(~i'C:::; t J1;:d n (Ii"' CC'~l!d~C l>~: V.-';,"Lc:r 1 i lie. " , FIOde1"0te CO:T:i:ients: H", q .... Tit~:~=7'r;-=2;;;';'=-;l. ~ ~ ----'--- ----- ;- ~ ~~ - "'---. ~. -- - -,- -- ----- -;;/iIL;;-- - --- _____~-----~-'Z1.J9' hO ..' '"---- \ , --,''', ---,.,-,-.--', --- , rY _,.,e_71J~pr !L.t(~ - R"-":"~ 1 -. - ~~, \ ' :1- . , '._ "j~'t .." .-;.:;;:'~ I I I I -.... - --- Copland Hagr 31~-:',l LId Archl\ocl. i'() il,,,, ;'136 M~'en COI01) ;1611 303 ':)25 2867 March 14, 1978 Aspen Planning and Zoning commission Ci ty Hall 130 South Galena Street Aspen, Colorado 81611 RE: GMP POINT EVALUATION RESIDENTIAL SECTION Dear Sirs: To reserve our option for further discussion with Aspen City Council regarding exceptions we take with methodologies, evaluations and GMP point awards by the Planning Office on GMP residential appli- cations, we wish to place this letter on the record of P and Z proceedings March 14, 1978. The following is a brief itemized discussion of points we wish to be considered by City council: 1,500 South Galena/925 Durant Project This project is a single suvmission comprised of development on two separate land parcels. Evaluation guidelines do not contemplate review method for this type of project. Planning office evaluated this project by considering a single GMP catagory for both portions of the project simul taneously, thus the total project point award ~;as reduced to the lowest point level given to the individual project portion. This nwthod tends to mask the merits on one part and not give a true evaluation of its worth or deficiency. A more equitable method of evaluation would be to evaluate each of the two development portions of the submission separately and on its own merits in accord- ance \vi th G~lP guidelines. The total point award \vould then be added together and divided by 2 to reach the total project point award. This would allow fair and unbias point awards as contemplated by GMP guidelines, yet would permit the deficiencies or merits of each portion to average out the other. Copland Hagmane> LId Architects o Letter to Aspen Planning & Zoning Comm. March 13, 1978 Page 2 2.Water Points not awarded consistant with criteria. 925 Durant Project and Goodnough project location separated by only 2 city lots yet were awarded different points. 3.Fire Protection I. I I I Points not awarded consistant with criteria. 925 Durant Project and Goodnough project location separated by only 2 city lots, yet were awarded different points. 4. PUblic Transportation Points not awarded consistant with criteria. Only projects that "improve level of Public Transportation Service" should be awarded 2 points: projects that may be handled by existing level of service awarded only 1 point. 5.Recycle Facilities Points not awarded consistant with stated criteria. Goodnough project awarded 2 points for providing recycling material bins; other projects provided identical facilities awarded only 1 point. Park Central project awarded 1 point and did not provide on-site recycle facilities. 6. Handicap Provisions Points not awarded consistant with stated criteria. Different point awards. to projects that provide identical elements for handicap. No point award recognition of projects that make special (non-required) provision for the handicapped. 7. proximity to Commercial Facilities Points not awarded consistant with criteria. None of the submitted projects "in and of itself improves the level of (commercial proximity) service in a given area", therefore should all be awarded only 1 point. Respectively submitted, La~~' COPLAND HAGMAN YAW LTD JLY/lls -. 0 0 I C I I I I I 500 S. GALENA 925 DURANT COMI3INED PROJECT' c GROWTH MANAGEMENT PLAN SUBMISSION o o o Growth Management Plan Submission I I I I I c 500 S. Galena 925 Durant Combined Project GENERAL REVIEW INTRODUCTION Submitted for GMP review as one project this submission con- sists of development planning on two separate land parcels: The 500 S. Galena portion of the project on which (16) free-market units and (1) employee unit are planned; the 925 Durant portion of the project on which (12) low income studio units a rc planned. The respective locations of the two project entities are shown on the Project location map, following page. 10 I I The review criteria denoted in the Growth Management Allotment Application is basically, and most easily, structured for evaluation of a project proposed for development on a single land parcel. To facilitate review and evaluation of this project, which combines development on two land parcels, we have submitted each develop- ment component in a separate section of this portfolio. Each of the two parcels proposed for development have been treated in- dividually as to their respective compliance with GMP criteria. The 500 S. Galena portion is discussed in the first portion of the submission and the 925 Durant portion in the latter portion. I I I I I I o I I I I I o o o 500 S. Galena 925 Durant Combined Project Growth Management Plan Submission I I I APPROVAL REQUEST The 1975 Aspen Employee Survey clearly demonstrated that 52% of the employees surveyed had household incomes less than $10,000 per year. This group is mainly comprised of the support employee, a significantly large and important group to Aspen's economic structure. These employees have been disenfranchised by the un- availability of adequate housing at a price they can afford. c An important aspect of this project is the focus on housing needs for the low income employee. Of the 29 total units proposed 45% (13 units) are designed and designated to meet lower income needs. The merit of the low income housing provided by this project cannot be measured, only, as a percentage of total units. Their more important value in meeting the low income need must consider that quality and size of space (form) is being provided at rental rates even lower than contemplated by the Growth Management guidelines. I Applying the standard used by the Planning Office, i. e. 30% of gross income spent on housing, this project creates housing for 26 em- ployees (double occupancy per housing unit) with a salary of $4000 per year. The designated unit rent of $175 - $200 per month is significantly lower than can be justified by normal development economics. I I The unit distribution proposed for this project purposely creates employee housing remote from the free market units. The four lot site, in the RMF zone, allows the development of larger studio units (425 s. f.) with more open space amenity, thus a higher quality em- ployee product. Rather than being located supportive of a specific employer, the low-income units may, at this location, address the employee groups at large. I I o This project offers major and immediate relief for the employee housing deficit at a location within walking distance of all employ- ment, shopping, and recreational destinations. If approved by GMP review, construction of the low income housing will begin immediately and prior to construction of any free market units, which will be phased voluntarily. I I I , o o c 500 S. Galena 925 Durant Combined Project I I I Growth Management Plan Submission In view of the urgent need for low income housing such as this project will immediately provide, we urge that City Council authorize, for this project, the construction of additional em- ployee units as permitted by Section 24-10.10 of Ordinance 48. (Series of 1977). c I o I - - c ~ ~Q7 ~::: O~== ~ ~..' -==--= I I ..... 925 Durant Project ,I r Ie > I - Jt 0--- I I ~ ~ I 600 ~ I o 200 400 , I III . < ;;II 500 S. ~^LE",!NA';' , ~ '-"j~" PROJECT GIONth Management Plan Submission o o ,.... .. 500 S. Galena Project Growth Management Plan Submission Submitted to: City of Aspen Planning Department 130 South Galena Street Aspen, Colorado Applicant: Mr. Hans Cantrup P. O. Box 388 Aspen, Colorado c I , Architect: Copland I1agman Yaw Ltd 210 South Galena Street Aspen, Colorado I I I I c I I o o I OJ 3 go i - .~ cQ' ~ 500 S. Galena Project Growth Management Plan Submission INTRa DUCTO R Y 1. Project Name: 2. Location: 3. Pa rcel Size: 4. Current Zoning District: 5. Zoning which Application is filed under: 6. Maximum Buildout under Current Zoning: 7. Total Number of Units Proposed and Bedroom Mix: 8. Size of Units: 9. Price Range for Sale or Rent: " 500 S. Galena Project 500 South Galena Street City of Aspen 21,600 Sq. Ft. L-2 Zone, City of Aspen (RMF permitted use) L-2 Zone using RMF Option 21 studio units or 16 one-bedroom units and 1 studio unit 17 units total, comprised of (16) one-bedroom free market units and (1) studio employee unit (a) one-bedroom free market units @ 1000.1200 s. f. each (b) studio employee unit @ 600 s. f. (a) one-bedroom condominium units sold at current market price (b) studio employee unit (manager) rented at $175 per month c I 500 S. Galena Project Growth Management Plan Submission 10. Program Narrative: The site is planned to maximize open space, landscaped at the public corner of the parcel and to permit the functional organi- zation of two basic building groups comprised of (16) free market units, in a massing configuration compatible with neighborhood scale and pedestrian movement. Consistant with open space objectives the majority of required parking is designed for a subgrade location. This additionally permits weather free movement from vehicle to individual unit. Buildings are designed in a two level stacked configuration with individual unit plans canted at 300 to permit solar and view orientation up the mountain and to further reduce the massing by the staggered building form. The architecture of the buildings is characterized by sloped roofs stepped in relation to grade change, the use of native stone, cedar siding, exposed wood beam exterior elements and projecting balcony elements. The site will be completely landscaped to create privacy and to create a corner green space relating to pedestrian movement. The floor area ratio permitted by zoning for this project is FAR 1:1 or, 21,600 s. f. of building development. As designed, the total project uses approximately 18,500 s. f., or 85% of the allowed FAR. 11. Description of Surrounding Zoning and Land Uses As shown on the Vicinity Map, the project is located at 500 South Galena Street in the L-2 zone. Surrounding zoning is L-2. Surrounding land uses are a mix of lodges, commercial facilities, multi -family and Single-family units. Immediately surrounding complexes are the Tippler Inn & Lodge, Continental Inn, Alpenblick Inn, and Durant Condominiums. ~- -~-~--- RIlE 5f.'Jl0l.j HI&fIWoIY BL!r-w~ 5f.---i EXI5Tl~ t'W.L s \ll6HEJ1: I'm< ~f!IQ<.5OO1lloI w.> I'!UfE roruIT1II. ~ LmP LIFT I.A Lf11L~ ~~LL LIFT ~ CllY 1l<.IIL I"<OJELT SITE. &A1.EfJA SIlIEEr MILL sn<fEr a CGl'IMtnU\L em: ~ CCMMEJll:LAL LOC6t [, '] LOrGE l . .... rnrrn 1\E5I~}.[l1,AL .17' LOroE III I%KjFUellG Vicinity Map ~ o 200 4K)() 800 ~ AGMAN YAW LTO ARCHITECTS A STREET PROJECT COPLANO H THE SOD SOUTH GALEN A"f" 'Ca'o "I" Jre~ -1 l ) -~ ~ ::::~~ J~... l~ lrt-... ~"" ..... (I."n,n. I...,I"........,..'''...H..........~''III ~""" ~ ~- 2jt-..,. '''~'''f UIl1l~ I~~ 4~ ALre~ IlLICK IVTCIJlW. ~ Lalf' Site Context r-\...o-" o 200 400 , ... U11LE f,Eu. fl:LL LIfT lllTLf. INIl llm.E I..l:(l';E sreer- 5l.lnS t:trNIl"WCOS ~ THE SOD SOUTH GALENA STREET PROJECT COPL.AND HAGMAN YAW LTC ARCHITECTS A ,,, en'" " -,...... NORTH Of NELL , <?jD:~ ~....J :~, ,/-~' . ~-,~-, " DEAN AVENUE CONTINENTAL INN ,-' , , , , , , , , , '-- I I I I I , , L~___, ~~__I , , I- W W a: I- lJ) '" Z W -' '" " US SITE PLAN ~ 01020 40 80 , , E1 , , , ~ I I ,_- \ ./ ./ ./ /'/' /' / / / /' / / "I / / / -- -, I I I I I 1 I I I I I I I I I I I I I 1- I I I I I I I I ----1 ~___I I I l I- UJ UJ a:: I- 00 <t Z UJ ...J <t " cJi Unit Plan 500 $. GALENA S~ PROJECT ~ r1...-l o 10 20 I 80 40 I I Underground Parking Plan 500 S.GALENA S~ PROJECT ~ '''" "" Surface Parking for 7 Cars I- W W " t; ct Z W -I ct CJ ~ -i ~ ~ !-- r1.-l o 10 20 40 ( "-- /-\ recycling. center. V /' I "-,,- I "- I I , , I I I I , , I I I ~ Underground , I Parking I I (. 10 Cars , I I I , ...., elevator I I ----t I 80 ~ 3Nn A1l:l;!~~_ ',\', 'J; -->:~~ " jot-- , .:~~ ... W w a: Iii c( Z W oJ c( Cl :z: ... ::l o UI ::E o a: ... z o j: o w UI .... Z o ~ :> w oJ W iNn Ail:l3clOYd \ F: "---"" "', ~ ARCH ITECTURAL ~ o 5 ~ ~ ~ l-"'" ~ . ~ 90 o ","oU o o o T F Typical Unit Plan 500 S. GALENA Size 1000 -1200 s.t. Sale Market Price ~ n....J 024 I 8 I 16 o o "2 '2: l'5' ~ < ~. I ,-, 500 S. Galena Project Growth Management Plan Submission PUBLIC SERVICES (aa) Water System The evaluation is the capacity of the public water system to pro- vide for the needs of the proposed development without treatment plant or other facility upgrading beyond those provided by the developer. The project water demand is directly related to the fixture unit count, consisting of 300 F. U., which converts to 80 GF'l\1 maxi- mum probable current ASHRE guide standards. The 6" C.l. P. water main located in Galena Street, adjacent to the project site, will provide good flow and pressure to the project development. A project review by Mr. James Markalunus indicates that no fore- seeable deficiencies exist with regard to providing water service at adequate pressure levels and no substantive impact on the treat- ment plant, which is currently utilized at approximately 75% capacity, will result from the project development. Reference A. Site Context Map, this section B. Prcject review letter from Mr. James J. Markalunus, Aspen Water Department, this section (bb) Sewer System The evaluation is the capacity of the public sewage disposal system to serve the proposed development without system extensions and without treatment plan upgrading. The project site is served by an existing 8" sewer line in serviceable condition extending up S. Galena Street and located directly adjacent to the project site. 500 S. Galena Project Growth Management Plan Submission Applying the Colorado State Department of Health standard of 100/gal. /day /person to project occupancy standards of 1. 5 per- sons per one-bedroom unit and 1. 25 persons per studio unit, the total project would generate only 2600 gallons per day. This would add less than 1/7 of one percent to the plant capacity, thus is well within the service capability of the present capacity. A preliminary project review by Mr. Heiko Kuhn indicates that no foreseeable deficiencies exist with regard to providing sewage service to this project and no substantive impact on the treatment plant, which is currently utilized at approximately 75% capacity, will result from this project development. Reference A. Site Context Map, this section B. Project review letter from Mr. Heiko Kuhn, District Manager, Aspen Sanitation District, this section (cc) Storm Drainage The evaluation is the capacity of drainage facilities to adequately dispose of surface runoff without public drainage system expansion. The drainage control system for this project will collect and retain all site runoff and interrupted subsurface flow with on -site drainage facilities. The project shall have a serie,s of dry wells and retention wells sufficiently sized to retain and disperse site surface and roof water runoff. Consistant with standard engineering practice, the drywells will have overflow outlets extending to S. Galena Street. A planted diversion berm will be created at the uphill side of the project to divert excessive surface drainage away from building development that would result from abnormal precipitation. Reference A. Site Plan; Physical Design and Program section , 500 S. Galena Project Growth Management Plan Submission (dd) Fire Protection The evaluation is the ability of the Fire Department to provide fire response to the project according to the established response standards. The project site is located approximately 1300 L. F. (4 city blocks) from the fire station and can expect a maximum response time of minutes from alert siren to equipment arrival at site fire location. The project development will provide an on-site fire hydrant which, in addition to serving this project, will upgrade the protection system for the immediate neighborhood. The building development will be additionally protected by a dry standpipe system, completely sprinkle red parking garage and ionic smoke detection in individual units. A project review by Mr. Willard Clapper indicated no foreseeable deficiencies exist with regard to fire protection. Reference: A. Project Vicinity Map, this section B. Site Plan, Physical Design and Program section C. Project review letter by Mr. Willard C. Clapper, Chief, Aspen Volunteer Fire Department (ee) Parking Design The evaluation is the design of required parking with respect to visual impact, exposed paving, convenience and safety. The majority of the required on-site parking (1 space per unit = 17 spaces) has been located in an underground parking structure below the residential units. The parking structure will provide for 10 of the required spaces and the remaining 7 spaces will be provided as surface parking screened by landscaped earth berms. All parking has immediate and level pedestrian access to the pro- ject elevator as well as access stairs. "'...., < .. 500 S. Galena Proj ect Growth Management Plan Submission Reference A. Site Plan; Physical Design and Program Section B. Parking Plan; Physical Design and Program Section (ff) Roads The evaluation is the capacity of existing roads to service project generated traffic without substantially overloading or altering existing traffic patterns. As shown on the Site Context Drawing, this section, the pro- ject is located on Galena Street approximately one block south of Durant A venue. Examination of the traffic impact of the project is primarily based on work generated by the UMTA transportation study and on recent conversations with Mr. Steve Lockwood, Alan M. Voorhees & Assoc., Inc., traffic consultant for the UMTA study. The table below presents the trip type and trip frequencies per day per unit for a project unit as estimated by Mr. Lockwood. The 6.5 trips per unit is less than the 10.0 trips per unit for a typical residential unit, because the project consists of one- bedroom units generating less people than larger apartment or condominium units. Total trips are estimated between automobile and non-automobile trips. Estimated Trip Type Estimated Non-Automobile Estimated Non- One-Way Trips Trip Percentage Automobile Trips Skiing/ Recreation* .75 60% .5 Work 2.00 75% 1.5 Shopping and 1. 25 75% .9 Entertainment Personal Business 1. 00 50% .5 Other 1. 50 ~ . 4 6.50 60% average 3.8 "". ,/ 500 S. Galena Project Growth Management Plan Submission *The 60% non-automobile average for recreation trips assumes approximatey 75%-80% of ski trips are non-automobile but only 50-55% of summer recreation trips are non-automobile. Due to the project's immediately convenient location to downtown Aspen, Little Nell Lift and Rubey Park ski buses, it is estimated a high percentage (60% to 75%) of skiing, work, shopping and entertainment trips will be non-automobile trips. As shown, potentially 60% of the total projected trips per unit will be non-automobile trips. The estimated 2.8 automobile one-way trips per day are equivalent to a resident's using his car on an average of approximately one time per day. The walking and public transportation convenience of the project's location plus the project's low resident population results in minimal traffic impact created by the project. Current detail traffic counts are not available for the area to quantitatively estimate traffic impact. Reference: A. Site Context Map, this section (gg) Energy The evaluation is ability of the project, its spaces and users, to maximize the conservation of energy. Consistant with the solar geography of the site, all project con- struction will be designed and built to maximize solar utilization and to minimize heat loss, thus reducing the demand placed on the fossil fuel resource for space heating. The following techniques will be implemented in this project. Insulation Significantly exceeding regulatory thermal standards, exterior walls will be insulated to R=26 to 28 min. ; roof composites to R=42; floor composite to R=20, foundation perimeters to R=14. ".'" '-' "'", " ./- -' 500 S. Galena Project Growth Management Plan Submission Architectural Architectural design configures buildings to optimize thermal characteristics of the project. Exterior wall ex!X>sure is mini- mized by staggered unit concept (common wall), and by vertical space organization (minimum ratio of exterior surfaces per sq. ft. of occupied space). All buildings are oriented with highest use interior spaces to the south to achieve view while maximizing passive solar heating !X>tential. Glazed openings on non-south exposures will be limited to Uniform Building Code minimums (to comply with ventilation re- quirements). Opening surround details will be required to mini- mize heat loss due to infiltration. Partial flat roof surfaces are designed for all units to retain the additional insulation value of snowfall layers. Devices Consistant with solar geography of site, solar collectors will be utilized for domestic hot water heating. Electric energy will be designated for primary space heating to reduce fossil fuel demand. (approximately 50% of electric !X>wer used in Aspen area is hydro- generated). Automatic thermostats will be specified to control night time space temperatures. Fire place design will use double damper control, exterior comoostion air, glazed fire opening, and heat return ducting. Humidification will be used to reduce temperature required to achieve equal comfort levels. Reference: A. Architectural Drawings; Physical Design and Program Section UFT I.A -) H16H\.AY eZ/M'J~ ST.----i EXI5T1~& t"ALLS W6NE!': mx P:IW I'N<K 5ImlIl [;UIl;AI(f AVEflUE w.; I'l?Jre um.. ~LL LIFT I!1TWl1Il. ~ LmI' rww.w CllY T1<AIL m:>JECT SITE eALEIJA sno:eET MILL '5TlIeET . W1MtI\C.LIIL un ~ CQ1ME~ ~ l""""1 Lor&E: l ~ [ill]] ~vef.lTW..1 7- LOI)Sf. mil 1m.!f'UeI..IG Vicinity Map ~ o 200 400 800 ~ CO~LAND HAGMAN YAW LTC A~CHITECTS THE SOD SOUTH GALENA STREET PROJECT A 'p' n Col" ,,10 IUeYmK 51ATlQ\.l~ romrr A'lElUO+ E ( ~ J JrE-7 .-l 1 1 -~ ~ LITTLe IoI:LL ~cc LIfT CClITl~eIlW. I~~ TImE. IIlIl T11!'lf.~ ALre~ fL\C.K STllP' 5Wl"ES ~= rvru-JTW. ~ l.COf' ~~:~I~ ~/ Site Context ~ o 200 400 800 THE 500 SOUTH GALENA STREET PROJECT COPLANO HAGMAN YAW LTO ARCHITECTS A..p,n C:olo""oo - "".,.",~ ~-_. ...., ,i/ January 25, 1978 Mr. Larry Yaw copland Hagman Yaw Ltd P.O. Box 2736 Aspen, colorado 81611 RE: 500 South Galena project Dear Mr. Yaw: I have reviewed the development proposal for the above referenced project, which I understand to consist of 16 one-bedroom condominium units and 1 studio employee unit. The project site is presently served by a 6" C.I.P. water main, which is located adjacent to the site, and it continues up South Galena Street where it loops with a 6" water main aligned in Mill Street. The two nearest hydrants are located on Durant Street and are No. 102 and No. 103. They have tested static pressures of 92 psi and 94 psi respectively. I estimate the new hydrant to be provided by developer (per city of Aspen specifications) and adjacent to the project site to yield approximately 85 psi static pressure and a flow of approximately 2000 g.p.m. It is my opinion that the development proposed for this site poses no foreseeable deficiencies related to water service. l"Y ,"u , ii~ (]::: ~ " j ,I January 25, 1978 Mr. Larry Yaw Copland Hagman Yaw Ltd P.O. Box 2736 Aspen, Colorado 81611 RE: PROPOSED 500 GALENA PROJECT Dear Mr. Yaw: I have reviewed the development proposal for the subject project with regard to fire protection. I understand the project to consist of (16) one-bedroom condominium units and (1) studio employee unit. The two nearest fire hydrants, No. 102 and No. 103, are located approximately one city block distant on Durant Avenue and have tested static pressures of 92 psi and 94 psi, respectively. A new hydrant will be located adjacent to the project site, which is estimated to yield approximately 85 psi static pressure and a flow of 2000 G.P.M. The location of hydrants relative to this project permits good coverage at adequate pressure levels and augments the ability of the Fire Department to serve the neighboring structures. The site plan indicates that fire vehicles and equipment will have good access to the project from two streets in addition to the roadway access provided for a portion of the on-site parking. The location of the project relative to the fire station permits the prompt response time necessary to deal with fire related problems. It is my opinion that the development proposed for this site poses no foreseeable deficiencies related to fire protection. Very truly yours, -) , '(< ,(/ / ( ,j;;' f. // (,' 1 'f. [" / f Willard C.' Clapper / / Chief, Aspen Volunteer Fire Department A~EN SANITATION DIS I ~ICT P. O. Box 528 Tele. 925.3601 ASPEN, COLORADO 81611 ,.;.......,0>'" January 30, 1978 Mr. Larry Yaw Copland Hagman P. O. Box 2736 Aspen, Colorado Yaw Ltd 81611 RE: PROPOSED 500 SOUTH GALENA PROJECT Dear Mr. Yaw: I have reviewed the above referenced project with regard to the quality of sewer service to the proposed building development. I understand the project to consist of (16) one-bedroom condominium units and (1) studio employee uni t. The project is presently served by an 8" sewer line in serviceable con- dition, extending up South Galena Street adjacent to the project site. The present sewer plant capacity is 2.0 million gallons per day (M.G.D.), which is presently utilized at approxomately 1,569 M.G.D., or 75% of capacity. A new addition to the plant in 1980 will increase plant capa- city by an additional 1.0 M.G.D. Applying the Colorado State Department of Health standard of 100 gall dayl person to project occupancy standards of 1.5 persons per one-bedroom unit and 1.25 persons per studio unit, the total project would generate less than 2600 gallons per day. This would add less than 1/7 of one percent to the utilization of present capacity. Due to the uncertainty of the total number of proposed units and their locations under the Growth Management Plan, the total impact of the approved units on the collection sewer lines can not be evaluated until such time as the information for all projects under the Growth Management Plan is available. There presently exists sufficient plant capacity to treat the proposed proj ecL If there are any questions, please contact this office. Very truly yours, ~~.- He i ko Kuhn District Manager, Aspen Sanitation District o o .' .-: ( ~ - =a: I' go , i' ,- 500 S. Galena Project Growth Management Plan Submission SOCIAL FACILITIES AND SERVICES (aa) Public Transportation The evaluation is the ability of the project to be serviced by public transportation. As shown on the Vicinity Map, this section, the project is located 350 feet from the Durant Avenue bus route and the Rubey Park Transit Station. These distances equate to a I! minute walking distance, thus easily accessible. Reference A. Project Vicinity Map; this section B. Site Plan; Physical Design and Program Section (bb) Police Protection The evaluation is the ability of the Police Department to provide normal protection services to the project with current personnel and equipment. Conversations with Aspen Police Department personnel indicate the average response time to this proj ect would be I-I! minutes and that this project would not extend present patrol routes. No additional police personel will be required to provide normal protective services to the project. The project is bounded on two sides by public roadways thus facilitating access and visual control from patrol vehicles. Additionally, a private security patrol service will be retained on a continuing basis to provide normal protective services thus reducing the frequency necessary for public police patrol. Reference A. Site Plan; Physical Design and Program Section /,....,. v 500 S. Galena Project Growth Management Plan Submission (cc) Child Care Facilities The evaluation is the provision of a child care facility within the Proj ect. A child care facility will be provided for this project. Space requirements will conform to the Minimum Rules and Regulations for Child Care Centers - Colorado State Department of Social Services. In addition to interior space and outdoor play area provided for the project generated children (ages 1-8), the child care facility will be large enough to absorb certain of the needs of the im- mediate neighborhood. Ms. Terry End, Director of the Aspen Montessori School, will serve as consultant to this element of the project. (dd) Bicycle/Pedestrian Paths The evaluation is the location of the project relative to pedestrian and bicycle path systems. The project is located 1 block (120 ft. ) from the proposed City bike and pedestrian trail and approximately 450 ft. to the Galena Street pedestrian mall. As shown on the Site Vicinity Map, this section, these systems are within easy pedestrian access of the Project. Additionally connecting to the City sidwalk system, the Project development will provide sidewalks along the S. Galena Street perimeter of the site. Reference A. Site Vicinity Map; this section B. Site Plan; Physical Design and Program Section . ~ ., ..... f .. 500 S. Galena Project Growth Management Plan Submission (ee) Recycling Facilities The evaluation is the provision of refuse recycling facilities in the project development. Such facilities will be provided in the park garage portion of the project, conveniently accessible to both occupants and pick up of the separated refuse by the recycle center vehicle. Consistant with the recommendation of Mr. Dennis Holmes of the City Recycling Center the Project will have separate containers for glass, tin, aluminum, and newspapers in a location accessible to a parked 5 ton flatbed truck, 20 feet long. (ff) Design Features for the Handicapped The evaluation is the ability of the project to accommodate safe, convenient movement for handicapped persons. The site and building design will permit unobstructed movement (for a wheel chair confined person) from any location in the covered parking garage to virtually every condominium unit. This is accomplished by means of hydraulic elevator and path surfaces which will not exceed a slope of 1: 15 (U. B. C. requirement). Reference A. Site Plan; Physical Design and Program Section B. Floor Plan; Physical Design and Program Section (gg) Proximity to Commercial Support Facilities The evaluation is convenient walking distance from the project to commercial support facilities. ,y""'" .. 500 S. Galena Project Growth Management Plan Submission This project is located! block from the C-C Zone and approxi- mately 450 feet (l! minutes walking distance) from the Galena Street Mall, thus are easily accessible pedestrian destinations from the project. Reference A. Site Vicinity Map; this section c ... - 500 S. Galena Project Growth Management Plan Submission EMPLOYEE HOUSING The evaluation is the percentage of low income housing units provided by the development. 45% of the total project units are designated as low income housing. For detailed information on the employee housing proposal for this project see the Social Facilities and Services Section; 925 Durant project submission, following. -FI~ 51AnON HI&HW\Yl3t(M'J~ 5T.--i EXl'5Tl~& MlUS 1U6NEl': mK ~M<.5lAf1t1.l W?1'rUl'E fl7ml1l/I. eo'.> La?!" UFT I.A -) rumrr AVE~UE LlT1LE. ~E.LL LIFT ~D CI1Y Ti'AlL I"<OJECT ~ &ALBlA 5ll':EET MILL ST1<l:ET . COMME:rLIAL CCfi: ~ CCl1ME:f'W>L LroSf e: :1 LDWE: l []]]] n:51~f.lTW. .1'7. LDWE I1IlIm./rueLIc Vicinity Map ~ o 200 400 800 ~ ~ I(\.Wfm 5VJl0\.l~ lIlmtr A'iBUE~ e , Hl!mIr J Jre-~ ~l l -~ ~ LlTlLE Io-ell. r1ml-I1W. elb I.LZJl" fJELL LIfT CCIl11~6WJ.. IIIll TImE ~ llmE I.lX:GE ALrE~ llLU- 5TUP' 5Un:S PJl'IIlr= Site Context r-~ o 000 "'" , 800 r.:~"\ ~ THE 500 SOUTH GALENA STREET PROJECT COPL.AND HAGMAN YAW LTO ARCHITECTS A"f" " C"lo~ ,do o o " " . 925 DURANT PRQJECr Grovvth Management Plan Submission 925 Durant Project Growth Management Plan Submission Submitted to: City of Aspen Planning Department 130 South Galena Street Aspen, Colorado Applicant: Mr. Hans Cantrup P. O. Box 388 Aspen, Colorado Architect: Copland Hagman Yaw Ltd 210 South Galena Street Aspen, Colorado ""'"" . 500 S. Galena 925 Durant Combined Project Growth Management Plan Submission GENERAL REVlEW INTRODUCTION Submitted for GMP review as one project this submission con- sists of development planning on two separate land parcels: The 500 S. Galena portion of the project on which (16) free- market units and (1) employee unit are planned; the 925 Durant portion of the project on which (12) low income studio units are planned. The respective locations of the two project entities are shown on the Project location map, following page. The review criteria denoted in the Growth Management Allotment Application is basically, and most easily, structured for evlaua- tion of a project proposed for development on a single land parcel. To facilitate review and evaluation of this project, which combines development on two land parcels, we have submitted each develop- ment component in a separate section of this portfolio. Each of the two parcels proposed for development have been treated in- dividually as to their respective compliance with GMP criteria. The 500 S. Galena portion is discussed in the first portion of the submission and the 925 Durant portion in this portion. o o I ii1 3 Qo f. - J :J 4 925 Durant Project Growth Management Plan Submission INTRODUCTORY 1. Project Name: 925 Durant Project 2. Location: Lots F, G, H, I: Block 119 City of Aspen 3. Parcel Size: 12,000 sq. ft. 4. Current Zoning District: RMF, City of Aspen 5. Zoning Under Which Application is Filed: RMF, City of Aspen 6. Maximum Buildout Under Current Zoning: 12 Studio units 7. Total Number of Units Proposed and Bedroom Mix: 12 low-income studio units 8. Size of Units: Studio employee unit @ 425 square feet each 9. Price Range for Sale or Rent: Studio employee unit rented at $175 per month 925 Durant Project Growth Management Plan Submission 10. Program Narrative The site plan is organized to create maximum open space fronting on the public (Durant Ave.) side of the project development and to permit the staggered architectural form which relates to the residential scale characterizing the majority of structures in the immediate neighoorhood. The building is organized in a 2-level stacking arrangement with in- dividual unit plans staggered to permit multiple view orientation and to further reduce building scale. Consistant with convenience and visual objectives the required on-site parking is located to the alley side of the building immediately adjacent to covered paths and access stairs to the individual units. Utilizing contemporary forms and components/the architecture of the building accomplishes a victorian scale in its facade elements. Masonry bearing walls, wood siding, and projecting balcony elements characterize the exterior design of the building. The site will be landscaped to create greenspace and privacy for the lower level units. The F. A. R. permitted by zoning is 1: 1 or, 12,000 sq. ft. for this site. The project development, comprised of 7000 sq. ft. in total, uses only 60% of the permitted floor area. The building footprint of 3300 s. f. covers only 27% of the available land parcel. 11. Surrounding Zoning and Land Uses As shown on the Vicinity Map, the project is located on Durant Avenue, east of OrininaI Street. The project and the immediate environs are zoned RMF. 925 Durant Project Growth Management Plan Submission Surrounding land uses are lodges, condominiums, apartment units and assorted Single-family residential units. Building complexes in the immediate surrounds are: The Alpina Haus Lodge; Silverglow Apts. ; Chateau Snow Lodge; Old Hundred Condominiums; and The VagaIxmd Lodge. , ^ /iodp ~,~~ 925 Durant Project r > ~ ~ ~ I 800 ~ I o 200 400 WEST END ST. D OLD ON. '"' rl CO'COM"'" 'U o UJ ~ I- ~ a: ::l o C1 c=J D o I \~ Site Plan 925 DURANT AVE. PROJECT ~ ~ 01020 40 80 I ._Xl - :z: I- a: o z , z o fii > UJ ... UJ :z: o I- UJ :.: l/) ARCHITECTU RAL ~ THE 925 DURANT AVENUE PROJECT COPLANO HAGMAN YAW LTD ARCHITECTS Asp," Colo~,,,,o , cE STUDIO I 1r "~ Typical Unit Plan 925 DURANT PROJECT Size 425 S.1. Rent $ 175 / month ~ I o 2 4 8 I 16 ~ o o ~ C'" - n' ~ < ~. 925 Durant Project Growth Management Plan Submission PUBLIC SERVICES (aa) Water System The evaluation is the capacity of the public water system to provide for the needs of the proposed development without treatment plant or other facility upgrading beyond those provided by the developer. The project water demand is directly related to the fixture unit count, consisting of 144 F. U., which converts to 55 GPM: maximum probable flow (l!" water service) or approximately 100 gal. /day /person as per current ASHRE guide standards. The project is presently served by a 6" water main located in Durant Ave., adjacent to the project site, which will provide good flow at adequate pressure to the proposed development. A project review by Mr. James Maralunus indicates that no fore- seeable deficiencies exist with regard to providing water service at adequate pressure levels and no substantive impact on the treatment plant, which is currently utilized at approximately 75% capacity, will result from the project development. Reference A. Site Context Map, this section B. Project review letter from Mr. James J. Markalunus, Aspen Water Department, this section (bb) Sewer System The evaluation is the capacity of the public sewage disposal system to serve the proposed development without system extensions and without treatment plant upgrading. The project site is served by an existing 8" sewer line in serviceable condition extending along Durant Ave. and located directly adjacent to the project site. ".''''- '\i,., 925 Durant Project Growth Management Plan Submission Applying the Colorado State Department of Health standard of lOa/gal. /day /person to project occupancy standards of 2.0 persons per studio unit, the total project would generate only 2400 gallons per day. This would add less than 1/7 of one percent to the plant capacity. thus is well within the service capability of the present capacity. A preliminary project review by Mr. Heiko Kuhn indicates that no foreseeable deficiencies exist with regard to providing sewage service to this project and no substantive impact on the treatment plant, which is currently utilized at approximately 75% capacity, will result from this project development. Reference A. Site Context Map, this section B. Project review letter from Mr. Heiko Kuhn, District Manager, Aspen Sanitation District, this section (cc) Stann Drainage The evaluation is the capacity of drainage facilities to adequately dispose of surface runoff without public drainage system expansion. The drainage control system for this project will collect and retain all site runoff and interrupted subsurface flow with on-site drainage facilities. The project shall have a series of dry wells and retention water runoff. Consistant with standard engineering practice, the drywells will have overflow outlets extending to Durant Avenue. Reference A. Site Plan; Physical Design and Program Section .''M__-' ........... , '''',/ 925 Durant Project Growth Management Plan Submission (dd) Fire Protection The evaluation is the ability of the Fire Department to provide fire response to the project according to the established response standards. The project site is located approximately 2100 L. F. (5 city blocks) from the fire station and can expect a maximum response time of 4! minutes from alert siren to equipment arrival at site fire location. The project site is served by (2) hydrants with adequate static pres- sure for fire protection. Two adjacent roadways, Durant Avenue and alley way, provide immediate access for fire vehicles. The building development will be additionally protected by a dry standpipe system, and ionic smoke detection in individual units. A project review by Mr. Willard Clapper indicates no foreseeable deficiencies exist with regard to fire protection. Reference: A. Project Vicinity Map, this section B. Site Plan; Physical Design and Program Section C. Project review letter by Mr. Willard C. Clapper Chief, Aspen Volunteer Fire Department (ee) Parking Design The evaluation is the design of required parking with respect to visual impact, exposed paving, convenience and safety. All required parking for this project is located directly off-alley, permitting direct access to individual units via covered walkways and stairways to upper levels. All parking is visually removed from Durant Avenue and public pedestrian routes serving the neighborhood. Reference A. Site Plan, Physical Design & Program Section .-.. "'...... 925 Durant Project Growth Management Plan Submission (ff) Roads The evaluation is the capacity of existing roads to service project traffic without substantially overloading or altering traffic patterns. As shown on the Site Context Drawing, this section, the project is located on Durant Avenue approximately one-half block east of Westend Avenue. Examination of the traffic impact of the project is primarily based on work generated by the UMTA transportation study and on recent conversations with Mr. Steve Lockwood, Alan M. Voorhess & Assoc., rnc., traffic consultant for the UMT A study. The table below presents the trip type and trip frequencies per day per unit for a project unit as estimated by Mr. Lockwood. The 6.5 trips per unit is less than the 10.0 trips per unit for a typical resi- dential unit, because the project consists of studio units generating less people than larger apa rtment or condominium units. Total trips are estimated between automobile and non -automobile trips. Trip Type Estimated One-Way Trips Estimated Non -automobile trip percentage Estimated Non- automlx>ile trips Skiing/ Recreation* .75 60% .5 1. 25 75% 75% 1.5 Work 2.00 Shopping and Entertainment .9 Personal Business 1. 00 50% .5 Other 1. 50 ~ . 4 6.50 60% average 3.8 *The 60% non-automobile average for recreation trips assumes ap- proximately 75%-80% of ski trips are non-automobile hIt only 50%-55% of summer recreation trips are non-automobile. --- - 925 Durant Project Growth Management Plan Submission Due to the project's convenient location to downtown Aspen and public transportation, it is estimated a high percentage (60% to 75%) of skiing, work, shopping and entertainment trips will be non- automobile trips. As shown, potentially 60% of the total projected trips per unit will be non-automobile trips. The estimated 2.8 automobile one- way trips per day are equivalent to a resident's using his car on an average of approximately one time per day. The walking and public transportation convenience of the project's location plus the project's low resident population results in minimal traffice impact created by the project. Current detail traffic counts are not available for the area to quantitatively estimate traffic impact. (gg) Energy The evaluation is ability of the project, its spaces and users, to maximize the conservation of energy. Consistant with the solar geography of the site, all project con- struction will be designed and built to maximize solar utilization and to minimize heat loss, thus reducing the demand placed on the , fossil fuel resource for space heating. The following techniques will be implemented in this project. Insulation Significantly exceeding regulatory thermal standards, exterior walls will be insulated to R=26 to 28 min. ; roof composites to R=42; floor composite to R=20, foundation perimeters to R=14. Architectural Architectural design configures building to optimize thermal cha-racteristics of the project. Exterior wall exposure is mini- mized by maximum unit adjacency (common wall), and by vertical space organization (minimum ratio of exterior surfaces per sq. ft. of occupied space). All buildings are oriented with high use interior spaces to the south to achieve view while maximizing passive solar heating potential. c , 925 Durant Project Growth Management Plan Submission Glazed openings on non-south exposures will be limited to Uniform Building Code minimums (to comply with ventilation requirements). Opening surround details will be required to minimize heat loss due to infiltration. Totallyflat roof surfaces are designed for all units to retain the additional insulation value of snowfall layers. Devices Consistant with solar geography of site, solar collectors will be utilized for domestic hot water heating. Electri.c energy will be designated for primary space heating to reduce fossil fuel demand (approximately 50% of electric power used in Aspen area is hydro-generated). Automatic thermostats will be specified to control night time space temperatures. Fireplace design will use double damper control, exterior combustion air, glazed fire opening, and heat return ducting. Humidification will be used to reduce tem- perature required to achieve equal comfort levels. Reference A. Architectural Drawings; Physical Design and Program Section RI'!: '3rIlJ1ON EXI5Tl~G I"\AJ..L -11~lml\llir- .., 1!l~ - C1UJl(( f'O..E ~ ~~PCrTY TJ<AIL. IiIiI COMMERCw.. COO: _ KESt>1:N1lAl.!MUI:r\-F.M1ILY IIIJill Rf;'3[;fflflPL (p mm K~c;wr1Jl(.. IS _~!/'lItlL1C Vicinity Map ~ o 200 400 800 ~ '-EST E~D smET IJIj I](] lJDCJ CfJArEAU Wo'IlNe ~ ~a.lI5 IN1>WND LDOOE CU> I-\U~D Wi-l1A% DUmrr AIJE~UE ~ t)~ I (IIlIIIIIl dJ ~Tc>.l"\JDU?ES L' TII] - ~ ~ ~~~ ~ ..._0", - .. ALl"lNA K'I5 t'ED'C.'JED ALlEY C~~ ~ 'Om LoreE W/ilUS AVE~UE Site Context ~ 050'100 200 ~ ( " ,/ >"- PEN 130 s January 25, 1978 Mr. Larry Yaw Copland Hagman Yaw Ltd P.O. Box 2736 Aspen, colorado 81611 RE: 925 Durant Project Lots F, G, H, I : Block 119 Dear Mr. Yaw: It is my understanding that the 925 Durant Project is the Employee housing portion of a Growth Management Plan Submission and as such includes 12 studio units. The project site is served by a 6" C.I.P. water main along Durant Avenue, which terminates approximately 130 feet east of the project site, on Durant Avenue. Two existing hydrants, No. 105 and No. 106, are located approximately 215 feet and 150 feet, respectively, from the project site, and they have tested static pressures of 90 psi and 82 psi, respectively. After reviewing the development proposed for this project, it is my determination that an acceptable level of water service can be provided by the existing system. vtry trull your), J 11 dCJ{~ .-- ~. Markalunus /"'..... A~N SANITATION DIS1..1CT P. O. Bo, 528 Tele. 925.360t ASPEN, COLORADO 81611 January 30, 1978 Mr. Larry Yaw Copland Hagman Yaw Ltd P. O. Box 2736 Aspen, Colorado 81611 RE: PROPOSED 925 DURANT PROJECT Dear Mr. Yaw: I have reviewed the subject project with regard to the quality of sewer service available to the proposed building development. It is my under- standing that this project is the employee housing portion of a Growth Management Plan submission and as such, is comprised of (12) studio units. The project is presently served by an 8" sewer line, in serviceable con- dition, located in Durant Avenue adjacent to the project site. The pres- ent sewer plant capacity is 2.0 million gallons per day (M.G,D.) of which capacity is presently utilized to the extent of 1.569 M.G.D., or at 75% of capacity. A new addition to the plant in 1980 will increase plant capacity by an additional 1.0 M.G.D. Applying the Colorado State Department of Health standard of 100 galldayl person to project occupancy standards of 2.0 persons per studio unit, the total project would generate 2400 gallons of waste water per day. This would add less than 1/7 of one percent to the utilization of present capacity. Due to the uncertainty of the total number of proposed units and their locations under the Growth Management Plan, the total impact of the approved units on the collection sewer lines can not be evaluated until such time as the information for all projects under the Growth Management Plan is available. There presently exists sufficient plant capacity to treat the proposed project. If there are any questions, please contact this office. Very truly yours, ~~ He i ko Kuhn District Manager, Aspen Sanitation District -- , - " January 25, 1978 Mr. Larry Yaw Copland Hagman Yaw Ltd P.O. Box 2736 Aspen, Colorado 81611 RE: 925 DURANT PROJECT LOTS F, G, H, I: BLOCK 119 Dear Mr. Yaw: I have reviewed the development proposal for the above referenced project with regard to fire protection. It is my understanding that the project is the employee housing portion of a Growth Management Plan submission which will include (12) studio units on two levels. The two nearest fire hydrants, No. 105 and No. 106, are located within 200 feet of the project site and have tested static pressures of 90 psi and 82 psi, respectively. The location of fire hydrants relative to this project permits good fire coverage with adequate pressure levels. The site plan indicates that fire vehicles will have good access to the project from both Durant Avenue and the alley behind the project. The location of the project relative to the fire station permits the prompt response time necessary to deal with fire related problems. It is my opinion that the development proposed for this site poses no foreseeable deficiencies related to fire protection. Very ~ruly yours, ) ! , ,'/ II i f.< ,; Ii., j f:/{/(:i:' '-'~, wl1~ard C. Clapper Chief, Aspen Volunteer Fire Department o o -, .'1. " 'I ., ~ " r. - ~ - ;::; .0 go '. , I ../ , . o o c 925 Durant Project Growth Management Plan Submission SOCIAL FACILITIES AND SERVICES (aa) Public Transportation The evaluation is the ability of the project to be serviced by public transportation. As shown on the Vicinity Map, this section, the project is located 350 ft. from the East Cooper and Cleveland bus stop and 550 ft. from the Durant Avenue and Original bus stop. Public transportation, thus, is within a 1-1 minute walking distance of this project. Reference !e A. Vicinity Map, this section B. Site Context Map, this section (bb) Police Protection TIle evaluation is the ability of the Police Department to provide normal protection services to the project with current personnel and equipment. Conversations with Aspen Police Department personnel indicate the average response time to this project would be 1-2 minutes and that this project would not extend present patrol routes. No ad- ditiona police personel will be required to provide normal pro- tective services to the project. TIle project is bounded by two roadways (Durant Avenue and the alley way), facilitating access and visual control from patrol vehicles. Additionally, a private security p<1trol service will be retained on a continuing basis to provide normal protective services, thus re- ducing the frequency necessary for public police patrol. Reference o A. Site Context Map, this section , '". j 925 Durant Project Growth Management Plan Submission (cc) Child Care Facilities The evaluation is the provision of a child care facility within the Project. A child care facility will be provided for this project, to be lo- cated at a grade level within the employee housing complex. Space requirements will conform to the Minimum Rules and Regulations for Child Care Centers - Colorado State Department of Social Services. In addition to interior space and outdoor play area provided for the project generated children (ages 1-8), the child care facility will be large enough to absorb certain of the needs of the im- mediate neighborhood. Ms. Terry End, Director of the Aspen Montessori School, will serve as consultant to this element of the project. (dd) Bicycle/Pedestrian Paths The evaluation is the location of the project relative to pedestrian and bicycle path systems. Within easy access of path systems, the project is: 650 ft. from the existing Ute Avenue pedestrian/bicycle trail; 450 ft. to Glory Hole Park; 1600 ft. to the downtown pedestrian mall system. Linking to the city sidewalk system, a sidewalk will be provided by the project development along Durant Avenue. Reference A. Vicinity Map, this section B. Site Plan, Physical Design and Program Section , ,/ " 925 Durant Project Growth Management Plan Submission (ee) Recycling Facilities The evaluation is the provision of refuse recycling facilities in the project development. Such facilities will be provided near the parking area of the project, conveniently accessible to both occupants and pick up of the sep- arated refuse by the recycle center vehicle. Consistant with the recommendation of Mr. Dennis Holmes of the City Recycling Center the project will separate containers for glass, tin, aluminum, and newspapers in a location accessible to a parked 5 ton flatbed truck, 20 feet long. Reference A. Site Plan, Physical Design and Program Section (if) Design Features for the Handicapped The evaluation is the ability of the project to accommodate safe, convenient movement for handicapped persons. The site and building design will permit unobstructed movement (for a wheel chair confined person) from any parking space to the (6) lower level studio units. This is accomplished by walking sur- faces which will not exceed a slope of 1:15 (D. B. C. requirement) Reference A. Site Plan, Physical Design and Program Section (gg) Proximity to Commercial SupPJrt Facilities The evaluation is convenient walking distance from the Project to commercial sUpPJrt facilities. ~,.." 925 Durant Project Growth Management Plan Submission The project is conveniently located I! blocks from the City Market/ Durant Mall and approximately 1600 feet from the downtown pedestrian mall system (5! minutes walking distance). Reference A. Vicinity Map, this section 925 Durant Project Growth Management Plan Submission EMPLOYEE HOUSING The evaluation is the percentage of low and moderate income housing units provided by the development proposal. 45%-59% of project units designated Low Income housing are awarded 12 points. The 925 Durant Project is the employee housing portion of a complete GMP proposal which combines two development locations (925 Durant and 500 S. Galena) as the total project submission. The total project submission is comprised of 29 total units of which 16 units are designated as single bedroom condominiums and 13 units as studio employee units. The project is designed to provide 12 employee units, located at 925 Durant, to the low income employee group at large and I employee unit specifically for managers quarters attendant to 500 South Galena condominiums. As shown by the typical unit plan on this section, each studio unit is approximately 425 s. f. and is additionally supported by common laundry, storage and day care facilities. Larger than normal this studio is designed to accommodate shared living space for a mini- mum of 2 occupants. Upon receiving GMP approval that portion of the project comprising employee housing would be immediately constructed and available for occupancy prior to December, 1978. The employee unit mix and rent structure for this project is sub- mitted as follows: No. % of Total * Annual Total * Annual of total monthly Income monthly Income Units project Designation rent/one Group/ rent/two Group/ units occupant each occupants each occupant occupant 13 45% Low Income $175/mo. $7000/yr. $200/mo. $4000/yr. * Annual income group calculated using 30% of gross annual income allocated to housing cost (Planning Office Standard). ,r . ......., "'".",/' 925 Durant Project Growth Management Plan Submission The rental structure for the employee units is designed to permit a necessary low income support group to maintain affordable housing within walking distance of major employment generators in Aspen. Spending 30% of annual income for rent a single occupant making $7000/yr. may afford a studio or, if sharing a studio, 2 persons making $4000/yr. each can afford a unit in this project. Assuming 100% double occupancy, the (13) units provided would house 26 low income employees whose annual income is $40OO/yr. or greater. This project is within easy walking distance of all major employ- ment, shopping and recreational destinations in Aspen. A total of (12) points is anticipated under the housing section for this project submission. Reference: A. Typical Unit Floor Plan; this section B. Architectural Drawings; Physical Design and Program Section RrE '3TPJ\0f.l W'bNEI: rm\ 1IIIIIIIIIIlllj~'~- ~ ::D~ -0\..DI(yHl!.Ef,>,><:K ~mm,.OEP GllY T~L ~ COMMERCw. C~ _ RE~t;;IOmw.. (MULTI-FAMILY _ RE'SIrElJIlIt (P mID RHCUITlAL- IS _ FMK/fUJLIC Vicinity Map r~1 o 200 400 800 L,,~~'"~':J \~ THE 825 DURANT AVENUE PROJECT COPLANC HAGMAN YAW LTO ARCHITECTS A.pen C:Olo~..do CLD Kuw;nl/ [.O.1[V; lrIJ~'lJDJCJ CfJATEAU IW'l'JN9 ~ A~ENF-> IJ'bIU>I.ID LDroE 1J5T END smET ..._"w - .. K\'t>IW-If r\LI"lNA fl6lF., PJI'AIlI AVENUE ~ I<OI<:IIle ~ An:;. VlOD'{.([E1/ ALLEY ~ sW'. LOreE CIWEAIJ 'ONIM WJEI:!'> AVENUE Site Context ~ 050100 aoo ~ THE 925 DURANT AVENUE PROJECT COPLANO HAGMAN YAW L.TO A~CHITECTS A'll." , C;"ID~n"o ,r-., ",," cB STUDIO 1r Typical Unit Plan 925 DURANT PROJECT Size 425 s.f. Rent $ 175/ month ~ I o 2 4 8 I 16 ~ j Recor:rlcndpd Poi nt All ccat ion , Residential Propusals sc~t- ~:~t ~ Projcct -$l, ,~.- Date YJw /~ /rPr --+--.----- A. Puhlic Facilities and Services (maximum of 21 points - rlaximum of 3 points per rcviev; element). 1. \later Serv i \=e ; , ---~------_._-- ___,___---1-.__ -- .------.- ._- I _.d_____ --------..----------.----- 2. Sewer Service / ------~_._-_.-_.--- ----....----~._._---_._~._. --~=== 3. Storm Drainage ----------,---~. ---------------..-------. -2--- -~_._---._- 4. Fire Protection -_.~-_._---._--------+_.- --.----.---..-----.--.....-.------ --.------ --~ - ~,._._-~---_.__.. -~--- 5. Parking Design -:J!!.' ~~i~_______ 6: Roads ---3---- . ------- -- -..-----------------.------------------- ...------------.--- ---.-.---.- ---..- --.----.-- ---- ----.-----.---..-.-.. --.-~ +._--------_.._--_.__.._-.---~---------_._---_.- -._---_._----_._-~------ --.-3-----. 7. Elle.^CJ:! .---.--.--+ -.-.--..--.,p- ~--- -~-_.__.. ,.------------...-- ---_._-_._.~-~ ---~-_._---_._--_.- _____ _. _._~..__ ,_...____ .__._ _ _ ___ _ _, .__.__ .._.___. h_ ___P ___._._ _~_.. ______~.._._____.__ --~-.--- .. - _~...~. __~._""._._._..~___ ___ _._ - '_' ___ __ - - ._'_' ... _____~__ ,..._ ___u__._ _'__'_' __. __. _ __~...___._..___....._ 1'1 B. Social Facilities and Services (~aximul'l of 1~ ooints) " 1. Public Transportati~n I --"..----..- _______~.__._________~___R_______ -.-~--_._._._-_. ~- ------.--.------- -------------_.~_._-------_.--------------.~_._------ ~--~------- 2. Police Protection _h:JJ_, /Ct(!i{/1L~A-~ -' --.-.-..----- _..------------~----_. 3.~~~:: Facilities, ___.d.. ---- ~ ~lL&:2_ ,lfltl-tJ:f:LLt~ ----,' ----- ~----.---- -_._--~~------------ ------ ---- _._----,.---------_._~-_._-------_.~~--_.- 4. Bicycle Paths ---.-1----- ....------.-----...-...------. --~-----~-----_.- __________._____._____v__.__________ 5. Re~cling Facilities_ , ---~_.._- ,:.;;( 7vJ '/ ':j!:!:t'1/ _ q;z _~~(,~..J-/ n~.t!' ' _._--,--'-_._-~----------------_._-_.._-_._- -------~-----.__._------.._- --d~--, -- 6: HanPjcapped Design Features / t:in~12 J ..dJJL.1t~/KL~ -.-------..-- .-~----_._-- __..........____._ _." .____0 -.------"-.----------..- _._--------~--- 7. co~nercial Support Proximi~y _I ."~._----~. ----------~---- ------_._---_._---_.~---_..- ..--- --_._---p-_..--~--~._-------."_.__._- -~------~---_.-. - .--- --_.-.-- C. Housing (c1aximum of 30 ('oints) 1. i1iddle 2. f'lodera te 3. LO\~ '-/SO) _ /2-: " ---.---. ........---.-.---.-.--.-. . ._.-..__.-~.. - .----..---- _.__.._~.. -.----.-. -.. ~... ---_._--~--.._...-. ______~___.___.._.4__.________. .__ .____..._ 4_' - _... .".._ _..._____~_ _.-. n'_' --..-.------ ... .-, .._.- .-.-.--.-... ..._._-_.~- .._.._._---~--. .-' --...- -., -.--....... ~ ~-~ _.... .-.. -..... ~. ~ .---. .-._-.--.~.- ------ ...- -.-.., - - . -- -... ----"..- . .-' ,. ----. ,,~J Lju Sub Total of,Above,Points Bonus Poi nts l~ F/Jr' tI/72I.U/tl/10I"7ld '7;du[~11 I - ~?llll(l?fc '-/?tu iJi't<-j TOTAL POHl Y- ~ Nal'le '- . , Rcco~lI-:1end('d Point Allccation Residential Proposals Project CjPI) <S' 67fitFNi-/. q'lt; 'l7ul7lWl A. Public Facilities and Services (maximum of 21 points - "maximum of 3 points per revievl element). Date "__~.4e_________ 1. !'later Servi ce ~ -----------------~. ___2::-- _ -- ----_. 2. Sewer Service -------.----- ? 3. Storm Drainage ---------' ~--- _L______ 4. Fire Protection ----_.__._------_..~--~-----_. 5. Parking Design - ?_-- '3 6. Roads ._--~---------------------~-----------~------~-- ---------------- -~------ -~- ,'-. ------------ .._---_.- --.--------.--.----- --~----- ._--~---_.._-.-_.- ----.----.--- -.-----.--.----. ------ "___3__---0 7. Enerr!:: -.----.- . ------..-. -,-,- ------.---. . ------------ .-+ ----.----- -,"---'--- ---- --_..~_. _.....-~. -., - ..---.---.--------- ------ --.--.-- ._--- .-.._-- - -_.._- ---..--------.---.- --.-.------. ... ._ _ _._. ______._._____ _._..~.______ .__'___~'''_'_'' _ .. _..__.____~ 4_ .. _ ..._..__ ,___"____" -----~.-.--- .---.----.. (/'1 .-:! I ,"""'" '-""'-, ",""" " B.. Social Facilitie~ and Services (maximum of l~ 06ints) 1 \ 1. Pub'l i c Transp~rtati r>n ,..-,~i._n i ' ----- ---l~----------=~-=-=~=~='~=~~~=== ---._------_._------_._~ ____L_.. 2. Police Protection =:.~-=== 3. c~ilccare Fac11ities __-L..______,___ --. . _._-------------~------_..------ -----:--=:___z _~: 4. Bicycle Paths -----~.__.~------_._--_.~.._--------_.~.~-~._--.-----_.-- ----~----_._--- ---,._~---~------_. 5. Recycling Facilities _____Z-_.__ - --------------..----- ---.---- .-----------.--- --------~ -_.__._--~--_._----...----- --------------- -_".%-_------- 6. Handicapped Design Features ~---- -- ---------.- 2- 7. Commercial Support Proxjmi~y " /2-- \ ------------_...,--~ ) ----------------.--- --~._------_..._._-.._.-.-- _._--- C. II0using (~laximum of 30 Qoints) 1. i1iddle __ ..1"2/----- 2. 1'1odera te 3. LOIY __._______________.___.__ _. ~__~._____ . - - __.__...__.__.__ ...__..._..._ 0"" _....___ _.____ -... _.~.- ._-_._-,---,_.,-,-",-~"--"-~----'----"" -..,. ---'-"-'--'~'"'- --- ----..-........-.. .-.. .._- .,.- .-....-... ----_._..~-- .-.----,-----..--...- ".-- .-.'-"-.". ,,-_. - - ..... _.---~._-~-_.. . ........-..- ._..-..-~ "',..'.... 4S___: Sub Tbtal of Above Points Bonus Poi nts "2, L 2 'Po fJ fAc: _ll.1JfJ('(: ~ f rJPk.!~--- ~CIAL. - (O,Jirflt -I f-!i1/JD)(','I'?"o) ___. t ()/,tJ IN t'ttvJE f!1M1^.l6.] TOTAL POUlTS 11 fjal!1e (, 0 ~Ur) Recor.!r~end2d Point Allocation Residential Proposals S<>'" ({,<lIe",Q Project f'~s O<l;('4,,-r Date 4111('(' { /</, 1'1).Y / A. Public Facilities and Services (rnaximum of 21 points - maximum of 3 points per revievl element). 1. Water Service L__ -------"--~--_._- ---_._------"----._._-_.~------_._----.-- --_._~- 2. Sel'ier Service ______1__._ 3. Storm Drainage ---~- 4. Fire Protection ...L___ ------.-----....----- ---~._----_._------- _._------~-------~----------.-~----- ------.-- ---~.-- --_._----_._-----~--_.. 5. Parking Desi911 -~ _._----~-----_.._-. _._._--_._-~._--- ---.--- ---"-- --._-- -- 6. Roads n ------=- . ----,._---~----~- ----- -----~-------,------ -.-----.-..----.-------- ~--~-_..._-_.~----_._----_._----.- 7. Ener9.\' ~ ---------~_._-. -------------------.-..------. --------.-------..---.------------.. II ...L ..M__ .-'....... . "'",.,....,;' B. Social Facilities and Services (l'laximuf'l of 1~, ooints) 1. Public Transportation ___--1-._ 2. Police Protection / 3. childcare Facilities _____..0_____ 4. Bicycle Paths __.__L...._ 5. Recycling Facilities ___,_....L___ 6. Handicapped Design Features ___1..____, 7. cOI~rnercial Support Proximity ___L__ --------?; C. Housing (maximum of 30 points) 1. i1iddle 2. 1'lodera te 3. Low 'I -_.J.i.&---f 5 . ) Sub Total of Above Points Bonus Poi nts dL o TOTAL porrHS if1 Na~e d ~() (!~ .---....~._. .~-.~..-,~- . \ Rccor.lI~endecj Poi nt A 11 ecati on Residential Proposals ~oo 5.-; C~~'L'.!t";(.'/~) Project! 02-$ .j..k,./.;:;,,'. - '- Date '31/1-/7 cP A. Public Facilities and Services (I~aximum of 21 pOints - maximum of 3 points per review element). 1. \ia ter Serv i ce 2- ._---- ------------------------ 2. Sewer Service ----L__ _ 3. Storm Drainage __~1...___ 4. Fire Protection Z- -----_.._--------_._---~---- ~~_._-- --.-.------.-----.- 5. Parking Design _3___ -~'-------_._----_.._-------- 6. Roads 7 7. Enei"9Y ---3--- -------.--------------.-- (jiJ- , ) B. Social Facilities and Services (maximu~ of 14 Doints) 1. Public Transportation ~___L_ 2. Police Protection __1 3. chilccare Facilitip.s ----_.~._- 4. Bicycle Paths L- I -------~- 5. Recyclir.g Facilities 6. Handicapped Design Features 2 7. Commercial Support Proximi~y 2- -:::::::::::;..-----.-- - ----70)- (-~-- C. Housing (r:1aximum of 30 points) 1. t1iddle 2. foloderat, ~ -7,-;;-- r --~--- ?~. J F,-. -. '7, . 4 ~- /. 17;.:7 ; wt, t' ,,' ~'. <.; 2 .: (Ir -: .. _~. ..,... ) , Sub Total of Above Points Bonus Points TOTAL porrJTS 1;; Nal'1e 0~;: r;" /,,' . 1 S I Project ~ ~tr --- A. Public Facilities and Services (maximum of 21 points - maximum of 3 points per review element). Recor.Jr.1endt'd Point Allccation Residential Proposals Date t I1AI". ' Lf ~-WML-_LB__ 1. ~ater Servi~e , 2. '. 2. Sewer Service 2 -------- - 3. Storm Drainage _3___ 2.____ 4. Fire Protection 2- 5. Parking Design '3 6.' Roads -------~ -~-.--~---- ---.-_. -~----'__'__' ..__.__.___.______.__r ,._.___ .__.--~--~~.~-------------- -~--_._---_._------- 7. Enei"9Y -.3-- -----. _._---~,-- --.----.- .'- - .--_._-----.-.'-----_.-_.._- --------_._-~_._~- -.--"- /l - .~._.-.._---._-_._---_.._._-~...- .----.._._-.*... _..-----..- ..-....--..-- .._-- ._~- ~--_.._.~--_.._-_._-_. \ ,,-,,"" B. Social Facilities and Services (:'1aXimUl'lof 14 Doints) 1. Public Transportatirn 2. Police Protection . 3. chilccare Facilities 4. Bicycle Paths .~-----_._--------_._--~-------- 5. Recycling Facilities 6. Handicapped Design Features 1____ ~__L__. ___L____ ~ -----~-_. __.b_____ _..1______ 7. Commercial Support Proximi~.'1 ----------....-------.......- --_.__._-------~._---....-._- _._---- C. Housing (maximum 'of 30 j)oints) 1. i1iddle 2. r'10dera te 3. LO\~ l~pl /' --,._._._._---_.-.__._-~ _.~_..,---~-~. -. --_.~._.. -L___. !to -----------.- -----..---.--.---.. ~-. - --_.~--------_._._.__._._.__.. --- --.-..-.--- .-.- _._.~._- '.,- ---~ - --. .--. . -~. ---. '--'--'" ~ . . ._..- ....' .- '.-- - .-- -- '. .- ....-.. -. .-- -. '...-- '-~_. ~ '. ._~-- _~_______~._._,.__~_.___. F'__ _ .. ...__ .___. ___._.._._~________.__. ._." _ ._........,_. .__..~__.._ - " I Sub T~tal of Abo~e Points ~1 _./--'---, Bonus Poi nts --_.--- Nal!1e ~ TOTAL porrns ~ j " . , '\?u t<ccnl::;~l':;n(:C'f! P(Jjn~~ /\-j j(~C,~lt"ICii F(':Jid('nLi(~'l h~(!liu:~dls Project ~ C ,,/i'1';-' "I . ~-_..Y ,: -,'.m..."''": q/.:.-:. ,u()/*.//f-:- Date f\. Public r-0c;liti('>~:.; and ~;C'I'\,'jces (!!1dXiJ!:U:!l of 21. points: l:lC1xiniUil1 of 3 points pCl!" !"cv"ic~\'/ C'!r.::iC;I~_). 1, \_.jot(~l~ :-:~_\rvice Jt'cf-P1i!N:f,.t. :'~,J:'(!.'o^.'!f , _Jc;J..L'~" _CZ/;{<.~; .--/CVfr1:l.d'_'t._ ., .__u . . ___.. ___"_.~.'._.._,__,_ 2. Se~'Jct' S(:l"V -j Cp , _ jjr; ~, . ,,-.- - ~_.- . -- - -- -- ._._~ . j/~/G~7 '-. {'c. :.:.1l. :' l.tZ__ fi1tSi,Ic t;, 3, StOrli1 1;:-aiIFI()p 'r J_ . .:_../ j, . ~-.,r(_.; .' ~~~:_._;"-/tiL~i,'>' , , _:.i.~?-Lcd ( t /'-- l' ")',-,'/'''1.""t ' .._'-,.Le.. v:-./, c.,'.'..''''''. 3 "~..... ,fl.': 4. Fil~e r'rc;tpc:ti(ln , , ,~ AfM1Aill"'('<./.4e/c''/~~ (/;'c " .- ..-.-.,._.," .---... ..-.......~ ~ .." 0I :-.~.. - , I'; I" I I ~"_~'''i,_~. 5. I'Jrkii;\1 1 c.' ~ i dr. t~:i~~~",,,.\.:, "" J:.tJ:,t'.....- {.I"r'.I~'_~~ \' r.~({./-c::.v- 9.:4 5. -f .' v ()<..A.I.'__ , , - ..._~: ~_,>-+...i.J;f... /. " (I :'~.1_c:.L(~J", _1,__ t ,~___,.. _..~ . <16:',CL_,,-?tt~' ~~..!:t_t(~ ~.fC-,C_ f ,j&r'!C!!cC' /~(-,: l 'it:" l~, C'. ~-\UI:; (;~; ..:.. 7' / ~.- '-.!....,<I::f~..;,t,(".: _I ,,' . 17l{~.~-:tc.; j. ~ ././,) ('Ii ~ '--, """,' L \ / .\::". / I ~"'-4.{~":- ~ -,- ......-...-... ,) ;/, - J. fl~i(J" f/.~L' ~ J.-,3B~>' ~~'aJc~mcn fk,ddR~ .~ ,($LI.'cu-(s,ftW~ fI,," 1MttJt;r1 " . ' ,-...I/'" 1 If; ') I;, SOCii,11 r-i:\ci 1-i :"if.", and S(Tv-ic('~~ (:>;,1/::::)[!J'i :Jf 10 ......,,.., !JrJ i nts) 1. J;uhlic TratlS[JOrtati0n , I l/j. _:.. _..~_Ci_'-_~,fj:._ __~. ..},,_'. , , ;/... . "-. '-' < fll~_.._-,-t:!l.l.Jry_jJl L.:' ~ J , I I -" - t A Mv!A" 'C ,--<'.,. , ""-; , + ~ - ,'. - ( .~. , ___ Ja{/,-' :'-',~ .___:>o~/'_ :' - -j.~,-"--,,, > 2. Po 1 i cc' Protect i Oil 'tJ.:) - ,..... ~ t'\ - ,---."'.-,..'----'------ .. I /. ?_. -",~_:(.'". / "I !~T -~ '-':.~ 3. Chi "I <c.:.)re F;,r"; l";t-:(j'_~ J i '': t "" '." "J /. ! ' I ./!/d~t~(PJJ (Zi,-\/.:..;~,.",.." f.i, If', '1( ~~.. . ..A-j~v,tJ.t/L ,,' A' j"cl.:. _. r, ~ ..(.1P;v . '", J. L i < u" ' " I t':- . .6<~'~..i,::_~_,,: (1?~;{;;-;>..::i~; '_~ _'_--~,:~f:'\:,,-~, .~; 'i'-i'~C:-('-' -,t'f~:{: ~~:- ~- . B -i eye 1 e Pat ~ s." - ~ :r. ~--' ,~- /.-\.,. , '" ' . , J ' ~ , , ..I'." I qr."i..,," J "'1./.. t;:.!,...." ~.."'- ' . ~-,"""~C""~.. . ->~-r----( ~~.' .-~~, :...<. -; - -- ---.- , ,. /','A f"" V ,','v/- ,''/ ,), ( .f'v..:._I_'!~_~!-"'-:/-""!:,,'(-~--<, L..::' .>1(....~.2~~~~_:- j /)c"" /-' -'~,~g_. 7..".' , ,., "i".~,t,\,-" (',;C/LI (JJ...! _~Li.':~ J:"'., ,t", It t,"-:)" , ''<;' :" ',..,-" t.<:"-., / '" 7'l:,''''-. ?/;;?,i"Z . _....Ai. _ , ,.. ....'., . ~. f<c\,::/c'l ing .6... rJLili-hc:~ /! / , LiT, {)" ~;{-:ii: i CcJ'!JiwJ D~;,'s i ~Pi ~ ;'tu:is ; _I' _ /l~:" /// ''--<", "..:~," _/-" _ ,,,J. 7. (:(li'li~le~'c i (11 t, It '. -f / '~;-' ",. tf ',' i ( t({ \..({;'" . _.,---. ,...{,/;'i .~.,t~...k j l>~,u ~u: . I !.1\-'f.JX ~ J:: j -:; 'I (!aJI.,; r: i ; c; :):; 'i ~ ~ ,- ; , , 1'12 j: '1 :~i(ji1: c- ,~CI Ll CI i '; t~: ) 5-J.. 9' i:J If ';1':.;; J. r;] d{;-!l // ///-;-; . ~.. ~) :'iudcl"tite ( :i,I~~\0 ....., /3A_I,,'"'i~A/ //r''/,. ..-",{.~~../, -. /./ , , . . ,.... ..,. V..U "'f,Q /0 ,". ()" ( ~ ! ~V- ,- ,;: ...... /.// ./~(,.:;',V./,/,./:l&tL;., I(~, 'I ~...U'f jf '(' . (l(vJ~. It' l...>!!;o....Q/ !'i" .t{.;,~~ L~' .'~. .fll-(.,e:~e>?:,d.~~{~<,j ;/!!'.~,,' / W:I' ,\.~r./ fW- '( ~ct ';;,. i2L..J-;~~ ,/' +, 'i,' ,,: ',__I "(It,,, / 4..., (,4( 'j 'lV.N~; .'"i...J.... A,;Jj',(( ,. '(( /~" ". {' . ........."" SUr) Tot!) "1 () f r,OO\:'e Po; nts Hanus Points , I I -, .-".- ".--- 'I- - .---".-----..--.-...-., -'. ..-~-_..._~._._-----_._--- TOTI\l. PO jliTS /--.........., .:.~' .' ~ ~~I I)' .' , ..' iJal'lf' ,-_,,~.:.::_ ~f--.t' ,/z:{,0.Y '-:'t;,~::ct"'-: ,___ _ '.' . c0 fZ'::, : '76 ,; .C v .,. ~--:-.~ ._----"" .. .-">-.--.... ---..>----.--..-:.?--..:::,: __ _ ..,.,...._o~."'''~,._'"..,^'.._~__ _".,,_",..............,.,.,~..,~'.~,.... q d 5 DL{fQn t- / seD S C;q levtq Hc~n,j (ctn+rc<.ur I) IY18 Gmp Appllcc'{fiGIl l) iJepc{(tvnenf:cd K-e-{e..rnx!s [IrQ ( sqni {ccftOt1I po i I L.e 1 -en9'neet-in~ (Jv(ckr; 3) .scor-1n3 (J(CUltl<rl? O{-+lc:e, Pt-Z, Ll) ~ rnp SWnllS .4 p~c:J~ [)eTor~ Clfl.{ {(Jeer) c.i I Ct) Pre" j vel 4 p(X'{.<i J b) '?CNinq ~he.e+.s ! ('('Lin C II) c) p~ Z. ml n lA.k~ <t- /fcorr,mt'n.dOct(OV1) d\ etA_tne (I mi nut-e.:J en cmP deLis Ion 1-f/'2<{ /7 'i e.) f)udol.l(\j (<-{(Dr-I-- oct- [k(, l('tn, Oec(c(ll., 'X(Jt {'n"! {..') C(~i\tr(tl.-lp 1(J(zu.e::.t -to c.h(tr\qe :OLj ft I fl q:2 '5 DumN LAl'\ib (d<!.l\iEQ cr/I/(18) ,"'" ,. " ....,. ." '-' 500 S. GALENA 925 DURANT COMI3lNED rnOTECT f GHOWTH l'vlANAGEMENT . PLAN SUl3MISSION , ~..... ........... :) " . - ,')00 S. Galena 925 Durant Combi ned Project Growth Management Plan Submission GENERAL REVIEW INTEODUCT[ON Submitted for GMP review as one project this submission con- sists of development planning on two separate land p;ucels: The 50n S. Galena [Xlrtion of the project on which (16) free-ma rket units und (1) employee unit arc plunned; the 925 Durant [Xlrtion of the project on which (12) low income studio units are planned. The respective locations of the two project entities are shown on the Project location m,lf1, following page. The review criteria denoted in the Growth Management Allotment Aprlication is basically, and most easily, structured for evalumion of a rroject proposed for development on a single 1,1I1d p,11'ce1. To facilitate n:;view emd evaluation of tliis project, which combines development on two land parcels, we have submitted each develop- ment com[Xlnent in a se[xnate section of this portfolio. Each of the two parcels proposed for development have been treated in- dividually as to their respective compliance with GMP criteria. The son s. Galena portion is discussed in the first PJrtion of the submission and the 925 Durant portion in the latter PJrtion. -~ .."'..... ,.,"",,~ ~~dr ~ I ~Ch.. ./.4 -- . G1:m jt:!ln.'.~ ~:...=- - - , :,~:tj "U'j t.:::.,., t..:~,l.l1 -. ,- , . 1 ~rt;~. Ut..; ;::.~:::::; t~j L~ ~- - j r..!.:1 r,l:::.::j r~;::;:l1 ';:4 ..~ 'i ~;t.H ,.;:::1 I~::;t:t: ~:;. ::-<< f1t :~ U::t;i [;::::-, r~'l~::B - J ~tld' f"l.'H .....::c. .....1~;) . 4U~I; ~.... tt........~ ,.;'t".. ,,-..- -. . 925 D t .~:j'H;::l. ~:~;2J~:;;::: ~'~' uran o tiH:U ~!!~ t~;;:;"" (clO:;:;: -', ProJ' 0Ct 'J [~1 f::;l~ II!,~~',\ ~~.;;;::~ _.~,H , ' , , !:-:::J..... t1r.o:....... ' 'I'li::;':: ;:::::1 <.A S:::;;:: =~ ' iI1~ln~1~ ~~f:;~ ~n~f] --~~--. ~~ i luiIlfll',t1J tiElib~:jH~'''I.=.._ '.,p'!,1;-J ~ . was ('11 - ) fJ- .:Tr. ;n:rrr~ Grn~::. ..(t:n. TT"?"'f"pn.: - -- .;.\ i~~!:~ ::::;::i f}::::2 .::~:::~:::::;;_:_. - - - ~ j,r.;t::';:,;:;::::;:IO:::":-:::l :~::::rlltt1t!hl;- . _ - JI ~\\[\~ ~i;mjf~):;~ ,i1~r' ,,' , . '~'~"'''''''' ~. ". ,,,l__tt!l!1tl~~-,.~,~J rjl1J_U1rlllll - ~ : r;, l?~::.~::~\.~~' "J::>c . --1,) . . 1 . '/....'....:,.'.1., . (. . . v" .' .' '.,: /.~.:....:.:,:-...~,i .. ;.>~;;.;;':q Y.;" ,- ';". ....'.,\, lor j,".T,>.\'V","-"Y' ~""".v,..,." 'Y.'~-"" J~' ; .J',.,./)(~.'\><: ..'y'" \,....,...'1 ~'\....,",.-,.-,,' r~......\"'."',~.'I' /.'/,.;-:....\ ,\..,X..',. ~.;,.,..../.; :::'~~~:.I j ... ~ . . . . . -\ .. 'v.. ~ . ^) -.-. , M . ..'). ., ,.,' '{1' ':}i:x'., :J<:.:'..' .;'\; >\\'.':.:.."> :-:.;':->.>:',") \''<,:,:.:'" -'/1 '-"-\::f.-lc-hO: /........,.~ ,./.....'.',~, ,/..../.....5 ",..., .'.'...~ Offi' ~j,J.)~ft-'iC.> ;,/....?~,-",/\,. .....-".",....-".^.-;.> :.-..~/.,...-"-"~ >~.'.', ',\' ~ _ )-{,'. "")::..-0 /1'/./'.'.'.\..) /~/,,-~,'~.'v"..-..:.. "(<\//..~.)<..<' t--.,>,'.'..,','\tl -~... 1" '" ...'. X>" ....') .....-,..,.. ",' '. ....' -..jl ( (J>-'l b7 ~:;~ ?:.;;.;~.::\$; ~<~~-::;::x:.~ (;:'~';:':;~~'i ~~ g"'P , ,,'"(' l'lr .... ",^2\.!'>.^/'y ! C 'l~""/7''''::''''I'''''' ~",'\.,\!\...v l ,>t~"'" ~ [, <~"\'.-"'\'j .....>',~'\'.'<.~ "",,.,,\.V ..",'\:\,'V","'."" '..:",'\ .'." ..".. \. ~ )( '.', " ..\..'\. ~'.'\' ','. .,1.>. ,', .. ','.11 :-<',\"\ \ ~I . ,.>.....\~ {...... .".:-.. .,......','.'.', ,:,"'.'."\V'; '...." f:\) '>;ly >:~~.;;:.<<~ ;:;,\<:;.~~..;j C:.:::':.\:~ <:::<..<:::rl'~~\: 11~""')r;J1),tm~l1 ~500 So G"'!c:na M"~" ,..,/,......",.........,'.,..,,"-..:'\'\ )\'J:.J'i '''x .\ . u.;;:; ,"',,:.' ,', (;:-;~':">:<1 ;:-:....:x .y.:: ::,<(;.:::'.'1: ';',\ 01.1.:: '::;::""'0 PrOj'''''ct ,,'^' , ~0:'~'\""'\"""""""I\"\ .... . ./..., ,-. ... ..... .','" ,'.' '.' >)...,.....,,:. ~>.\ .;...... ..:;..,'.;,... . ~1 _ ~L.."y\-~'1.^x':;.:>-; tq."'l~x:'\.\.,1 ;\,\,,,,-( .....r:.:..:-!..:::::lv4~'..:,4.- " ?\:c::.~.~ ~~~;-;"~~f'i<\.~':""'~'Jlri::\'-'<i:!i ~,,:. .....:~. 1:"::-::,;:':'''~ ~ {':',. ~,. i:\\.,-';::-<~'<.r:.:""\;">'l V\;~~~- l \.'\\,\ -:.;.:0-,.... ::~.'::'."':-::- :;":;;:-:'.. ~~.'~ y::.,",{! ifi;':;X"S;] ".;0... ':\ ))\;'~~ ~,:.::.: :'~a:.~,jJbn;;':"~'" :':- - ,;>:'\,;<.'. )<>"....\' ,,' 't<\-:';'.'" ,:'-.\ r "" ;" ...:....::........:.', :.,..n --f) 1 >',.v" y......... .~,1 I,,', ','.',-..:\ l < ',-;', 1'--"" ......: :....,'. ..... "'i . :"- - ,- 'Y;:~ :,.;.>.:<~-;;.;Il.(.>>>:.;:.;.~' f\:.'.t;::j \. Jr,!'\.' ....0 :.:.::::::.:.::::::'.:: .::::: f'':='--- ,..-== '=_:-:- ~>>-"lx;::s"",\V.IL-.,-I...c..,..', ,",.,', li'~)<' , ............ '. ...... ". ,~~?;~~ ~;~~,;;.~~~~{~:";0;i~$.~'Ji~\'~ ~:.t~~~:~!i!:..~.i~?fi;.:..::...}...::::.:.:~:- ~=-,-- <<.:~:..\.\; :<,',>,':.:..\,"l B RUBEY PARIV ;\2'1 '-.,\ 't ,:.'. '.. .. . .: . . . .: : ..... '.' ./ . &..\~~~~ ti~\i~~WAGNER PARK ~J \~ ~1\:':"':':'::-'::':':"':":'::"::<::':":':;:':':'I.,1;/' ~\:\,\/'x ,~I',~;\'\:",:::~a.--:'S}~\,.o;:dJ.iI< \"1 \ ,{ '1"0':::":.: .:-: ::::.".: '.:. : .... ,_ l'=-......T-~"tJ",..I;j."";:q5..Y...b. 'T" ,'.. .::::;:.:.....;:...:..... ,: .....; _ _,-..-... 4...t>ll ';J;' .. - ,.U'.~' "".'r". .", =- ::~:~';:Y::r'::\.:>~~:'.:>::..:;::;.t:.... . :' ...... .....-;,:PEf.'!>r:;D. J~' :'::::-::'~:~;j;.iY ?' ,) _- ;:. /:. .'?r. ~,':.',': :::: ~ ~.~ PROJECT LOCATION MAP ~ '" JtJ 400 I 800 (jJ2 r--1-.J o 200 ,"""-.. ,....' , "" "iiI' 500 S. Gnlena 925 Durant Combined Project Growth Management Plan Submission APPROV AL REQUEST The 1975 Aspen Employee Survey cleady demonstrated that 52% of the em ployces surveyed had household incomes less than $10,000 per year. This group is mninly comprised of the suppon employee, a significantly large ,1ml importnnt group to Aspen's economic structul'e. These employees Iwve been disenfranchised by the un- availability of adequate housing at a price they can afford. " An important aspect of this project is the focus on housing needs for the low income employee. Of the 29 total units proposed 45% (13 units) [Ire designed and designated to meet lower income needs. The merit of the low income housing provided by this project cannot be measured, only, as [I percentage of total units. Their more important value in meeting the low income need must consider th{u quality nnd size of stXlCe (form) is being provided at rental rates even lower than contemplclted by the Growth Man;Jgement guidelines. Applying the standnnl used by the Planning Office, i. e. 30% of gmss income spent on housing, this project crentes housing for 26 em- ployees (double occupancy per housing unit) with a salary of $4000 per year. The designated unit rent of $175 - $200 per month is significantly lower than can be justified by normal development economics. The unit distribution proposed for this project purposely creates employee housing remote from the free m:lrket units. The four lot site, in the I\M F zone, allows the development of larger studio units (425 s. f. ) with more open s[Jace amenity, thus a higher quality em- ployee product. Emher than being locnted supportive of a specific employer, the low-income units may, at this location, address the employee groups at large. " This project offers major and immediate relief for the employee housing deficit at a locntion within walking diswnce of all employ- ment, sh0pping, and recreational destinations. If :lpproved by GMP "V', construction of the low income housing will begin i,m111ediatcJy and prior to construction of any ree rn;J r .C! unItS;- W1ich will be phased voluntal)ly. . ...-- '....... 500 S. Galena 925 Durant Cambined Praject Growth Management Plan Submissian --. - ]n view af the urgent need far ]aw income housing such as this project will immediately provide, we urge that City Council autharize, far this project, the constructian of ilddition81 em- ployee units ilS permitted by Sectian 24-1O.]() of Orc!in:ll1ce 48. (Series af ]977). , , . /," ,., \ '" , r....'..::~ ::~~\ ;1 ~:~:.>., r(~: l~ """"l l,~:' ) " - - - - -..~: j -_/ '......~.. , iJ ..i (;2 T;~C~i"~?) :~: ;~) v: -.L ~~. . ~'-"'~ lJ t.L ~~li Ii ,,~ '<:'.. '.~ ~ ((:<'::1 '","-', \ \'~~;'/::-J ,- - "~<'0. "" f" ..-,:,., h~~ /,.p, 1: ~i 1--'( L:--' , \~ " l '~'-:J . ! \.:~~-:i~.>~".\ Ll~=-:3 t-b-,:;'~ ~ I :-:'~;j/?~::::-: ',:m ;'..~~:_-;.1~1 U ~': r1 1,,\ "~"V':"'~,lF-i'o ~,' '~""",'" !~'''';'''7>" ........... ,".' , ""l~ ;~r~ , ",~""',' t: t.,~, . 11 I.' ... .",~'~.. ... '~"""';:;' .'J ",_-;;.~.! ... ., '-0.,.;;" u ;-(10':::;"'1 -I:-"'-~r:' "";''':\~'.,t.' ~! . . '. , , ., ~, '';d ~ r; ., . ~, .::~ ~i t.'~ 500 S, Galena Project Growth Management Plan Submission Submitted to: Applicant: Architect: - - City of Aspen Planning Department 130 South Galena Street Aspen, Colorado Mr. Hans Cantrup P. O. I30x 388 Aspen, Colorado Copland flagman Yaw Ltd 210 South Galena Street Aspen, Colorado '. ,.... 1,.", - ,-", , ~'~l J:S I ~i' i ..1 , ~~ I' -i:J ::}' I (})i ('j" I a:, i C! ! fi) i "t\ l ", I ...... I tel I ::1 , i , ) ..- ( 1 , I I i ! / ,.... '''' .. /" 500 S. C<llenn Project, Crowth Mnnngement Plnn Submission lNTHODUCTORY 1. Project Name: 2. Location: 3. Pn rcel Size: 4. Current Zoning District: S. Zoning which Applicntion is filed under: " 6. Maximum l3uildout under Current Zoning: 7. Total Number of Units Proposed and Bedroom Mix: 8. Size of Units: , 9. Price Range for Sale or Rent: / '" ~,-.II 500 S. Calena Project 500 South Cnlena Street City of Aspen 21,600 Sq. Ft. L-2 Zone, City of Aspen (RMF permitted use) L-2 Zone using J\MF Option 21 studio units or 16 one-bedroom units and 1 studio unit 17 units toni!, comprised of (16) one-bedroom free market units nnd (1) stud io employee unit (a) one-bedroom free mnrket units @ 1000-1200 s. f. ench (b) studio employee unit @ 600 s. f. (a) one-bedroom condominium units sold nt current market price (b) studio employee unit (mannger) rented at $]75 per month .......... "'"" ....,I "'" 500 S. Galena Project Growth Management Plan Submission 10, Program Na rrativc: The site is planned to maximize open space, landscap,,"'Cl at the public corner of the parcel and to pennit the functional organi- zation of two basic building groups comprised of (16) free market units, in a massing configuration compatible with neighborhood scale and pedestri:m movement. Consistant with open space objectives the majority of required parking is designed for a subgradc location. This additionally permits weather free movement fWIl1 vehicle to individual unit. Buildings arc designed in a two level stacked configuration with inclividualunit plans canted :It 300 to permit solar and view orientation up the mountain and to further reduce the massing by the staggered building form. The a rchitceture of the buildings is characterized by sloped roofs stepped in relation to grade change, the use of native stone, cedar siding, exposed wood beam exterior clements and projecting balcony eleme11ls. The site will be completely 1,ll1dscaped to create privacy and to cre8te a corner green slx1Ce rc18ting to pedestri:lI1 mc)yement. The floor area r8tio permitted by zoning for this project is FAR 1:101', 21,600 s. f. of building development. As designed, the total project uses approximately 18,500 s. f., or 85% of the allov..ed FAR. 11. Description of Surrounlling Zoning and Land Uses As shown on the Vicinity M:lp, Galena Street in the L-2 zone. the project is located at 500 South Surrounding zoning is L-2. Surrounding lanel uses arc ::1 mix of lodges, commerciul facilities, multi -family and single -family units. Immediately sUlTounding complexes are the Tippler Inn & Lodge, Continental Inn, Alpcnblick Inn, ancl DU1'8llt Condominiums. r~-,,,,:"'''''''-'''''''''~-''''''-~'nA'' X~'-7<""""--'-"""-"";Y~"".'-'~ .~ ~-:>- --"'.'-'-~-"~T"'"____'.___"-'~~;~.~r' ,,'- ,..."..~~....~.".,-..--~",:--,-.,..,. r~---'--_." _"~:';:"--'L_._;._ _ _"",,","---.,_~ -_....;........":............"...~~ '..---';-"-,-~",,,-<~,, '~,:"';"',',,,,,,,",,.~..:-',,.,,..:..~...:...-,,,,....;....'~ :....""~,--......-..."...~-,- I J ~IIC'~I\.l~Y 8l(MAlhl ?T.-----(~. EXDT1\~!7 MAUS--- l UFT I.A--~ 1 1 l J 1 j 1 GALfl-l^. STREEI ---MILL '5T'nET , ~~ W1ME11.IAL COT ~ WlI1ER::W. UT.hf. o u;r&E l Uill] K[5<PcfITW.-/?,LOC(jt ~~ F,KK!F1JeUC Vicinity Map ~ o XX) .00 1 000 ~ ~~-- ;~--~' -....~'...-~-c<.,^.,-,-~..':;:~~;J".~ "', --->"'r~~"1"';",",?""'~-~~:."""",,~:~___,,:",,~, "':~";:-''''''~''~'''''''~'''_',,- ,., '-".:~,' ".l;'.' .rl, .,,;: l:,'I-;';-, "",""'.' "/\i, i:_"_' _"~',_,,,",,_C,,"~._;,._j...,'h , .........._-"'-'<..._.+._,-.."'-_.""-.~.<.. ..~.-'-~ .-..~ .."',,",,-; ........, .............,._..,.~_.'"'-.,."..- ............ .'-~~~;,.:::.:..~~~'" .~_,,~i "'''7:t',rr'!''''''-:''''~':''~'''''''--''''~'- "'<"~'~~""'."""'''--''7 -",..."",-.".,..,:.~... ~.-,,,,,,- -'-""''''''~''~-,~:''''''~''~-~-'<''.'~'T'''.,.~~~,.,-,,,-.,-:-._; ". ,.~............,......--...... . ",-" .', ,..--""'.. " ..' -- :"-""'" "." . --. . " .j:.::~~~;;;......"::,;,,~,,"_~,~,,.:.......:.._....~~~~~,d.i..~..;.;...;.;.>>:..~:._'i.!.:.-ii..~:"...J....;,.'i...-. ~;..",. .......;...:..~....~:.J.:..t.L...;:.~t.;:_....:...l.4"r.....'L..~;..:,2...... ~-d"';;.lii......._i---'~._.:_.:.,...: ~ fJ..'O( 5J^11OH ~ ,ruPNlT AVm'E~L__83__..J I L-____~_,__!~ WJfl' <<"- ~""'~:!I~~!I':WU' '~1~"'&" ,......-lI~~ =a) ! i~ _ I ,\~UU"-'~IIIGlll' 't ',. '.=_ -- - \-"" ."Il ' .0;...." I r ' I,~# '1 ~.."''',... m""''''~~~'''..~~'''''''''~'' III (_' /' , ,.,.".. UT1l..C f-eLL ~'~~r-~1~f ......~. ""en D If ""1= " j l I ~,,- ,-: - II I (f ~~ " '. ,"'" It,' ':opj"1~ &.\V ; .. ii' <> "', "-,- 'Ill 8 ~~ g.c Tlm~l>1~ j 1 1 , 1 ALf'E~ rua,-- I 1 1 rDmffiHU7 ILX " STEEl' 5U<'CS r;urniT = , / 11 Site Context r'2'~ f~;-E~-"",-',"~~c'~"\~-JC<:1=-''''~'l~'''''''~''''l':;':'z-.."".,;,:~"""",~"""~.'-~:f""-"'"".~-.. 1'"......,.... _~.....?'""'''''!:'''~,.....,~',..",._lO'''....,.~ 'l .',;! '.!."JT'~; ,.,' ::'i,:<,, " , ',; ,.', ,.....~:_... ._..",.:/'":"..;,._.;,.~~..;.,;;~:~~,;,,,,~,~~,,,,,,,,,,v&..,<~L~';;';~.....__ ,_.' ~ .";'.:..;. ~",,,",~...~.;...-ii~ _~c_. .. _~__ @ - ~ r-"--~....,.~"... .:',' " ", -, -..._<:_,_ ,.._'....."'"'~""._ ...-;>__ ..'~_~...;'~_"'..,....._.~.... ,...~- ._.:~...,.n"'" _~--,,~ ~~..'.--:_';'.....,........u ".,~.__.""".__~--::""'.".,." '-, .....J' ,_. I I i I I ,J I !~:".,,"' ...;~~..........._--'--'''"~.:~__,'~;.:..i.;;,.&~................___".,~;..;....::,_ t I , NORTH OF N[lL .-....~'~J-..~ --~'~~'~.,.~~' _.r: 1 010' :,' 1,1 :. u ...J :,./ L.. _.~._.____.~L_ ,. -" ',' -':.~J_,~"''''''"''''~'''--''''''''' 1 ---I , , _..___________----------- I \ 1 I J I ~ Lr- _.__ l~J-U~l~~"~/' ~;/~~~:;l~,~. ./' .>-'.~" i'I -If :\) , / ~///-?~,,). J / __'f" I ~_I /y..';{" '\~ ,J 'I'! I ..-< ,. - ~ 1" ,,'....'~ -v' : 11 I ('\,;-' -(,.,\ r) ; ~ i' I ~ ft"-:;?'" ~" \ ~ - -, :"'1 . i ,. f;-!/0fC'..>c:0i/1\'/'j =,~ 1 I ' "t/, _ '- ~ _/i III . ! ! ~;;{Xi -= r;:)1~lr l~-- .-, - '. I \:1I't,;','i ,,',.,'~~' i .____-' I "i"-.' .\.:.J.' ~j-/~" --..,.; I 1 .t. . ,'<J.__...,_. " '--': \ ";~. '::;;'-' i ' : ~(;'-. :"\, -- l.:j /''''-.~''I-- ; 1 .~ ?~~I~~;} -r,-', ;~/ fZU'f: j' I "",' " " -;' 'h ' .' ""," " : I- ~.~ ~.>.t~,.1',::::~,',jf();,j,\~~ :,~..~~,<>~..__ ,....... .f I ~ .~ ')'1 \{ .,_'''_'1-. ,_",~,'"~",-,,,~":-"...-l , ... I ~ >~~.,,~~'>>'~T--'--'~'~~'-':;:; :, : ~~ ~J~fV):rj"", I~J0IJ,{ ~ t:!; ~~;'.;</~/f."'J~N-4'.Jf ~;> 0 ..J f~\\\l";;:h /\.: y,/ . '" r~,: ":I,' \\",,>,,;..;,,,>:f,""v' ",>-'i.:\<..{1 ' o ." "1\\ ;2-\"\\J'.\\\\,...' ...,.",,~...<:, .."/ ~ vi 't'< ~";:}.~(..,,, \'...\:~'I-\~,~~\>-~,:.\,~/,.,.\(;.../ ., :':',:1;1' ' 0 Vi '.1 '-~L, -I J , , , i i , , EJ, , , l, I I li J ,j I DEAN AVENUE COIHINENTAL INH '~ ~ (-] - _r-;-1 --L ~ , i I' 11 11 II I; " I ~ ! Ii !I ti n I: Il I j 1 II , , ! ~ 1 .! :1 '. .~ / ] SITE PLAN (.:.:;) ~;;7 - r-~- I o 10 20 40 60 I -~\ j i ,-- 1'\ \ ,..,---.r.......-:<'" ..............--,.-, -""""'~. ~"l'"~.-.-.,--~.....-- -", .r...........,.......,~__..'..~.....--.<<-""7""""~ ___->(.""-~.---;:--"""".....~..T"'::--=-.....---,___ ~ l " . ' , .. .. . ..._.~...........-----.._ ""'"...._...__._"'_~......,_w__.....-...~~ .j._.,-"--'--,,~_.,.'"-....=.~~............._~ '.~' '/,'..'; 1 ~ j ~.i:_.:.k~,;.~:::...",-:j , - -) . -_....~--~--_.~ _~.:~ i~._ ..- ,"",,"'" RAMP TO PARKING BELOW \ ...- .....- ...- .....- / / / / / r / / '~/ / / I.. I I I I I I I I :...._---, .....___1 I I , / l -/ I I ( I , 1 I I I I I I I 1 l- I IJ.J I UJ I cx: I l- I CJ) 1- <t Z LU ..J <l: (;} cri ~- <^' Unit Plan 500 S. GALENA ST. PROJECT ~~ o 10 20 40 80 I I , -"""^,, ./' , , '\ " /..~ - -~, recycling_ Gli~enter " '-'-7 ',) , / " y' ''y' '\,/ I' \ '>/ J)-....... ,)' ,~........ y: , , I ~------ , , i I )i~~--' I '~ l~r~derground :/ Parking , I' ---~.__._" (.: 10 Cars ./, ,---- ,I SUrfacc- , I --.-. Parki ng i - II', 7~,---_ Cars \ ---- ~ ~ " fl V) \) '/ " v., . ~ ., I Q I 3 ,~ J 1 :~ IJ !'j ~---~ .- W LU a: I- (f) <3: 2:: UJ -! <t <:) , elevator // / \ , \l; ,/ , " 1 ' 1 \' " \, , -~ / I , . '" >; "Ii) ~l-j C i\I // / / \ ./ '-_./ Underground Parking Plan 500 S.GALENA ST. PROJECT A ~!V r-\.-.J~~~ o 10 20 40 80 '~':;-':~"'-;""""""~~"'''''''':;"''._''~'=-'''~''"''''':''''-"'''''''''''- ,,~,_v"""""_i_':_":',,~'''''''''''''''~_'''''~''':'':':'''''';'-'''''''''''';-C'7~'?'''~'t'''''--'\-'''--''''',;,:,~,....v ~.~.'r--' .......,-"" .,~C~. ""~-~~~'.:::~.,~~';~\l.'~"~~'_:_="c'~"C"C_- " d_\ '. l.FL~~ ;'e Is, :r; ~~~)~~~~ '. ''1",'' ?,"!""JH",-:-;"<",, L :' 0 .. ". \..- ~. 'l. . 1 f~ ' I' -~; 1.~,Ji? _1.~I,t\l'h-~ 'l-r",'J.t3/IJ r ", ,,1,',..[,. li-", ; . t:' .~."~"'\ .t".' ... ' '1'.- p"- lie[ t'" " ~,u_' lj :i ]',1 ~~ ,-,..\11-6 '~,.. ~._'~~ -~-~ i.; \:O~'.O:F),.tt,.~~,,::,p:<~ t f'r..."", ,,' '- \'/':r-' <':~' ~> .I I"r '''''''' -'~,itt\ .>g ~b'~"'\"7~\""""'f.i , ; lL../J:!oI':?f'.'; ':"3:t \'.~ . ~ '!i~ ':" "..~.., 5:~ i . I 1'" i:1 ,~. ._,~~ : l,,~... .\,-; __ '; ~: ~ r...... j'\:Li ,':./' '~", I b; ~';~:I "il~;". JH I j! ii;-i .'..)~ ) -n'} '~ 'c h ,/,' I/c''''t..t ::~. , '\ g' t:l .,' - ~.' 1l7'I"'ii\r1i~','"'I.j Jt1" I r:'H Ili~11*1TJ~ ![l]~" r'j "~I"t'~~-~l~~,;. ~ . .1, _:' -'1.1 ..I ,,: .,J~ ~- i \ --i " ,~ . i r J ~'~c.=-- \ '1 /'~ \ ,i 1 o r ~ -~ "-..~ ~= ~ .~, ~ ~i"'l}.THidOU-d I- UJ III a: r' (j) <( Z UJ ...J <( (;J I ,1 11 II '\ L 1\ \1 !\ lJ j1 I) 'I I- '1 II I. 11 " L 11 \1 " I' il [I II \1 Ii I' il ,. u (I " II Ii f I ~1 [1 [I '1 :r: I- :J o (j) "' ~ o 0: u. z o f= (;) UJ (j) '-- z o ~ > UJ ...J UJ , " J, ARCH ITECTURAL J \~ ~ _:. 0 ~ 10 20 40 I ~ I .J H t...-....~r<'"~.,-,__"~..!';7-:,.,.'__:'r:-:~.;1".-:-,;ry,..----. "'..~.~..:::_' :~..~ ,> ~,~,,_. ....,._.. ~...,............",..,,- .......~~,..,'~.""....,.."""~.. --- .J " "",',,'_;' :r:,,<,c,' .... H,<".,: ,...' '.,,"" '7'-"-'''--1 . '..~ " '. - - -.'"'' .'. '.~. .... ~ ,~~__< ".,__'"..,~~:._".~ :..<~.-:., ~,,,,_~,,~'>.'~~'<~"'~:___"'~__."ii,,,,",~,.......,<.._~_J . "... .......'.... /-...." ~" '. .J'. . "" ~'.-.... '-~ '" j 500 S. Galena Project Growth Mcuwgement Plan Submission PUBLIC SElWICES (aa) Water System The eV[lluation is the capacity of the public warer system to pm- vide for the needs of the proposed development without treatment plJnt or other facility upgrading beyond those provided by the develope I:. The project water demand is directly related to the fixture unit count, consisting of 300 F. U., which converts to 80 G1'I\1 maxi- mum probable current ASI IHE guide stilndards. The 6" C. I. P. water main located in Galena Street, 8djacent to the pl'Oject site, will provide good flow and pressu re to the project development. A project review by 1\11'. James i\1arkalunus indicates that no fore- seeable deficiencies exist with reg,1 I'd to In'oviding water service at adequate pressure levels ,md no substantivc impact on the tn~8t- ment plant, which is currently Ulili/,ed at approxim8tely 75% e8pacity, will result from the project development. l\efcrence A. Site Context Map, this section B. Project review letter from M r. James]. M81'k8lunus, Aspen Willer Depanllll:nt, this section (bb) Sewer System The evalu,ltion is the capacity of the publ ic se\V8ge dis[Xlsal system to serve the proposed development without system e.xtensions and withou~ tre8tment plan Up2;l'<lding, The project site is served by an existing 8" sewer line in serviceable condition extending up S. Galena Street and located directly adjacent to the project site. "..... '"...... /" 500 S. Galena Project Growth Management Plan Submission Applying the Colorado Swte Department of Health standard of IOO/gal. /day /person to p1'oject occupancy sl<lndards of 1. 5 per- sons pcr one-bedroom unit and I. 2S persons pcr studio unit, lhe total project would gcner~lte only 2600 gallons per day. This would add less than ]/7 of one percent to the pLlnt C<l[XlCity, thus is well within the service capa bility of the present cap<lcity. A preliminary project ['eview by M1'. lIeiko Kuhn indicates that no foreseea ble deficiencies exist with rcga rd to provicling sewage service to this project <lnd no subsl<lntive imp'1Ct on the treatment pl<lnt, which is curremly utilized at approximately 75% c<lp<lcily, will result from this project development. Reference A. Site COI1l,-'xt Map, this section B. Project review letter fmm 1\11'. Beiko Kuhn, District Manager, Aspen Sanitation Dis[>'ict, this section (cc) Stonn Drainage The evaluation is the capacity of dra inage facil itic;s to adequately dis[nsc of surface runoff without public drainage system expansion. The drain'lge control system for this project will collect and retain all sile runoff and interrupted subsurface flow with on-site drainage facilities, The project shall have a seric.s of dry wells ane! retention wells sufficiently sized to, retain and disperse site su dace ane! roof waler runoff. Consistant with ,;ullldard engineering pr<lctice, the e!rywe"tls will have overflow outlets extending to S. Galenn Street. A pl<lnted diversion berm will Ix; created at the uphill side of the project to diven excessive surface drainage away from building devclopn1Cnt thM would result from :lL)J]clI:maJ precipitation. Reference A. Site Plan; Physical Design and Program section . ......, ...." 500 S, (;;lJcn:l Project Growth Miln:igemcnt Plan Submission (dd) 1"i re ProtccLion The evaluation is the ability of the Fire Dep'lrtment to provide fire response to the project ilceoniing to the established response sUlnclanls. The project site is located :lpproximately 1,,00 L. F. (4 city blocks) from tile fire st'lrion and can expect Cl m:iximulll resrx>Ilse rime of minUles from alert siren to equipment arrival at sire fire location. Tile project devcluPllwnr will provide an on - site fi re hyd rant which, in ,H1LlHjon to serving thif' project, will upgrade the protection system for the immediate lwighborilood. The building development will be :idelitioni1l1y protected by a elry standpipe system, completely sprinklcrcc! parking garage and ionic sllloke detcction in inc1i\'idu:il units. ^ project review by 1\1 r. Willard Clapper indicated no forescea,ble defici encies exi sl with regard to fj rc protection, l1.cferellce: ^. Projecr Vicinity Map, this section B. Site Plan, Physical Desitin ilncl Program section C. Project review letter by Mr. Willard C. Clapper, Chief,i\spen Volunteer Fire Department (ee) Pax.!:}ng Desigt.l , The evaluation is the design of requi red parking with respect to visual impact, exposed paving, cOI1\'cnience and safety. The majority of tlIe required clll-site parking (1 ,;pacc per unit =0 ]7 spaces) has bcenlocated in an undcrgroundlxuking stnlcrure belcJ\'! the resiclcntiill units. The p:lrking structure ,\'i11 provide for 10 of the rcqui red spaces and the remaining 7 spaces will be provided ;15 surface pClrking SC1'ecned by landscaped earth berms. ^ll parking has illlmedi<1te and level pedestrian decess to the pro- ject c1ev'llor as well as ilecess stair,., .- '-" " eo' .500 S. Calcna Pruject Growth Mnnagement Plan Subm i ssion - Reference A. Site l'lilll; Physical Design and Program Section B. Parking Plan; 111ysical Design and Program Section (ff) Homls -111C evaluation is the cnpacity of existing roads to service project generated tJ:affic without substantiolly overlooding or altering existing traffic patterns. As shown on the Site Context Dri1\l'ing, thi s seclion, the pro- ject is located on Galenn Strect npproximatcly one block south of Durant A venue. Examination of the tr:lffic impact of thc project is primorily based on work generated by tlw Uiv'tTJ\ t::nnsportation study and on recent conversations with M 1'. Steve Lockwood, Alan M. Voorhees 8; ;\ssoc., Inc., tr:lf[ic consultant for the UIv'lTA stuely. The table below presents the trip type and trip frequencies per day per unit for a project unit as estimatecl by M1'. Lockwood. The 6.5 trips per unit is less than the 10.0 trips per unit for a typical residentiill unit, because the project consists of one- bedroolll units generating less people than larger apartment or condominium units. Total trips arc estimated between automobile and non-alllomobile trips. Trip Type Estimatcd (}nc-W8Y Trips Estimated Non-Automobile Trip Perccntoge Estimated Non- Automobile Tri P, Skiing/ Recrcation* , .75 60% Work 2.00 7507 /0 Shopping and Entcrtainmcnt 1. 2S 75% Personol Business 1. 00 SO% Other 1. SO 25% 6.50 60% average .5 1.S .9 . S .4 3.8 .-- " '--,/ , ( \,~ '500 S. Gnlcna Project Growth Mnnagcment Plan Submission *The ()()% non-automobile aVer[lge for recreation trips assumes approximatey 75%-80% of ski trips are non-automobile but only 50-557<', of summer recreation trips ilrc non-automobile. Due to the project's immediately convenient locarion to downtown Aspen, Lirtle Nell Lift and Rubey Park ski buses, it is estimated a high percentnge (60% to 75%) of skiing, work, shopping and entenninment trips will be non-auLomobiJe trips. , As shown, [Xltentially 60% of the total projected trips per unit will be non-mIt.omobile tl'ips. The estimated 2.8 automobile onc-way trips per uay arc equivalent to a resident's using his car on iln averilgc of ilpproximarcly one time [X;r day. The walking and public translX)rtation convenience of the project's location plus the project's low resident population results in minimal trilffic imp:lct cl'eated by the project. Current detail traffic counts arc not ilvailablc for the area to quantitatively estimate traffic imjxlCL F.derence: A. Site Context Map, this section " ' (gg) Energy The evaluation is ability of the project, its slxlCCS and users, to maximize the conservation of energy. Consistant with the solar,geography of the site, all project con- struction will be designee! and built to m8ximize solar utilization ane! to minimize heat Joss, thus reducing the demand placed on the fcissil fuel resource for space heating. The following techniques will be implemented in this project. Insulation Significantly exceeding regulatory thermal standards, exterior walls will be insulmed to 11.=26 to 28 min. ; roof composites to 1\=42; floor composite to 1<.=20, foundation perimeters to E=14. ,...... '-' :) ,I 500 S. Galena Project Growrh Management Plan Submission Architectural Architectural design configures buildings to optimize thermal characteristics of the projeCT. Exterior wall exposure is mini- mized by staggered unit concept (common wall), and by vertical space oq~anization (minimum ratio of exterior surfaces per sq. ft. of occupied space). All buildings arc oriented with highest use interior spaces to the south to achieve view while maximizing passive solor heating potential. Glazed openings on non-south exposures will be limited to Uniform I3uilding Code minimums (to comply with ventilation re- quirements). Opening surround details will be required to mini- mize heat loss due to infiltrotion. Partial flat roof surfaces 0 re designel! for all units to retain the additional im;ul:Jtion value of snowfall layers. Devices Consistant wi.th solar geography of site, solar collectors will be urilizec1 for domestic hot water healing. Electric energy will be designated for primary space heating to reduce fossil fuel demand. (approximately 50% of electric power' used in Asp~n area is hydro- generated). l\utomaLic thermostuts will be specified to control night time space tempenttllres. Fire place desisn will use double damper control, exterior combustion air, glazc'd fire opening, and heat return ducting. ] lumidification will be used to reduce temperature rcquired to achieve equal comfort levels. , Reference: A. Architectural Drawings; Physical Design and Program Section ,......,.......-,.~~.~......,._ ~_, ~.-<'\'...,.'7.:-....... "~<""'_';-.-: ',. ...-.,...,.".-... ....,"._~..~._."..A~"""-.'l-- ~,-,...,.~:-..-,:->. r__....;'" "~,_>:<:"",,..,~:-..-.C':>" _-:""'''':--:--rr.-"r~~''''.''.Jc' r" --,~ ,-.., ,'-..- ,__..e, t . _ '..i.,_'-o.--._~..'_......_.~_..;, .,-"~.,,_: , , ~;","",,-."""''''_'' V._"_"n_'.C~...__"# _;. ......~..~.._...;..._.'- ""--'" ~ ...Ji,~;;"......~~"...~ ~._"A'_~''''' ..~'--._. _...... i FIRE 5fAflON /;';ClICE 5f,,1'1<.+1 H1C'HWWBl.!t1AJl-J sr.--"r:;.....~;, I Y.":i..""'-.,._;.~~.,,~.:n.~':o../ti-t"TZ'..z:.-:'lo~~' ". I)~ .'''. .. '. tV?> '.'\ y..~o.'." ") ....,., "..., j:';..>:ii L fr, f; ~ g~~:~>~ fi "." '-",-, ",'" ,,'" ,"'"...' "" -- -I l"",~::,., ....: t '.~. ''''~ ::."'. ',^. ,:(:' I . "/. ~'... .-, , ~ . . ~ !;'./'.~...~'.~:f ;',:j'..~,;,~ "()..\'....v~' __ ;j E'lf.)TI~o- t1,\LL'";.------~-~- ~.U-\.L;>J:;). V ."'\-y--o<.l '".':"; ':'.,,~ l\"..,......, '\. ~ - ~ ~ Us.. '-{'I:'" ,.' ~"."~,,.;.~;:......,,;:~ I, \-.lA&NIJ: flf.K- I' 'r- ~ ~ '\ ...., .'?' '~. " \( ;".. ~'.~ I-J ~ ;:$ ~ ! ~. Cl . ?\,::.. ..., I" >> I )1 1.-:;' ~'-'-'-J .{,.,......., ~,",.v^.., _ __~\~~~~~ 1 n~f.T"';.K 5V-T1[.t,j----~~ ,(~~~~J".';"""7-,..,.~?t.\'~.,'\.::~ ;-:::v.":'~:~ ;:-T~"/"'.'.,p' ---. I j;i"''' ,', I,i.~<., :JQ' . .'~ '-..^ ',' ;....... . -: U ' ~"';~-,~), ~IT~:';~ '''ri'' ';'~:'. ~ ~ ..~, <. ':: ~...>: ~>.') 1 t~, '1/:.- ':.~~'J~.\c,._~_ JL:=r_~:....'- ~~~_~~(~_~__tlJl"J.ur ME.t-LlE. ~l M wJre ~_._~~. --;;~/l,\~ -r:-:;;-,1-;:~---"--'--" I \'"' /~;.. J"l:" ~'I 'i, <<'ifIR{"2P;~"'f~'::C'0~ "~~ aw-<;:~,"6itl~.\}t"'l-c"'AR, ,~ -- --~-L{1\'....E ~fLL lire! ~"1~o5 I. 'K. J /-, f~ ~'\"'-. '" : ~/~ ..ti;: '~"'\s, I1i1WWL ""'? LWc'-~-.' :-:71' ,,' 1 .' >; 11: u"l ,',' 'I ' I"'" ,,8, '3 %/1 1 t~~"'I";.:..'l .~~<{:q~:~,~~ (.J ll,i un I.A-----=~\~:~'If~J[tl:ii)J(~' ..;------0= 1 \ ~ 11~~r \ .--:--~----rmJE.:T :.m. '1 {!JJY~ - - .-------GALfW. Sir:fET I \ ----- -----I1ILL 5i>2ET 1 .., 1 1 '1 ~ 1 I ! Kcc{:;ffITVL.I5>'li'C0E. 1111 Wi:! "'/0= ~~ .', l Vicinity Map o,.x> "'0 ~ " .t~ ~..c-f<"'T:--:"l"~--:rc." ~,- .".~ ~_:""~''''''''.'';'.'r'''''''''."''.,::,,,:.:-.''.'''''<-,,:,".-::-'''':'':'''''.. "'-""-"~"": . :.;.c:'...,........ -:'...,.:.....-.~-,-,-....,.,.~--.,~-~~';::--.---...~~'~~.':""""'---",.......~.'-:~'-. ~, , f-' >. 1- I " !'- H f I , i L ~ ;' I rrD:T\:':: D C.\T( Tr'..J.JL , ; . f- ! i ; I 1. r:>\\',~-~ r~~~ ~ L'J mnn W1!1rrLIAL c.cr-E CLl1nf:1W>L UX.(;[ ,LC%t l ~31 L~... _""_."_:'_,,,~._.~.~~,, ,~~~-,.,.~~~._~. --".~". ',; "'I,..~.,'j~' ,.~......."'''';'' __....~_~ ~~._.;._.~,.-.<."""'-i..~;;.....;.:.:...._:.;,...~_-._ " r.".,...'-._.,~-,..._-.,.,.,.__.."'" -.'" _..,"-,....:..,........ - .. t,~,",,-~,.~ ...n....... ,_" .----...'....,....k:,~___.......".._~.,.".....~.:..__,_._.._ ..;..,....,,,...~,. ..- ......_.~.,_ i I . "~"'~_"_""""""""_"', '",,~. ~_''''''''''''I"''-,-'""",":-.~..,__.~,.,~",_..,..,,"T"'''_ ,." ......_. _._.-" ~,_,,__;, ,.~ ..>. .,..........>..........:....-'<. ;-.......:. <_4....'""'.....;.,'.;..,~,;.....:.:....-~~;..., ._......". i t.. I' /' / I I j I I 'j I1ffYf}J:Y, SlA11"'....--,.,....-~ !1 !.liPNIT AiE!-l.lc'" -J~._:~-=-;,'r~'.l:~.::--=_..) JIl:., ,.._-.:-,-~----=--J L'L'~, = I (~-","~""""C"'_"_':l':O==.;;:;a(..~;t;O~::='::""""",;,g.~"""(__",=.u::.::.:_=~-'-_==..~~",,,,,,~) ':jl HIU'AHr "--'-''''JI> ~G:l1fr3{\1-='=lJ'II'!I'I:i ",,;;~~~:;O-"'=J"- (~'€'~;~J ;:u;~ [ L . I~ "..,...______,.___,_,..~.c .."..~ ~ --~---~----._----.- I '~\~~7,lla"..g,\; --/.1 I \'\'~~ __,~ "'~I - '-..:,j. j {tl'r,J!j~fll'/1.~ ~~:I"':;..ta~:f5;~~~f'r~~uu~lr'a:'!t.'1111 f I ~> "~#I I -- '. ~~.~.z..lI>==~J~1 ! ;-.' ~"~ II""" limE ICElL !'''J i f"RlWO.W CflYWL,- t.._,_ i IP,,~;I'" ",,,<) ( jl \ ~/ _ _ J ,"- ", , ~. r- -,-'- '\.. 'I;' [J ri' /j A,. ~:::;;;:n,.,. '" '. II 'If )"11 li I .. '" ", - - --. 1 1 neE I~" ~--= I Iii ~1/1 r>~~~1 ~s~-~' -----~1lr1li LO.R l'f7-":'j r~''':~~ /'111 (;2 j ,dO .,':./ ~ AUrJl E{JeK }j,:'li..lu' I.{ ~".,~~ ~ ...... / ~ "- L~~N-i'l 1/,,1 0 0 ,~ .- -.--"nE~ 9,[n~, I ~- ,L 11---,1 '~ J ~nH% l/Y~ ------- "--"",,,,111) 8- ~______n,_~_ -PJ>~Hf cmw; I Er 1 l '1 j , I " I, I I' I.' i Ii I I. i: i , t' i. , ): I' i ;; , ;' i.. r; i i. ~ i; , i. i". ,. " i; i" i",,' ~' .. , , io I, , ~ , I; " " i! H i1 ~ ; H " t", !! n ~ : ;..; 1 1 '.. ii H ii : L Site Context r--"._ ______J o 20'J 400 flO') r.::~) \~.//' Ii i! ri !: ....-..! , , .~ -""" '~""~""""'c:"-~'f' .-,.,..... .'" -"'--''!7'"': -'-'~""'-"-' ~.-""....,' "",-"~""""'-.-.~ -",,- ......n,.",..- ',F',"7"<'-'-~' '. --"':~':."'-"':--.........~,~.-~-,..,..-~-~ ..,.....,....,..., ....,""'.... :'-7;> ',;'1;;: "':.<:, "'\!~<. :_,',,~. -D', ,', - ,:,~'~-~:;':! . L'~",__..._..'..~'..'n_..c,....~,_..,,_,~ .. ',_,~.: ,.,...~<~,_"".'....",_,~ '..".......... c. ..;.....-....;..:.'cc.. .._ ...._. J .-."............, ,:--"......,..:.~.~..'",:;.- ,.:~-.:~~:.'.."-~:>~.;,.,, ..'...;-. ..~ Asr'"N SANITATION DIST"""CT ~. . ' r. o. Bo:1. ,~lK Tell,. 925~3hOl ^SI~Ei,. COLORADO HHd 1 January 30, 1978 Mr. Larry YaIV Copland Hagman Yaw Ltd P. O. Box 2736 Aspen, Color"do 81611 RE: PROPOSED SOD SOUTH GALENA PROJECT Dear /1". Val": I have revicIVed the above referenc~d project with regard to the quality of se,"er service to the proposed bui Iding development. I understand the project to consist of (16) one-bedroom condominium units and (1) studio employee unit. The project is pl-psently served by an 811 sewer 1 irle in serviceable con- dition, extending up South Galena Street adjacent to the projcct site, The present sewer plant capacity is 2.0 million gallons per day (M.G.D.), ,"hich is presently util ized at approxomately 1,569 M.G.D" or 75% of capacity. A new addition to the plant in 1980 wi 11 increase plant capa- ci ty by an addi tional 1.0 M.G.D. Applying the Colorado State Department of Health standard of 100 gall dayl person to project occup.Jncy Slt1nJarcls of 1.5 persons per one-bedroom uni t and 1.25 persons per studio unit, the total project would generate less than 2600 gallons per day. Thi sIVould add less than 1/7 of one percent to the uti lilation of present cdpacity. Due to the uncertainty of the total number of proposed units and their locations under the GrO\./th ~~C1rV19Cl1lcnt Plan, the total impact of the approved units on the collection sewer lines can not be evaluated until such time as the informi:1tion for all projects under the Grov/th Management Plan is available. There presently exists sufficient plant capacity to treat the proposed proj ect, If there are any questions, please contact this office. Very truly yours, ,.J<--L !~- He i ko Kuhn District Manager, Aspen Sanitation District . ~'- I i I I I I I I ; I 4 I ; I I , I I j i 1 , I 1 i I I I \ \ \, ~-., "', I I (n 1 01 (:ii rD' i ,_. I "Tl I tn' i () I .,," , I ::;~: 1 (ii'l i" I ." no 1 r ,oj I' 1..<1. (,) ..') , i :,L~-' t" ,; I'l (;) , / ,..~, .-r" ,",,'/ 500 S. Cakna Project Growth Management Pl:ln Subm i ssion SOCIAL FACILITIES AND SI.:lWICES (aa) !,ubl ic Tr,msIX)rL~lt.!on The cV:lluation is the ability of the project to be serviced by public transponotiOll. As shown on the Vicinity Map, this section, the pl'ojecr is loc:lted 350 feet from the lAn'ant Avenue bus route and the Rubey Park Transir Stenion. These distances equare to a l} minute walking distEll1ce, thus casily accessible. Reference A, Project Vieiniry Map; lhi~; secrion B. Site Plan; Physical Design ,md Program Section (bb) Pol ice Prorection The evaluarion is the ability of the Police Depanmenr to pro"ic]c normal protection services to the project wirli current personnel and equi pmcnl. Conversations with Aspen Pol ice Depa rtmcnt rxcrsonnel indicJte the average response time to this pl.'ojeC't would be 1-] l minutes and tlli1t thi s proj eet would not extend prcscnt patrol routes. No additional police personcl will he requirccl to provide normal protective services to the project. , The project is I:x:HJI1deu on two sides by public roadways thus faciliwting access ,mu ViSU,ll control from patrol vehicles, Additionally, a priv:lte security p:ltrol sCTvice will be retained on a continuing lX1Sis to provide normal protective services thus reducing. the frequency necessary for public IX)liee patrol. Reference A. Site Plan: Physical Design and Program Section . " , , 500 S. Galena Pl'Ojcct Growth Management Plan Submission (cc) Child CiHC Facilities --------- The evaluation is the provi;;iun of a child care fclCiJity within rhe Projcct. A child care facility will be provided for this project. Space reCjui rements will conform to the I'A inimu1l1 Hules and I\egulations for Child Care Centers - Colorado State Department of SOCiill Services. In addition to interior space and outdex,r play area provided for the project gener::!ted children (ages 1-8), the chilct care facility will be LI rge cnough to abf;orb certain of the needs of the im- meeliate neigll1nrhood. Ms. Terry J'~nd, Director of the Aspen 1\10ntessori School, will serve as consultant to this clement of the project. (dd) Bicycle/Pedestrian Paths The evaluation is the location of the project re18tivc to pedestrian and bicycle path systems. The project is located} block (120 ft. ) from the proposed City bike and pedestrian trail and approximately 450 ft. to tile Galena Street pedestrian mall. As shown on the Site Vicinity 1vlap, this section, these systems arc within easy pedestrian access of the Proj ec l. . Additionally connecting to the City sidwalk system, the Project development will provide sidewulks Jlong the S. Galena Street perimeter of [he site, Reference A. Sitc Vicinity Map; [his section B. Site 1'1 an; Physical Design and Program Section t.:" .....",.. " " :-iOO S. C~lcn,l I'.:::jcct Growth I\1,H1~gcl11cnt Plan Submission (ee) RecX5:]iT1G_~~cjlitie,,- "111e evaluation is the provision of 1'crUSC reeyc] in~ facilities in the project development. Such facilities will be provided in the park g~ ]'~ge portion of the project, conveniently accessible to IXJth OCClqXlIlts and pick up of the scpo rated refuse by t he recycle center vehicle. Consisl~nt with the recommclIlL!tion of 1\1 r. Denni s 1101mes of the City !kcycling Center the Project will hCl\'e separClte containers for glass, tin, aluminum, ~nd nCWS!XlpCrS in a loc<ltion ~cccssiblc to a pa rked 5 ton flatbed truck, 20 feet long. (ff) Design Fentures for the I1nndic~pp(~~ " , The evalUCltion is the ability of the (mject to ~cco[:nmoc1atc s~fe, cOllveniellt movement for Iwnclicappcd persons, The site ond building deo:ign will permit unobstructed movement (for a wheel chilir confined pen;on) f!'Om ~ny location in the coverecllxE'king garage to vi rtu~lly every condominium unit. This is accomplished by me~ns of hydr:lUlic elevator and path surf:lCes which will not exceed 0 slope of 1:]:5 (U. B. C. requirement). Reference ^. Site Phlll; PhysiC:ll De:cign and Pn)gr~rn Section B. Flcx1r Plon; Physi cll J)",sign ,lnd Pmgrom Section (gg) ~roxim!y 1.0_ COI~2m('~cial SUl?Po I.t. F,<lCiJi~ics The evaluatioll is convcni,'nt wolking distance from the project to commercial support focilitics. r -, "..., ....',;r" ...,.." ,~' 500 S. Galena Project Growth Managcmcnt Plan Submission This project is located '~block from the C-C Zonc and approxi- motely 450 fcet (ll minutes walking distance) from the Galena , Street Mall, thus arc casily accessible pedestrian destinations from the project. Reference A. Site Vicinity Map; this section ," -- ..... '-" - suo S. Galena Project. Growth M,magement Plan Submissioll EMPLOYEE [lOUSING The evaluation is the l)Crcem;lge of low income housing units provided by the developmellt. 45% of the total project units arc designated as low income housing. For detailed infonl1ation on the employee housing prorX)sal [or this project see th", Social Facilities and Scrvices Section; 925 DLirant project submission, following. , / ~-,.,..... ~~_.--:-....,~....,. '-'-"::;':."~'''-:'-- .~ .'1-,.,...,.-......".._.-t";,....";'"'..::~ ';:-' .... _...,...___~'.___~~~~e',..._..;:'':_~.....-....- ... ,- ........,' ........~....~.__'-~.'_~'^-.". ~~.;..,...............~ '_""-""-''',,,-'k-''' .____,. ~._'---'."_____-_ I ~. .. ....~....;:.,._'" :->-"" .:.....;i..~.....;..;_.,~..._.~,.,~.:..:::;>- ".-.....,-,.~-,.~- / rVlr:E S1AnCf.l /lrG'iCE. 5TATIc;J H'<6!-l\J-W 81jI1....!q ST.----- -(~~._,,<:;:J'TI ;', ;:';l'~.:::;::'5~_:D1~~-..r:~~~~ rm-o.!:r#~':JI"~ " r';:,~'~ ~:::,2<~ E::~:{c;:l ~':;,;~':J I :" UtJlll-Kr 11AL1-'-' - - -- I W...fY f\t:K 5r^nrA-J-----~- - -- , "r,..;,'" :y." "co ,', '..;\ ,; ",,'" , , .. j n_ "~",-~.I-"" n . \~-~ ____H..:::r.-...;:::_-:":lH.j--""..""',...(.:'+-- ~---DJN\.J-n t.\E.~Ut:. ; M fNI1: -- ---~- T ,~;;:7~11~:D'-;1i::;~~n'_.~ 1 \) ~~1:~~~j~~.':I~~1~~~~~ , ~:~~~I: ~.7.. ~~32(i)1.>o I S~?)". -----unu m_LL UFT 1 I, r:"\I" ,~" "Jr,(fj '\'>(~ ; rt:lfF..JHv.L r-L"':> lCOf'_______.....stjiL:.:J.:: ::. .::: ::..~~~~-? !:.... .:),1/ Bt: -B" I ..: ..' j. . '.' ,:'. ,// I>' '~!" "0 V(';' , " ':"1" 'I: "11-1' ~ is "8, I, ~lJ).~ . . ':.: . .: \..:-:~{{rn;~~) ,tg cJ.---~rrDfO':cD CITY T~J'JL : ,~ ;'\, I ' ' : " "t ';'V""'~ E," \ IJFTI,A---------~n\'\,lC~:,},::'~,j)P</ \:e../_____ I w""~ c~'k)..'," \),-'11'11 \ 1 \~~ I~JJ \ \ ------.--.-rrOJFLT YTE 1 -1llJJ\ ~- , -- --- _n -------G,\LE;!A 5P;EI'T I \ \....- ..-------MILL snUT v , tl 1 IillT:S] W~M:S[>IAL em: ~~ (LMM:r;!:tAL lPLX;E. [""]ID,":, l HlllTI K~:WctlTi'l'I,,'LC[;0[ PCA"''', 'f"V I' r.:i{~,~'~l m::K/ ,; ~ _ u / Vicinity Map ~ -- , ~ o :too 41)() , '" ~~ j i .~."'--r"'~._~" -':'_~"","",,-"'- ,___._.. ~_.....,....__, H""~'''' ._-~.'~ -~-~---'., ~,..,~_.,~~.,.- ""~.-'''--''''''''''~-,-' '._-'- ._[~ ...~ ---.-" .'~ -j, "':" '. ','. ':'. ;.~... ,'. _ _,,,'-",- ."",_:"..___.~'_."'___'u_.'-.~'. _"'_"_~""""~"__'__ "".,-_,.._"-",,,,-,'- ~.~~L~_~,_~"",.... ~.. ...<.".~.......,..,-'-",,,;---"';';.: ..... ,,- '.."":"..",' '" ,...",'- "'-'-' "'-, "''--~'~'-~'~'"'''~'':''' ^ ...........-c-r- "': ......,-.,. .,.-:'"""'".....,-.~ '--'~""'1"""''''''''''''''''''''''''-' 'r'_",_ """:"""- p."'., '-~." ~~";-T-__-,..' '... --r~-""""",~ ~~, -,- --- --'"'_'."'-'-~-"-~ ...~',- ~~ ~~~- ~...- - :., --~. I , -~...- ~.~,-;.~---.... . I , i I " '1 , j I I . -- ....." , ---li.e:;' 1 'm",,"~ ",", Jill.. . __ ~__"" 'jR\J:..._, Il -"~"-=~~i-"''--'~~>l r-- '. ' /AJfAl1f AiUUE- ...N,~ .~, '~~",' =', <>=.= -~~t-r=;:- ,..,=,~~~,___",. "'~-~',:""J --""0" cr-, ' ,I-h, L I (--"C_~~---IIWP--'-- - -~~'<fJ' i IltUW,'f -'--';0,,1-'- r, '''r, '~F, "tn j I" Ii'" ' t!J,}', I I,.J '-, LI , "__ _ _ L ,I l' ~n::-;rll_l'; : ~_;,.";,.,._.",.,, U .icJ"_ ",. _'" "'1 unL, H:LL- 1 -.,- _'_"_ "", I.., "" , ' . --. . . ,,""1 " "C- ...... ~'~~~V1[":"'''J'.,:~~="=j, ~J ~iV:7L, ~_~_""".. m_~"" '" ,.\-_ !'l/L._. ~, I I I r fjj ~;;;l~n~ ,=. L_J Ir.rJJifr~_ ~ r"""'~,,'.r:T:=i~ II (; "".'. =. ALFE~ WCK-- - (~~~J (, :"i '1:"']- .~ 'i i ^" tl" "'-"'. ------.-n-----ST~: Wt;o,; f1f' V 8.., _ PJI. .- ~-=I_-~- II]e i.~. -.'-:1 ~, '" .. ',', '-~.._.. i rVfH'TW, w., Lm" /, , ! I r i' I, I I I i I ! ! I , , ,""",,,-.- i i j I 1 1 j I' I I, I i I I , i i I I i I: I l l I ! ! f [ f. I I " , Site Context r- ....--J 400 , "'" , '00 /'';\ ~ I: ~ : .-.~~-.-,;-.~ -"~.."--~..<.-~...., '-..~....,..-""..-.,-~",--,.., li,~._.....,..'''~ "-". . . .~ . > '_': l ',' i r I __.. '_,_.~.._ L ' .. ._, ....._..,__...'_, . ..:_.-...._.~---, .---,',-'-..,.,..--,- --~'~-_''"''',~.'''-~-~""'__~_ '--r....-- ~- ,'/'.,- ... , .. " ,.' :.~' ;-'--<0.'- ~',.-,,-~..----- "'- - " ---"'-~. \ , I " Fj2'."" , I':;", " ~J ~; u ~~?:, r, $0<"" ~~l'/J ~'" ~ J,~E;H; ;~ [i'~t.7 :::}l ~ '~/~: ~:~::;~:~~(\ '::~~:] " n ,1,"'\ ~: ~:~ ~ ~~:'.~ ~,,: (,,'-,'.,i,''','' ,- :.ri to' .::":..,;.:.:.-,."..," , ~': ,:... tr:"~i'~" ',,'\/ L1J cl [;~:'):1~\ ~::~';""_i1 i_I i-1 ~ n C.::)._.... H.! !It" ,- - 92S DUI,:,<,~:!:",PI'ojcct ..... ,-' / Cl'Owrh M:IJl:lgelllent Plan Sulnniso;ion Submirred to: City of Aspen Planning Dep:1rtment 130 South Cillena Street ASpCIJ, Colorado Applicant: M1'. lJ:lIls Cant nip P. O. l),,'}x 388 Aspen, Colorado A rchi teet: CopLmd IIJgman Yaw Ltd 210 S:,uth Cillena Street l\spcn, Colorado i . ., -". ---, '~ ~ - 500 S. G81ena 925 Durant Comhined Projcct C rowth M [lIlagcIll el1t , Pl8n Su hili ission GENEll.M _ !,EVlEW INTIl.ODUCTION Submittecl for Crvll' review 8S one project this submission con- sists of development pl[lnning on two sClxu-ntc l8ncl pnl'Cds: The 500 S. G8kn~1 portion of the pl'Ojcct on which (16) free- markctunits-iiil,r(l) employee unit arc pl8l1lwd; the 925 Duranl: portion of the project on which (12) low income studio units 31:'e pl8nnell. The respective loc8t:ions o[ the two proj eet enLities are shown on the Project location Ill8P, following poge. The review criteria denoted in the Growth l\13n:lgemel1t Allotment Applieatioll is b:1Sic:llly, nnclmost easily, structured [or evlau:l- Lion o[ [I project prornsed [or devcIopmelll on n single- l8nd iX1J'ccl. To facilitate review and cvaluation o[ this project, which combines development on two land p8rccls, we have submitt:ed each devcIop- ment cOIllponent in a sep~lI':lte scction of this portfolio. Eaeh of the two parcels proposcd for devclopmcl1t have been treated in- dividually as to their respective compliance with C;,'AI' criteri:l. Thc SUO S. C3Icnn porrion is discusscd in the first ponion of the submission and the 925 Duralll pOI'Lion in this IXlr!:ion. ( ....~. ~ ! .....;.'" ....... '1':1 ....1." (<'< ..__iI ((~ ..n." 05 -~ ::-j .~'''>''' i ''''.1 , '1; ! :~~'" i \cc."~ 1 01 I fr ~.) I CJ 1 (t) i (fi l to I ~:) \ i J ) ''''''', -- ''''' - 925 Durant I'roj eel Growth Management Plan Submis~;jon 10, !'rogram Na rr:1ti vc:. The site plnn is org:lIli zcd to c rc~ate maximum open space fronting on the public (Dun1nt Ave.) siclv of the project clevelopmenl and to permit the sU1ggerccl al-chitecturnl form which l"cLltcs to the residential scale characlcri zing the majorily of stnlCtu res in the immedi:Jte neighb,)rhoocl. Thc building is org:mized in :1 2-1evcl st:lcking :lI:rnngement wilh in- divlclu:11unit pl:1118 st<1ggerecl to permit multiple view orientMion and to further reduce building sCillc. Consistant: with convenience and vis1l81 objeClives the required on-site parking is locnlcd to thc alley side of the building immediately adj8cent to covered p:nhs and access stairs to thc inclividualunits. Utilizing conrcmporary form s and components, the a rchitecture of the building ilccomplishcs ;1 victori:lll scale in its facade clements, Masonry beilring walls, wood siding, and projectin~ b:llcony clements chi1 racterize the e:-:lerior design of the building. The site will bc Lmdscnped to create [~ITenslx1ce nnd privncy for the lowcr kvd units. The F. A. n. permitted by zoning is 1:1 or, 12,OOU sq. ft. for this site. The project del'cloplllent, compl'lsed of 7000 sq. fr. in [Oral, use,; only 60% of the permilled Door :1 IT,). The building (oolpl'int o[ 3300 s. L covers only 277{, oflhe available land pilrcel. \ 11. Su rro1ln~li\lg Zoni 11.12: ,me] LlIld Uses , As shown on the Vicinity 1\1:lp, the project is located on Duront Avcnue, east of Orinin81 Street:. The project ,ll1d the immccliatc cnvirons are zom:cl RMF. r' " /-.... " " ~--.., ~. . 92S r~mll1t ~'rujcct Growth tvlanogcmcnt Plan Submi S,iion Surrounding Joncl uses are lodges. condominiums. apartment units and assorted Single-family residenti,]l units. Building complexes in the immedi:nc surrounds ore: The Alpina JJ<llIS Lodge; Silverglow Apts,; Chateau Snow Lodge; Olclllunclrecl Condominiums; and The Vaga IX1ncl'j "oclge. / /' (~I .,ff~ '.. 11\ /:c~-:.:j~ ~'::'f'i 0-j'~"" A("'::~': /' , t::lj:!h.~... . ~~t!'lt~ II,..C.III."" 1=,1"'""" : ':L~:f:..~ t:~:;:::.-'t~:~t~:~ I j I:!: ;~1 :; i i':~ t::::: ::~ \'::::j':;:: [I , t I ,. ~' ... , - .... ... . ." .... ! . '''1 .. "I' t ~"...... ,....,..... d I\~\f:.\~ ~1:l~1 \:;::,:~ [.\I~m~:~ ,.~,.>' -~ 9~~Oj'~UC' ~ant () i:::til~;i:'l ",,,.. ...,. - " '" It:'::: ::.;;~ l:i',,'t;:::::::::: ,-c.::""- , 1 r:::-S ~.::::l [ Jr",:::;.';>" ..' ,.... 1 1 ". . J ...pH I I' . 11[::::: ::"---', ;, "_,,i:":::;: . "'" . ,.." ,..""," :::''':C:, -c;v i,~J. / ~~~l. :! f[;li~lijHW 'l:t\TI~~ ~~i/~n ,~~--'- cP w:;/, VC'IM~,,, ,(,.oJ" , , ,11" 1.,..J ~,..:,,)-, ,t,. -"''-'c'-. ' yr - - . -- " (f .- ell"~ -r f.i~-:~~ t:~~~~: ~-.:~~t!:.~~~,r~I-~~1~:~::~]~~~.~ - -a , ';{ )t~!\~1;",;.,1r::ljl.fQ~t I1W' . 0:-:(o,r::~--<-.";: , ~:3!.;~<._:<DtllJlll ~'1..t~l (~ <r'\ 03J (("C",,' L__,. =-_1. =:_-::::;.;::JC./~: ~..:..,-.::,() , . _ q '1:", fl/ ~ '(, ' . ' ,'~ '(> <;I' ~ I ,'.':>":-:":-:n ')i' j r ~', ,"'.'.";'1' I V-.....' "<J'.." I L "",I '''Tn ~:::,:'::':-~p" ~f,tf;V'P UL L~:; >}:~:;::,:;,,~,~!: I - . . ."..-^........x .v'"'v~. c.n.. ..~~ j I ,..,__ - ~.~ -, -~-.. --- .---- ---.--l, ;;> !/V~O y!.'-" ~. i~'PP".", ,v<p ""'''''~ ,,,,,vpl'I' I " 4 >.'-':::'J"J'.:.>.~ <",::::":,,,<,,;::~ ~.;.:<<-; /~) ~.: . >:....:'~'\J "lX} f' J ,.... /. \.':x .., ." ...J'...... '--" ,'",. ,,' I' tti'{Jj ~ >:-::::"">~ >.':': :.>>:~ ~;;'>?'.":;.<) ;::: :'::'':'';:;'1 -, f{)~ ~~(;::;[~l4~'j::R-V(:~ j 'j<'" .",' c;>,'-:,:-:-:,/ ',','. ,',. ,) ," ' ',' 0\-:,,' -, ',' (,'1 1 ~:-:>:::->:;; ....'/."'..'>:. ~/X.\;,: :).:,:;1 ~~~::'~ :::.~:\ ('1')) ~d"""~V <!J'/......' ;:;.;<,:\.;.:) /....,...'\." ,/,'" /'vl' '0 ),~. ///.......)0. '-,," ,/"" :-...,.......,.J' v.' ,,','- ." '\ Ii'" j:..{:./;.A:...\\'x :<.:,;-<<'Y--x ~,',<'^>(>>>,X; ;-:"<'J':;~>S:~fl jl~ " nV',"-1V~~') ~""0::--""j rv)<~~"'>^" "~"'V,..,...I, ::Z:"l''::J ~'~ .f',....,'.. \~"-' ,...,'''-~' . .. J ", x 1,..--:.",'.-:.":.-:. y',,,", . . ',-1 ~'. \. ,-,<.'.:<'" < :.:< '...,,"-:'.;, ~,\.\. y~r-) .' "<,""','~">)'" \.1' ,.- ,J.-\.l ~ S <::<:.,<::::\ <. ",' .:~>'<~1 ~>>:':':,,;:~ ~,>:,:, ',::;:r '1~\.'\\'~'~:N"(C5D,S~\:t ,/ ....-:~500 O. Galema 1 ,\>' ,\ ",." ,),> / ' " . " ,',.",..' :::::" 8 .'/",/(,h. \0'>' #" P . T.. ;. " ','t~ ') ,....,., . ,.... ..:.'....'..,,'x .-"...'......,..:;1 , '\. I : .~. ." ~'.' : 4..........~. ro"~c"\- ,.' .', <1" //"",,", '. ...../.',...... . """, 'I'" '......, ......--:>:.., J'-' . 1(,."""\'" ..:-- '. .''':'.\.-:-., ~\...x'..,.,.,,' :','.':'.':',\.:' ,"',\::9\...: ..........:.".,..... '::.:. 1/"" .~ \)".,,---....'\ ,)'.,,"\.',''--,\;.-'',....'.\ 0'''&..:............(:',-:.....-~~ 2s.:....'\....<', -f-Jr . <X>'>"'J'v'.\~ l;'~'('--'l\.;-'6 > ~.~ :"/,;.; ,'';,',''-.'' :. :1'.... -- --,:. ...... :. ~ . L_,"~" l' 'j-l~ l . . .' . 'I ~~.: :,. :':-;, ;':Y0'"':-''' f)":';:':"""{'l { "<'.'n,j\. ,11:>,\' ;~~:':';"'., (::','.:. ::: .:,::'., -',," .>.' ,'.', ">-." ,\.\.\.\ (v.'. .'0',',) ,?:,\~A" \1 ~,,\. f...,\...~:.}';--...'-...- '::.......:.......:. - ~~L ~ :s.'.' ',r~' >>~"<,' ,/'.:...,:..'<<.111 "". ) ?")"":-:"; \':':;; :;.)-)-, "'J:l'[F11cn";~... .." ""'=== >:.,,:-:.~ >t >-x.\,' -....'" 'd 't ,"'<.:-..';...:< , l (,,\ ( <<\ ():A:', . . .:: '. '.::: ;::', ':,"J : :.: ~--.~ - ~~ ?"", " x",-""<,:,, i/....."\".~) \ ",y.'."" ..,... ' 'J ,.n.. .--- -J}-' ",,,,,\.'.,,,<,,{"\, :"':--"J',",\.,~l v.,'.....,.,\;{ (,'-. It''-', ".I'" ..: ..... ....:......1.... 1/>..,,\'.,"'~--.....,,\.,'~\J'('."x'\'.;,").IJ'l:X'\:' If'I' "'~)':'" :........ ......., ....-~--- ----- I,' ,,'>..... ...":'''' ,/ .,.,..... .:.\~::, ~~/y~)'l. .\',: (,<.~ ,'nrO j ,\ ,d..):....:....:::::...:,.: .:'~ ; ':.'-~ - - - - l~~~~:: ~>: :~:X~\~'1\? :__-:~::~1~:-';:,:~ ,.,~:h~'~'0d \. \.....~-{;~.~~.. mlil' Y\r{,(~i'" t. . ~ . '-'~-- ---- -~- ')X:>" .'\.\-"j. ......>.'\..^..:,,'0::.).~ \ ";)}~,,>-~trJ ~~;:'li\~ _J. ..." ~(.):"'" .:. .1.1..... I . ~,.',u. '" ..-:.~~ -II l J' ,..>\.:.:'/''1 ",..;.:..'->,':.. _.,:,,1 ,,~J'- t, ,-Y ) ,.'t\] , ' \. (\.5..:-". .... .' " . . . .': : ::'" .,: '.'B q ../ 1 ;';",V.',<, <, '\ ,',",:,.' ~. RUlJEY P,\R1(/ ::<~, 'f '\1,::1".'.,:"..,.'....... .... . :. ':1'2.:.,,?Y :,.:-...:-,',.... ;.",>< ').; :.:-....,'. '.';1 ;:, ~: J~..... , (~...',:,:" .... :'t: ..' :. ..:.... ....:7: ~'X':'0:"~'~ ~>:-;;:,:".~"." ,,,'WAGNER P{,hK 'i"" ','- \~),:::' ,:,.': . . '. .' ;'. .' " : . :- ':..' x"",'. "I'<',\"A""'1~,J - C ','r '.....'-^:.,.......... ...,........... . . "-., '," ." . " '. - \ I,)(.,d. <;J Y u' J-:) r< ) , Q-)' '. . .,. '. . . " . h^.^A.....\\:X>, x'\.",v..'\~\-') I--'\.. .~(,.Y-T\J.""'(?'-) \. ,1",\ (.;:.) 1'4- ,,,,~J"'" " " :.... '::'..:.' .., ~.. '. . . _.......v-~ ....-;}......._...--.-.".-.....,. -- ..,'_:.;.-- '-1, -\-: ,,, ~""i'""""""""''''',,,'' J -~---' ,-"' ~.~.._.~ ~--'- -~ ~,.~) .. ~ (~01:CrJ. :.:.::'>,::'i.r:~a&n., C~A' (~~ 0/ / / .--"', ~/ -.-Jt ---- 1 ,) ~ PRO,JECT LOC!~T!O~J /'1'- .,OlJ \\flAP' r~____J o 200 400 GOO . I"'''..'' ,-.... v''', '... ,. " ,,-- ~'-~\'_~_~ ."...._. '. .__.~.",<...p._^..,..., ,.._,....~ _ _....__. .."...~,,--:~_;v.._~'._ ."~,.~<>-",--...,~ _,,,,'''_~'r-''._ ,..-.~.-.- ,'''''' .,...... ....,c___ ....~.;i.1;.../d.; //"'/1 ::'~_:''''''J' 1,~_,.___.___==-~/:~~1~'~~:{~{~:'J-3::::~ I 1 1 1 1 [0 ~:~J,E:-l L~mmo~:] L [] L-~(1 [~-r - i-r L-~-1-l ['---1 -+ '[-'''-'-1' " ----- lu~[-- . c:.~ _ C,J. -~I Silo Plan 1 925 DURANT AVE. PROJECT -~ \Lc__::~-=:_- ..__~D._ '. ,,_,__[ _.' ~~=L 'r~' 1;_. '-';'." i " :-.... <<'.'-, ';', 'I~,':' - ~':~_;-:>I-'_'-."--' l ~ ! 1 ~ I I j " i i I i i j 1 1 , J I I 1 1 1 ,l__ WEST END ST. ',- / 1-_---"'1 __,__1 \-L r'" , L I -llLl",-1-:J~':, . [-----'~.. , - ',',\',-,"~'~"'~"'."".~<""II. \1 """,,-.Ii" . 1"<"'". ~~ ;;/:' L>nfk'''') . (1\~ ~ I ". J \) 1-. .i lollMCi yj"'''' L>, ' "';"-" h ,.~ ) '\'''1'''1 ,..., '{'Ir I I -..l,.} '. ~ I i-.</ .....,1 :,''1 .: :-r'T' ,"11 .. , .' .' '.... I' ~--~Iill".. ,... '-.' )")'f" I. , 1 '..'.<Ii ;''-1 1 :"[ '~. ,. ,,~, .,' . ..___._. :~. ',. J... .'" i . 1, ".,' I '''I I, -- , ---~..Y'. 'F? "'-{.::<>.;:; :~1 1------'1' \, --'. ,..L ,I \ '\:J:'< '.1 l I,",~"",, . ""',,' .,:,11 ;,1,; 1,':. ,', (.~"'G' I ,.:, "vi., "'1' .. ..,~v\ ' I r I"Y;:"'",)." ,: {"I:'-i ! ----...-" ''-. ~'><', '. ., I"" " I , \./"".""".J',":,l "',',::. '.: i\1 1"""-1' : I I '" ,> j" : , "," i",' -.. i : (:;,()'-~~'.'<l-.._,,_..,-; .~:. .'.1 :',,: ..~-:.:-~_.:,--I._ _...".---'-,_. . . :1<-'. 1-.\ I ! - --~__---_-_-~_3- J"~'l ! , I \ I r-' l___rI '-- _.-- ~,___......r r-J' [-"- "".".l~~'~_~~~~~~~~--".. -,.,. , .1 I) I " --._-~.., ! \ (. I I I , r . I: " I". l I' t', t p L LO ~ t: ~ a: =) o i I:i n ,;__ ...-......'__... ,'_..~_.1_'....... ____..~ __ .'.,,",~,~ ''''''''..'*'......... _.....".,._.~~.~......:."_..->.. ',~~.,~. ~ _..__............_.--.~:.., ... .~.".;;....;.,....:..~..;~...... -'~"< __....:......__..~-"'-.J . ""'~." .'. ."..,.,,,-,...-., ,",,~,---,----""':'''--.''''. ,,><,-~,_,,"~,'-'-"".-"" ~,,",-,,,,,,,-",,,,-,----,""""'-""'-" r"""'" , I II I 1 j \ , I 1 1 ,j 1 j 1 j , , i I I i I j j I j I . I I I , 11 1 i , ~-,.,...,."'---..~. --.. i I I l,_._~,.. .. ,.-.".-.---- ~---_._--- .. \ I i H I' .~ n' n-rl , ,--'" "'''T' 'I I ... l .~ ,...1, :'. , ",.,.(. \) >', ,,' .. " _.l. 11' I '. I ''':I.\i Jj . ,; --,["" ; r., ' '\ r,c'l I. i r ' i j, '.IF j''' J,1 r '-~ ~Ct;,;, ,1,;, ~ "'.,~, ::.;:,1i,; J' I,}f::,\ \ "', I' '1\':- j j .ii' ':.l .H ~ l; i~ I; "i i 1 " 1-- J'.' \..' ., .1--__'~;_'~ '.~.;-,-~.~ :!..,-:l., L I . ! ' '.':;:.. ,- ----.,.~.-.~, -...,.,-:---." ,~--"",--_..........-,......."., 1.';- . --,,'--T.--r"~'.(''''''''' ...-..-."'....;. .,-...-. 01;..- '~_,,~_'_,_.A"":'_'__:';'J~~"",",,_ ~,'_.._ .,;....;~.;. .-....-:.;....;...~,-~-.:........~_.--------- -~............,,~.....,...,... _..,.----.-.-."-..-.,"<:...........'".-"'.",.-~......"..,.._,..-.-.~ ._...-"-'-'-,'i...~-'-'"..--"_...~.. " r .... 0: o Z I Z o ~ > "J .J W r o .... lU Y- U} ~ ARCHITECTU RAL ~ o 6 10 20 , ,'..."......, _-.., "..'~.:-..r.,._'._.~'_ ~~ ._._,....,........--.-_;O:.~. j-. "(-' Ii f; I' 1'\ P l! l. i' ,1 I: " " " ii \J L I l' i' .' 1"\ i! t" n p: U t~ , I: \: ! L I I I r r \ [, i: ,i L t, Ii I .0 '-i I I, I, t; I .. -" .;..~"~...,.~""'~_.--.. ,.~...... =-.', ...;~._,.- --._.-~.~. ."",",,,", f!{~ <."J () ""'.~ ~--. Ie \ ~~-', (:,j 1 i I I j I 1 ) .' ! , , , ! , ,.>',~" ..."" .....~,/ "--.,.." 92.'i Dur:ll1tl'roject Growth Man;lgement FJ:ln Submission PUR] ,Ie SLmVICES -~------~~ (,\;1) Wnter SY..:c;t~ The eva]untiol1 is the UII'];lci! Y of the public wilter system tel provide for the needs or the pnJp(lscdckvclopmelll without t nCiHl11cl1l p];1I1t or other facility upgn)(]ing beyolHlthose provided by the dcvclopeL The projeCl w;lter dcm'lI1d is din~ctly rel,l[ecl to the rixllll'C unit count, consisting or] 4,1 F, U" whicl\ converts to 55 Cl'M m,lxilT1um probilble flow (1}" Winer service) or ilpproximately ]O() g:i1, /cl:ly/pcrson as peL' current ASI mE guide sta ncli-ll-c1s, Tile project il; prcscnil y served by n 6" water m,lin 10c:lted in Dur,1I1t lIVe" ndjilcent to tile project site; which wi]] provide good flow <It mlcqui1te pre,;sure to tile pl'Oposed development. A project revic\v by I'dr. J:Hnc,' tv1:iralul1us ilKlicntcs that no fore- seeable dcfjcjcncjc~~ exist \vith regard to providing \vatcr ~;crvicc tll: m1cquDtc pressure levels ;lI1d no ,;ubA:lntive in'IJ:1C1 on the treatmenr pJ:lnt, which is currently utilized at :lppnlXim:lLely 75% c;llx1City, wi11 rcsult from the project developmcnt. Fcfe rcnee A, Site ConlCxt Map, this sectiol1 n. Project review ]cuer from I\ir, James J. M,nkaJlll111S, Aspen Welter Dcp:lrtmel1t, this sl,ction (bb) Sewer Sx.~tcm The ev,1111ation is the ccl[J:1eity of the public sew;ige dispOSed system to serve the Pt-oposed development without system extensions ane! without tJ'C:ltment plant llpgl'ilcling. The project site is '3ervcd by :1n existing 8" sewer line in serviceable conditioll extendin1', along Durant Ave. and loc3ted directly adjacent to the proj ect site. l ,,,,""<<" "'" ,..J ,"",; 92~"ptlt:il\lr J)~.'2!ec~ Growth Mill1ilgcmcnt Plan Subnlissioll Applying the Colorado Stille Li"IXlrtmcnt of Ilci'l]rh st:ll1c1,lrd of IOO/g:ll. /ILly/person to projeCl OCCUIXII1CY stand:ll-ds of 2.0 IXTsons per studio unit, the toti'll pmjen would gel1enlte ollly 2,100 gJllons per dill'. This lI'otJ1d ,ldelle,;,; thJn 1/7 of one percent to the plJllt capacity, thus is well within the service c!p:Jbility of the pncsent ei'lpi'lcity, A prcliminnry project neview by Me lleiko Kuhn inclicntes that no foreseeable deficiencies exist with rcgilnl to providing sewage service 10 this l'Jl'oject :Im! no subsUlIItivc imp:1Ct Oil the treJtment p!Jnt, which is cUtTently utilized at Jrproxinwtely 7S'/!., capilcity, will result from this project (kvclopmcm. Hcference A, SiTe Context f\bp, this section B. Project review lettCl' from Mr. IJciko Kuhn, Di,;tTicr l\1Jnnger, ASDl:n Sanit:ltion District, this scct ion (cc) ~.onn Drainagl~_ The eV8lu3tion is the G1[xlcity of drclin8gc facilitic,; to nc!equatcly dispose of ,;urfcJec, runoff without public drainage system expclIlsion. The dr8inagc control system for this project will collect :lnd ITti1in 811 site, runoff i1nd intcITUjxcd sub~3urf~lec flow with on"site drnimlge fi1cilities. The project sh8ll have 8 m;rics of dry wells nnd retention wilter runoff. Com:isti1l1t \vith sl811lLlrcl enginecl'ing practice, the dryweJls will have overflow outlets cxtendinc; to Durant Avenue. , . Hefcrcncc A. Site Plan: Physic81 Design and Pl'Ogr:lll1 Section / , ,...-.' ; 92,,) 12l1..nln tJ2:.~i ec l Crowth M~nagcl1lelll Plan Submi::sic)Il (dLl) Fire l'mlcction --~~~---~- Tile ev~iltlotion is the ability of the Fire ])cp~ nmcnt to provide fire response to the project ClccOl'ding LO thl' cst~lblished response stanch nls. The project site is located ~lpproxinJatcly 2l0n L. F. (5 city blocks) from the fire ,;tillion and Ciln expect a m:I:;imum response time of 4:\ minutes 1'1'0111 alert si ren to cquipmeJ1l 'llTiv~\l at site fi re location, The project sHe i;; served by (2) ilydranu' with ndcquilte stntic pres- sure for fire protection. Two c!djacent rO~ldv;~lYS, DUnJl1t Avenue ond illley woy, provide immediate aClTSS for fire vehicles. The building development: will be additionally protected by a dry standpipe sy:;tcm, ond ionic smoke detection in individual units. A project review by l\h. Willard CL1[Jper indic;1tes no foreseeilble c1cficiL'nci es exi st with n'lY~l I'd l'O fi rc !lrotection, " Hekn'ilcc: A. Project Vicinity Mol', this section B. Site Plan; Physic;ll I'ksign ill1d Program Section C. Project ITvi"w Jettel' by M r. Wil1ill'd C. Clapper Chief, ;\spcn Voluntec:r Fi re DC]Xl nrncnr (ee) ParkillX Dcsigli The eViJluation is the design'of required pill'king with respect to visll~J impact, ex[xlscd paving, convenience and silfety. All rcC]uirec1[xnking for this project is located c1ilTctly off-alley, pcrmit:tin~; di rect access to individllill units via covered walkways and st8irw,1)'s to upper levels, All pJrking is ViSlI<llly removed from Durant l\vcnllC and public pedesl:1'ian routes serving lhe neighborblXlc1. / IZeference A. Site I'J:1n, Pll)'~;ical Dc:sign & l'rogram Section ,..-',..",. " ......... " 2.25 Durill~t Proj<:::ct Growth 1\1 ,1n~lgClnc;nt Plan SuL>lni~~sion (ff) l\o'lds -- The evaluation is the C'P~IC;!:/ of exi~;ting rOclc1s to service project traffic without subslallllcllly ovcJ'loclding or alt:ering traffic pilttcrns. As shOl'in onlhe Site COl1lc:.\t Drnwiilg, this scct:ion, the project: is 10c;lIc(1 on Durant J\vcnuc appnlximmcly onc-h,llf block cast of Wcstend ^venuc. Exarnin:ltion of Ihe trelffic illlj"IU of the project is pl'ima riJy bilscd on work generated by the Uj\,rr^ t:rml'~IX)rt.1tion study and on recent convers,'Jllons wit:h I'd r. Steve Lockwood, j\leln IV!. Voorhess & Assoc., Jnc" traffic COlbUlt,lIlt for t:lle UlvlT;\ ,~tudy. The table below presents the trip type and trip frequencies per day pcr unit for a project unit as estimated by Mr. Lockwood. ThE: 6.5 trip" pCI' unit is less than the 10.0 ll'ips per unit for a typical resi- clcntinl unit, becilusc tile rJrojcet con,;;'sts or stlldio IInit,; gcner,lling less peoplc than 1::1 rger ,1 p'lnment 0 r condom i ni UIl1 un j u;. 'fOUll rrips arc estimillccl between automobile anel ncm-iHltomobile tl'ips. 12:~l2...'rYjJ,~ Estimated Qlle -:."..~l,L '1'1 i Eo;_ Estimated Non -automobile t Ii LPC rc~~lt31rc'::. Estimateel Non- C1ut:oml:Dilc ITi ps Ski ingj nce rcalion' .75 60ry /0 .5 Work 2.00 75% 1.5 Shopping nnc1 Emen'l i nment ].2.'5 750- IU .9 Personnl Business 1,00 "()(P .) ;" .5 Other I.S0 2.'5% .4 6.S0 609'~ average 3.8 /' "The 6070'non-iluromobile iwcragc for rcerenrion trips assumes ap- pluxil11alcly 75~:,-8()?Z, of ski trips n re non<llJtomobi1c bur only 50;!;,,-5570 of sumll1er recn:ation trip'; are non-mrtomo],i]c. t""'...... .., , ,.... 9?0_Dul',ln~~:<:1C'l'~ Growth Monagcll1l'nt Pion SubmissiGn Due to the projecr's conVCllicl1t location ro downrown lIspen :.1lld public transjxJl'taLion, it is cstim:lIed a high percentage (6C1% to 75%) of skiing, wlnk, shopping al"] entcnoin!llent trips will be non., auto!llobile t ri ps. lis shown, potcllti;llJ)' (,C1% of the tot;]] projected ll'ips per unit will be non-automobile tl'ips. The estim'ltcd 2. R automobile 011(';- way trips per clay ;Ire equiv:lknl to a resident's using hi.', car on an averllge of appJ'Oxim:ltc1v one time pel' eb)', The walking :lIld public transporwtion C01l\'l,jienee of tile project's ]oeotion p\u.s the project's low resident jXlpulation re"'ults ill minima] tr;]fficc impact created by the project. Current detail tr:lffie counts ore not aV'liloble for the orea to qualllilc1tiveJ:: estimMe tlllf[ie il11pllct. ((~(Y) Encnrv (,b _______.~~__ The evaluation is [lbility of the project, its spaces nmlusc]'C;, to maximize the cOII:wrvalillll of cllCrgy. Cllnsistnnt with the ";oiar geot',raphy of the site, [Ill project con- stnlUiol1 will be l\csi\ynecl and built to maximize soLn utili/otion <, ancJ to minimize heat loss, thus reducing the demand placed on the fossil fuel resource for ,;p:1ce heming, The fo110\'.'ing techniqucs will be implemented in tllis prlljcCl. In,;uJarillll Signi ricllit]y exceeding I'l'glll:it:ory 11IL'l'l11[11 st:lIld~lnls, ext'c'rior Wd]]S wii] be inQ1111tccJ to H',c26 to 28 min.; roof composil.Cs W 1\='12; floor composite to 1\=20, foundation perimeters to r~=l4, 11 rehitl'elu ral / lIrchitecturill dcsign. configures building to optimize thcrmal chnnlctcdstic.c; of the p]'IljeCL. Exteri()I' wall eXjnsure is mini- mizecJ by maximum lmit cldj,lcency (clllllmon wo]]), elm\ by vertic[ll SpllCC ()1'f~,1I1izotion (minimum rlllio of cxtcrior surf:1ccs per sq'. f1:. of OCCUpil'cl sp;wc), i\J j bnildi ng,; :1 rc oriented wilh high use interior :~:l:-lCCS !,() tIle Se\!!-Il 1'0 :lchic'vc yi~\'v' \'".bile 1l1::1xirniz,ing 1)~lS'.siv(' solar ilL';11inp' ll(itcntii11 ,-' -. .. , ,..""" 'j "'"..~" 22S_I].L.J,nll~~])1~0!..':~t, Crowth ivlilnagClllcJll: PJ~lJl Submission Clazed openings on Ilon-suuth CXPOSUl'C'S will be limited to Uniform Building Code millimums (to comply with vcntilillion requirel1lenU:). Opcning surrclunc: c1Ullils wi.ll be I'cquircd to minimize heat loss due to infiltralion, Totally fLit roof surfaces are dcsignee! for allunito; to rCUlin the addition,11 im;lILltion value of snowf:111 layers, Devices ('"onsi stant with solar geogl'aphy of site, sola r collecton; will be utilized for domestic hot water Ilellting. E1ccCl'ic energy will be designated for prime! I'y srX1ce hee!ting to reduce fossil fLld demand (approximately SO;Z, of ('kCl ric IXlwel~ used in Aspen area is hydro"genernted). j\ulnmll!:ic thermostats will be specificd to. conrro] night lime space ICmperJltl11'Cs. Fireplace design wi]] use double damper control, exterior combustion air, glozed fire olx'iling, nnd hent return ducting. llumidificnl:ion will be w;ed 10 reduce teIll'" perature reCjuiJ'ed to achieve equIll cOIllforllevc1s. Heflcrellce A. Arcl1ircctlll'<ll Drawings; Physical IJcsign :lI1cl Prugram Section . r' ,-", '''' , 11""'" ._..._, 11 1\ lJ I j _ ,,'""~"__"""'_~~"'_' _'h"~ ".-.-. ....-.,,'.,--..... ._,..... ._.~......"_. . ..~......,~ _.~~ -. ""L "';T>-\~' i-r-" .>.1\1'...,.... / / IHICt <jlAII[\\ f{iGf{\,..,rI\,(Bl/___._f(=,,",=-=r_=-"'~"'''''''''~'''''''_'-='''' I' ,...""f,,"C';>'-.-' ~ t.~;'C",...;_'::",""""""r:.~ ! twlJ ''lrh . I".',',",'..." ..... ,,,,'," , ... \ i J ,C ~@':-U'i (,;,M/{:", .~ 1 El'~oT\N0 tv.um[\.l:~~t1~t"0.~ ~ i ::':::~"lJJ~ltl~,&~,;&1 (g,(~t) @;0$)!~,i~.',,~{i.,;;~:i,i~~F '"' I "', .. ""," ' ,.'...'.. ',< '\"" .1 c.,...."".. ,.,IIJ- '<~"H NlI" , '1""':'" III 1'1' I' .,~ i ., I It. . 1''''1[' \ \ ' I 1III 1\.(t~\]lli 1!l1....~ I '(c' III '\;'t1 Ii ~,,<J'~ ..~ .(,I.lOn' PilE r7\~K ['II,' ..................- - [CD\?>:EI7 (.IT( '" rr/l.iL i ! 1 f1 ,I j I j I I I I 1 j I I I I' I I 1 i L.._..,_. , 1,:;:0-"'1 &-ij COt'li'1CKctAL Ut.<E lliIil;ll~ RESr,HJJ1.\L(i1ULJI-t/v'liLY nn'l';rllil~ l:t!lr,;r.,.,'".\ ',!,I /-:- ~ll ~LLl! ~, N '\.... <v ~T'ITI 1:[''l.1.'i:n.^[.. I', UlJl, , ~W:.:;"~l 1"1'1' II' IPJ II' L7.-::~.::J t',\:,/ :,VL-Vv Vicinitv iVlCll) , I ((3) ,...~ .....,----. (, ~")J 40~)----~OO 'I -~._^-~....... ...- "~'--'------'-''';r--''''~''',,'''''--.-' -.--~- ..... .:"',' . \:11) ..., -,. ~ -- ... .".......,,--.--...... I I 1 I 1- ' 'I \11-h!.f'.QN,) LDCV[--I---j-" ---,-..-,- ;'''""" f.'i), V=; ','-' , l' CW 11U11Pr.EV cww>~-I-ic'l"'lr,!Tl':"70r)irit~:l UJJ[Tlj ~~ rnljPtJ' :t L:::J h, ,--",.,J l' I IL r I~ 'u I nJ""T "i' 11' 1<::0 -_.~._- ' f' j I ,,~ .. ., / II:.; ",' . t- ") ,~r;,"~II':: t:.N_~\-' 11'1" ' ",..~ h' c, :, ' 1 ,_,..,:~c',"'::1 I'"~ J /1, ", '," 'Tr-, -',,-'---r-~{, -+.. .,~, " "'" , .>, I ,J ""'i< :,"b"'" i '.., I \ U 1,lr=' 'f/ I (""' j.P J' ," 1'-. ,,>,-,"",c-/,"I' I t7f.t~X,['O I.LLEY ---~- - ~~-=~==--___J3:i~~_~-:~~__ __~~-t;~;JL_..Q--J ~_L')--------' l='~:-'~~~:'~'~ -T{~1\,~~,.6ES i: 11'^,TII 0nw>,c~--I-_LL~tDJrj[~~~~]ll rL{~~-n Ji~ j Cf\I<lENJ 04.?'I---l-L.=---~ J ~ -~-"----'-'51LVE:rJ)''>>w :1 WIEKS AVEJ~'jE -r--.------ --- -==--=:.::...-.::..-::-- rl ' II [1 II , 'I 1 ._...,.~-;-.. ,_.,....---' "','..-..-'....'... '-' -;."".'....,,.-.,.-,,..,, .., 1__ ...,......-:::: -~'.'- ~--'''cc.-''_' f -~~,-'--....-........ ,-...,...,..-.., ..-. .. ",..,~ .....','....-, '".' ., '-'~-'" , , "" _0<.' .'.._'-,c :L~_'._""4.<."..,""'.,.c' ~^'...~.... ~. -'-' '-- . l I I I 1 I U'A:f.lI!.J 1':'t)\'::\~O I{.J<X 1\:nSt1~f [1-:' , 1 I I 'I i 1 I I \ I-~"-"""'-"'-'"'' I I [,- ..'--.---- ,..- ,.....------~_.... ....-,.. ~'" -" ,~) '-:.v:/ Site Context r~ o ~I) no 20'J .. - -p-,,- ,.~ .i'.' " or', ,__....,.._,_...--....~,_.__~.c. ;..~",....~.....;"..~v_.._... ~_____ ~___~_.............._~"',..~._.-__~ i I t' i i ! Ii I i I: I' " " , I: I I I r' I I' !, I ~ I , f " i , i " !. , L r j: I !.' I, i., H I' i' I' :-i , I' I ;; " i I I, i , i ~ 1" ,c.," ..., ,.,,, " \ ") ! Cn . c" .~ o o C.,," .',,'0' ~J o (,-~ t.-" ,~,: ~;:::j , (4) J (;,; 'I , l ; ) ,..... '''# 92,,) ])urant Project --.-----.----------.-- Growth i\lonilgcment PJi1n Submission SClC]AL FACILITIES i\NJ) Si':IZVICES _._--~_._------~----. ( iW ) !.:u bJ i c 'l~ [122" I"-Wi}ll j (:'~1 The evalu,llion is the ilbjlity of the project to be serviced by public trai'Jsponation. As f:hown on the Vicinity Map, this scction, Uk' project is located :350 fl. from the East COOpl:1 am! CJcvcl[lIld bus stop and SSO ft. from the Durant Avenue and Origin;ll bus stop. Public tran,sportillion, thus, is within a Ii minute wJlking distaJlce of ['his project. l\eferellee ------- A. Vicinity i\lap, this section l3. Site COlllcxll\lilp, thie' section (bb) Police PrCll.cc:ti()i~ The cvaluiltion is the ability of the Police l:x.'partrnent to pmvicle normal protection sen'ices to thl' project with current pen;onnel ilnd equi pmcnl. Conversations with l\spc'n Police Depanmellt personnel indicate the averilge response time to this project would lx' ]-2 minutes and that this project would not eXll:'ncl present l):ltro] rOllles. No ;](1- ditionai p:)]jce pcn;ond will be required to providc' norlllal pro- teclive services to thc projl'Cl:. , "11](:, project is IXJLlIlded by two nXldways (Durom Avenuc and the il]lcy way), facilitiiling ilCCCSS '1m! visuol Control from jXltro] veldcles. AdditioniiJly, a private security [:>Cltrol service will be retained on a cominuing basis to provide Ilonna] pnJtectivc ,services, thus re- ducing the freCjuellcy necess'lry for public lXl]ice patrol. Ederellce I' A. Sitc Context Map, this [;cclion " " ...".,i " ' 925 Durant l'roj ect -."------"---- Growth M;1I1agl'menr Plan Submission (ce) (~hj1r]_CilrcFaci~}tic:~;, The eva]uc1tion is the pro';i"ion of a child care facility within the Projecl.. A child carl~ facility will be provided for this project, to be 10- cared at a grade level within the employee housing complex. Space requirement,; will cunfcnn to the IV1inimum I\ules and P.egulations for Child Care Centers' Color;ldo Stale Dep8 rtment of Soci.al Services. In addition to interior sp8ce ,1Ile1 outdoor plGY arCG pl'ovided for the project generated children (ages 1-8), the child Cilrc f2.cilily will bc lilro;e cnoll\!h ro ilbsorb certain of the needs of the im- b v mediCite neighl:orhooel. l\'ls. Terry Enel, Dir(;etor of the i\spcn Montessori School, will serve ;1S consu]tanl to this de!'lcnt of the pmjeCl, (del) Ilicyde/Pc:destrj;~J..::~hs The evaluation is the location of the project relRtive to pedestrian ilnel bicycle path sy~":ms. Within casy access of patl1 system,:, the ]ll'ojcct is: 65CJ ft. from the cxis:ing Ute j\vci1lle pedestri:ll1/lJicyelc trail; 450 ft. to Glory Hole Pa I'k; 1600 fl. to the clownlown pedestrian mall system, LinJdng to rhe city sidewalk ~;y'otcm, a sidewalk will lY2 provided by the project development along Durant Avenue. Hcfcrence A. Vicinity Map, this section B, Site Plan, Pl1ysical Design and Program Section .-....., -, "J - 925 Dunmt Project Growth Management 1'1<111 SUDmi ssion (ee) lkcycljl~g ~~'acilitie~~. T'he e\'aluati()!1 is the prol'i~,i()n of refuSl: recycling Llcilities in ' the pwject del'elopment. Snch facilities will be provided near the pinking :uea of the project, conveniently accec:sible to lx.1th OCCUJY1]1[S and pick up of the sep- arated refusc; by the recycle center I'chicle, Consisrant with the recommendation of Mr. Dennis llolmc's of the City l\ccycling Center the project will separate containers for p:lass, tin, aluminum, andncwSpapCl"S in a loc;]tion acce:isible to 8 parked 5 ton flatbed truck, 20 fed long, l\efercncc ^. Site Phlll, Pl1y::ical Design :md l'mgr:nil Section (ff) l?::c_sign l:~;:lll~l~;S ~.!: the J J:llKlic,1 Pj)('l~ The evaluation is the ability of the project to accommodatc safe, convenient movement fOl' handicapped persons. The site and buildil1\" clesi\!n will jJLTmit unoDstnletcclrflovement ,--) ~.' (fo)' a wheel cJElir confined person) from any parking space to the (6) lowccr level sLtlclio units. This is accomplished by walking sur- faces which Vim not cxccc,cl a ~;]ope of 1:15 (U.I3. C. requirement) Hetcrcnce ^. Site Plan, Physical fksi(':n anclProgl'arn Section (gg) Proximity to Commercial Support Facilities The evaluation is convenient walking distance from the Projecr to commercial support facilities. "....."" '"', .....'"' '-_." 9 2.'; 1~1I rilntJ::E~~c:':'L Growth Managcmcnt Plan Submission Thc project is convenieJ1[ly located ] ,~' blocks frol11 the City 1\1arketj Durant Mall ilnc1 "pproxim,1tcl{ 1600 feel from tlie t]owl1lown pedestrian mall system (5,~ minutes walking distance), Hefcrcnce A. Vicinity l\1ap, Ihis section , r--' ..~' ".--,...--,.,---...,--.' .-_.,_.~ ....-..".. ....-...~_._""... ,_........ ,,-'...._. ......-. _' _ _. _ .,.__ "'._*W._"_-' _... '_ ~'--...<-.-..- "'..~_ ".,., -.... ..... ~ ,. I 1 1 , .j I ] I I I , i , I 1 ,j 1 1 I I 'J\U-r.u.!D LDlkl---Lj -11------ ----,.-ch..:), '"'\ I'~~ rj=j r-~ (1'\rr:~lJ """'r\ll) . j _. f-":'~ : J JC~__-i U I'~ 0 ~ rr::1.j -"1 ~-- ~-~ ~d0(' P;'0ii~,':r.-> lCLD~lJNTI.t7W~T.:> --"f/l'! 11':'~'ill ~_~''':'-J1 1;;11] I~ :!j 1 I: , lLJJl c", J 1',-: JI 1 ~ I rr I'....J, I 1 - - L oj L 1 ~, , L _I. ,,_.___ j , 1 \.J\:=')l tllP SlKEtT - _ -~ _~___~ _ ~__~~______ __ _/--- --------yr-j------ -- r:YPt"vW I 11, P~~Wf A'IS"'!" ~l/('I r fn"~]1-.- ",r",i~/,'~, I/W11~~:c;,__:.'.==C> ~,"','H/::~~~ ::<~ ms, . I . l' J'r:';f'"] '11 F~" (I Jili(k:'/~t.,.../U1 L :"",,,\t_.J--f~_-:-~::~~~~i Ij ..L,t n__ l'"'-"";~i"\./ IJ r-EtJu~w l,eLlY -- ..... ,~,-..__,.J,,: __ '__, u,t..... A. L "....~,:/::......~ lV-!\W"',i':",'~ II '"'' "',,,~-ifrolH1r][K~Jn mE'1f~j~ .~ C!1AfrJU S,tA,!-~ -~~----_./ ""--~---~-------'-----'S\LVtKG!-o....' I W"'U'lliCT~--~==~:-:: - - --=---'~ l \ 1 j 1 , j , :1 1 j 1 1 1 1 1 j j I f' -T '",..,',,'" ~~'~7:,~ ". , , I L..._ ...'_U ____. ~_ _~. "..~,-,-._,_..~,.._., ,'___..__...... ...~ ....__....,.."..__..."... C'.--'. _...-....'--.~--..----.....- I l I ! ;' l ~ i. !; !; j" I "f: " " Site Conte);t r.._r------"\~_----..J o ~o ")0 :00 ~''\ (V) I ! ,-",;r'."r ""':.::;" ," ''',-1.".' ":.< '.~\_c::.,.~ :". ,. -,-_....,;.,......~_..._---~_.-'-'.-.....~ ---~,'~..,".. '-.-.,. .."-..._._~.. ~"'" ,-.... '-..,./ '-" 92S ) )urant Project Growth i\1 alwgemelll Plan ;;u!Jmission 1';1\1I'1'oYEE IIOUSINC The ev,l]uation is tlie p"'lTelltage of low ,1Ild moderate income housing unit s provided by tlie development pnJI'X)S,ll. 4S;z)-5C);~ of pnljeCl UBi", clesignated l,O\'1 Income' housing arc awarcled 12 point',;, The 925 DUl'illlt Project ii; the employ'.:" housing lX)J.tion of a complete GMP proposal which combines two (kvclopment locations (925 IJurant aBd SOO S. Calena) ,1 s thc tot:ll project submi);sion. The total projcct submisc)ion is comprisecl of 29 Iota] unit:, of whicli 16 units arc design,ltecl as single bcdnYlm condominiums ,md 13 units ,1S studio cmployee units. 1'lic project i" designed to pnlvide 12 employee units, located at 925 Durant, to the low income employee group at large and 1 crnpleJyee unit spccifically for managers [juarten; ,lttcnclant: to ;iOO South CalC'na conclom! niulll s. lis sl1cwm by the typiC1l unit plan on thisscction, each sludio un,il is approximately 425 s. 1'. i1l1cl is addition,]Uy SUPIX1HCd by common laundry, slorilge ,lnd ,by c ,rc J'aciliii<'s. Larger than nOl'll1:11 this slildio is desigl1L'd to accommodate c,liill'Cd liviiig SP,lClC for a mini- mum of 2 OCCl<]XlIIlS. U)'Xln receiving eM!' approval that pOrlicJlI of the project cOlllpl'ising ernployee housing would IK: irnmcc1ialcly constructed mid ilV8ilablc for occupailcy prior to Dccember, 1978. The cmployee unit mix and ]:ent stniCturc 1'01' this pl'oject is sub- mj ttcd ,I s l'oJ]ows: % 0[----- '- tut,d pwj ect Designatiol] units r~:. Unil S 13 4.s~Z, LolV Income TOlal r'lIllllUa] Tot,11 '1IIum,l!'- monthly . Income monthly Income rent/one I Group/ rcnt/two Croup/ occupalll CHch OCCU)Ylnts eelch toccupant OCCUlYlm ,-- --------- 1-.------ $175/mo. S700CJ/yr. S200/mo, S:fOOQLx,r:: * Annual income group calculated using :)()j~ of gross annual income allocated to housing cost (Planning Office Standard). .. # .- ~ l<'h.,./ --, '<"" 925 Duranr Project C l'(lwrh 1\1 anugement Pl;1I1 Submission The rental stnlCl.Ure for the employee units is designed to permit a nece.%ary low income ~;uppon gl'Oup to maintain affonlnblc housing within walking distnnce of m;ljor cmplo)'nwnt gcner;ltors in Aspen. Spending 30/(; of annu;ll income for rcnt a single occuixlnt making $7000/y1'. m;lY afford ;] [;tudio or, if sharing a studio, 2 persons milking $'1O()O/yr. each can afford a unit in this project. Assuming 1O()% double occupancy, the (13) uniu; pl'Oviclccl would house 26 low income employee;,'; wl1o,;e illll1ual income is S'1000/yr. or greater. This project is within casy walking dis!ilnce of alllJ13jor employ- ment, shopping ;Iml recreotionill (Iestinotions in Aspen. A tOl;11 of (12) points is anticipated under rhe housing scction for thi s projecr submi ssion. P.cfercnc',': A, Typiutl Unit Floor Plan; thi,; secrion B. Architectural Drawings; I~lysic;il Design ilnd Program Section